Sunsynk ACURE 5.0kW (Black) Single Phase Hybrid Inverter

  
By Sunsynk

Sunsynk Acure 5kW Black Single-Phase Hybrid Inverter

  • 5 kW single-phase hybrid inverter for solar PV, 48 V battery storage and selected backup-load applications.
  • Supports up to 10 kW PV access power through two MPPT trackers, allowing flexible solar-array layouts.
  • Compatible with lead-acid and lithium-ion batteries, with BMS self-adaption for supported lithium battery systems.

Sunsynk Acure 5kW hybrid inverter for solar and battery storage

The black Sunsynk Acure 5kW Single-Phase Hybrid Inverter combines solar PV conversion, low-voltage battery charging and AC power management in an IP65-rated enclosure. It is suited to homes, farm buildings, workshops, small offices and light-commercial single-phase sites.

The unit provides 5,000 W rated AC input/output active power and up to 120 A battery charge or discharge current. Its two MPPT inputs support solar arrays across different roof orientations, subject to the stated PV voltage, current and string limits. [web:64]

Key features

  • Two MPPT trackers: supports two strings per MPPT and up to 10,000 W PV access power.
  • 48 V battery connection: suitable for lead-acid or lithium-ion batteries within a 40–60 V operating range.
  • Backup capability: delivers 5 kW rated AC power and up to two-times-rated off-grid peak power for 10 seconds.
  • Efficient conversion: maximum efficiency of 97.6%, European efficiency of 96.5% and MPPT efficiency above 99%.
  • Protected enclosure: IP65 rating, Type II AC and DC surge protection, and intelligent air cooling.

Where to use

The Sunsynk Acure 5kW Black Single-Phase Hybrid Inverter is appropriate for solar self-consumption and battery-storage systems at houses, outbuildings, agricultural buildings, small retail units, workshops and offices with a single-phase electricity supply.

It can form part of a battery-backed supply arrangement, but it is not an out-of-the-box installation. A trusted qualified partner should confirm battery compatibility, backup-load requirements, PV string design, earthing, protection and applicable G98/G99 grid-connection requirements. Energian can provide UK expert support for product selection and system design. [web:64][web:86]

Technical specifications

Model SunC2-5.0LV01WB
Battery type Lead-acid or lithium-ion
Battery voltage range 40–60 V
Maximum charging current 120 A
Maximum discharging current 120 A
Lithium-ion charging strategy Self-adaption to BMS
Number of battery inputs 1
Maximum PV access power 10,000 W
Maximum PV input power 8,000 W
Maximum PV input voltage 500 V
Start-up voltage 125 V
MPPT voltage range 150–425 V
Rated PV input voltage 370 V
Maximum operating PV input current 32 A / 32 A
Maximum input short-circuit current 48 A / 48 A
Number of MPPT trackers / strings per MPPT 2 / 2+2
Rated AC input/output active power 5,000 W
Maximum AC input/output apparent power 5,500 VA
Peak power off-grid 2 times rated power, 10 seconds
Rated AC input/output current 22.8 A / 21.8 A
Maximum AC input/output current 25 A / 24 A
Maximum continuous AC passthrough, grid to load 40 A
Rated input/output voltage range 220 V / 230 V; 0.85Un–1.1Un
Grid connection form L+N+PE
Rated input/output grid frequency range 50 Hz: 45–55 Hz; 60 Hz: 55–65 Hz
Power factor adjustment range 0.8 leading–0.8 lagging
Total current harmonic distortion THDi <3% of nominal power
DC injection current <0.5% In
Maximum efficiency 97.6%
European efficiency 96.5%
MPPT efficiency >99%
Protection Integrated DC polarity reverse connection protection, AC output overcurrent protection, thermal protection, AC output overvoltage protection, AC output short-circuit protection, DC component monitoring, overvoltage load drop protection, ground fault current monitoring, optional arc fault circuit interrupter, power network monitoring, island protection monitoring, earth fault detection, DC input switch, DC terminal insulation impedance monitoring, residual current (RCD) detection
Surge protection level Type II (DC), Type II (AC)
Display LCD + LED
Communication interface RS485 / RS232 / CAN
Monitoring mode GPRS / WiFi / Bluetooth / 4G / LAN (optional)
Operating temperature range -40°C to +60°C; derating above +45°C
Permissible ambient humidity 0–100%
Permissible altitude 2,000 m
Noise <30 dB
Ingress protection rating IP65
Inverter topology Non-isolated
Over-voltage category OVC II (DC), OVC III (AC)
Cabinet size (W × H × D) 366 × 630 × 281.41 mm, excluding connectors and brackets
Weight 27.1 kg
Cooling Intelligent air cooling
Warranty 5 years; 10 years when installed with a Sunsynk battery
Grid regulation G98/G99, NRS 097-2-1, EN 50549-1
Safety / EMC standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Documents available for download

Shipping

Available for shipping to the UK, Ireland, Africa, the Caribbean and worldwide. If the shipping rate is not shown at checkout, contact us on +44 2080 640335 or info@energian.co.uk for a quote.

UK expert support

UK expert support is available for product questions, battery compatibility and system-design requirements. Contact Energian by phone, email or live chat, or visit our office for an in-person consultation.