Sunsynk ACURE 8.0kW (Black) Single Phase Hybrid Inverter

  
By Sunsynk

Delivery available

Sunsynk Acure 8kW Black Single-Phase Hybrid Inverter

  • 8 kW single-phase hybrid inverter for solar PV, 48 V battery storage and backup-power applications.
  • Accommodates up to 16 kW PV access power through two independent MPPT trackers.
  • Supports lead-acid or lithium-ion batteries and offers up to twice rated off-grid power for 10 seconds.

Sunsynk Acure 8kW hybrid inverter for solar and battery storage

The black Sunsynk Acure 8kW Single-Phase Hybrid Inverter combines solar PV conversion, low-voltage battery charging and AC energy management in one IP65-rated enclosure. It is suitable for larger homes, farm buildings, workshops, offices and other single-phase sites where solar self-consumption and battery-backed loads are required.

With 8,000 W rated AC input/output active power, 190 A maximum battery charge and discharge current, and two MPPTs, the Acure 8kW provides a practical basis for a professionally designed solar-and-storage system. Installation and commissioning should be carried out by a qualified trusted partner. [file:76]

Key features

  • Two MPPTs: supports two PV tracker inputs, with two strings per tracker and up to 16,000 W PV access power.
  • 48 V battery connection: compatible with lead-acid or lithium-ion batteries across a 40–60 V battery voltage range.
  • Backup-power capability: 8 kW rated power and two-times-rated off-grid peak power for up to 10 seconds.
  • Efficient solar conversion: 97.6% maximum efficiency, 96.5% European efficiency and 99% MPPT efficiency.
  • Suitable for external locations: IP65 enclosure, intelligent air cooling and operation from -40°C to +60°C, with derating above +45°C.

Where to use

Use the Sunsynk Acure 8kW hybrid inverter in single-phase PV and battery installations for high-demand homes, agricultural buildings, workshops, small offices and light-commercial premises. The two MPPT inputs can accommodate separate array orientations where PV-string voltage and current limits are met.

It can be specified for solar self-consumption, battery charging, timed energy use and backup circuits. Battery capacity, backup loads, protection equipment, earthing, cable sizing and grid-notification requirements must be assessed for the individual site; Energian can provide UK expert support and help source a trusted installation partner. [web:77][file:76]

Technical specifications

Model SunC2-8.0LV01WB
Battery type Lead-acid or lithium-ion
Battery voltage range 40–60 V
Maximum charging current 190 A
Maximum discharging current 190 A
Lithium-ion charging strategy Self-adaption to BMS
Number of battery inputs 1
Maximum PV access power 16,000 W
Maximum PV input power 12,800 W
Maximum PV input voltage 500 V
Start-up voltage 125 V
MPPT voltage range 150–425 V
Rated PV input voltage 370 V
Maximum operating PV input current 32 A / 32 A
Maximum input short-circuit current 48 A / 48 A
Number of MPPT trackers / strings per MPPT 2 / 2+2
Rated AC input/output active power 8,000 W
Maximum AC input/output apparent power 8,800 VA
Peak power off-grid 2 times rated power, 10 seconds
Rated AC input/output current 36.4 A / 34.8 A
Maximum AC input/output current 40 A / 38.3 A
Maximum continuous AC passthrough, grid to load 50 A
Rated input/output voltage range 220 V / 230 V; 0.85Un–1.1Un
Grid connection form L/N/PE
Rated input/output grid frequency range 50 Hz: 45–55 Hz; 60 Hz: 55–65 Hz
Power factor adjustment range 0.8 leading–0.8 lagging
Total current harmonic distortion THDi <3% of nominal power
DC injection current <0.5% In
Maximum efficiency 97.6%
European efficiency 96.5%
MPPT efficiency 99%
Protection Integrated DC polarity reverse connection protection, AC output overcurrent protection, thermal protection, AC output overvoltage protection, AC output short-circuit protection, DC component monitoring, overvoltage load drop protection, ground fault current monitoring, optional arc fault circuit interrupter, power network monitoring, island protection monitoring, earth fault detection, DC input switch, DC terminal insulation impedance monitoring, residual current RCD detection
Surge protection level Type II DC, Type II AC
Display LCD / LED
Communication interface RS485 / RS232 / CAN
Monitoring mode GPRS / WiFi / Bluetooth / 4G / LAN optional
Operating temperature range -40°C to +60°C; derating above +45°C
Permissible ambient humidity 0–100%
Permissible altitude 2,000 m
Noise <30 dB
Ingress protection rating IP65
Inverter topology Non-isolated
Over-voltage category OVC II DC; OVC III AC
Cabinet size (W × H × D) 366 × 630 × 281.41 mm, excluding connectors and brackets
Weight 27.1 kg
Cooling Intelligent air cooling
Warranty 5 years; 10 years when installed with a Sunsynk battery
Grid regulation G98/G99, NRS 097-2-1, EN 50549-1
Safety and EMC standards IEC/EN 61000-6-1, IEC/EN 61000-6-2, IEC/EN 61000-6-3, IEC/EN 61000-6-4, IEC/EN 62109-1, IEC/EN 62109-2

Documents available for download

Shipping

Available for shipping to the UK, Ireland, Africa, the Caribbean and worldwide. If the shipping rate is not shown at checkout, contact us on +44 2080 640335 or info@energian.co.uk for a quote.

UK expert support

UK expert support is available for questions, product compatibility and system-design support. Contact Energian by phone, email or live chat, or visit our office for an in-person consultation.