SolisStorage EverCore 120kWh Battery and 60kW Hybrid Inverter System

  
By Solis

Bulk Supply Quote

Delivery available

SolisStorage EverCore 120kWh Battery and 60kW Hybrid Inverter System

  • One outdoor cabinet holds 119.2kWh of usable LFP storage, a 60kW three-phase hybrid inverter and up to 100kW of solar input.
  • Keeps critical loads running in a grid outage, with backup switchover in under 10ms.
  • Built-in air conditioning plus layered fire suppression: aerosol, explosion relief valve and fire water inlet.

SolisStorage EverCore 120kWh battery and 60kW hybrid inverter system

The SolisStorage EverCore 120kWh battery and 60kW hybrid inverter system (EverCore-120kWh-60kW-NV) pairs a 120.6kWh LFP battery cabinet with a Solis S6-EH3P60K-H inverter. It stores solar or off-peak grid energy, cuts peak demand and backs up three-phase loads. Battery management, monitoring and connections for grid, load and a diesel generator are built in.

Key features

  • Six 20.1kWh battery packs built from 3.2V / 314Ah LFP cells, rated for 8,000 cell cycles (cell manufacturer data, 25°C, 0.5P, 70% SOH).
  • Rated at 60kW / 60kVA on-grid. Backup output can briefly reach 1.5× rated power for 10 seconds or 1.6× for 2 seconds.
  • Four MPPTs and 8 PV strings, 1,000V maximum input and a 150–850V MPPT range.
  • Off-grid parallel operation of up to 10 units, with a dedicated GEN port for a diesel generator.
  • SolisCloud app setup over Bluetooth, plus WiFi, LAN, CAN, RS485, DRM and dry contacts (4G optional).

Where to use

This system suits three-phase commercial and industrial sites. Examples include logistics depots, cold stores, farms, workshops, factories, schools and EV charging hubs.

Typical uses are solar self-consumption, peak shaving, time-of-use tariff shifting, backup for critical loads, and off-grid or weak-grid sites running alongside a generator.

Installation and site requirements

The system is not plug-and-play. The cabinet and inverter ship separately and are assembled on site. Lifting needs a crane or forklift rated for at least 3 tonnes. Energian can arrange design, installation and commissioning through trusted partners.

Install outdoors on a level, solid base at least 200mm high. Keep at least 1,200mm behind the cabinet and about 2,000mm clear in front. Grid connection needs DNO approval, and an external ATS is needed if you want a bypass. EverCore is not a UPS.

Solar panels, mounting, cabling, switchgear and grounding are not included. They can be quoted to suit your site.

SolisStorage EverCore 120kWh / 60kW technical specifications

Specification EverCore-120kWh-60kW-NV
System
Rated energy capacity 120.6kWh (manual: 120.576kWh)
Usable energy capacity 119.2kWh (30–35°C, 0.3C, 100% DOD, within one month of manufacture)
Nominal charging / discharging power 60kW / 60kW
Max. cycle rate 0.5P
Max. cycle efficiency 89% (cell test at 25 ±2°C, 0.5P, AC output 380 or 400Vac)
Dimensions (W × H × D) 1,250 × 2,030 × 1,540mm
Dimensions without inverter (W × H × D) 950 × 2,030 × 1,540mm
Weight 1,630kg (cabinet) + 73kg (inverter)
Operating temperature range -25 to +55°C (manual: charging 0 to +55°C, discharging -25 to +55°C)
Storage temperature range 0 to +40°C
Transportation temperature -30 to +55°C; humidity ≤85% (no condensation)
Operating humidity range ≤95% (non-condensing)
Max. operation altitude 4,000m (derating above 2,000m)
System temperature control mode Industrial-grade air-conditioning (cabinet); air cooling (pack); intelligent fan-cooling (inverter)
Fire suppression mode Default: aerosol, explosion relief valve, fire water inlet, audible and visual alarm. Optional: flammable gas detector, explosion relief panel, explosion-proof exhaust fan
Fire detection Smoke detector and temperature detector (standard); aerosol releases at 170 ±5°C cabinet temperature; DN65 fire water inlet connector
Ingress protection IP55 (cabinet) + IP66 (inverter)
Anti-corrosion class (battery cabinet) C4 / C5 (optional)
Anti-corrosion class (inverter) C5
Noise (rated operating condition) 70dB(A) at 1m
Lightning protection Type II (AC port), Type II (PV & battery)
Protection mode Anti-islanding protection, residual current detection, insulation resistance detection, AC overcurrent protection, AC cable connection protection
Auxiliary power supply 220Vac, approx. 2.3kW (taken from the inverter backup port)
Communication protocol (cabinet) TCP/IP, CAN, RS485
Certification standards (datasheet) IEC 62619, IEC 61000-6-2/4, IEC 62040, IEC 63056, IEC 62477, UN38.3
Compliance standards (manual) UN38.3, IEC 62619, IEC 60730-1, IEC 63056, IEC 62477-1, IEC 61000-6-2 / IEC 61000-6-4, UN3480
Battery
Cell type LFP 3.2V / 314Ah (EVE MB31, 5.6 ±0.2kg)
Cell cycle life 8,000 (cell manufacturer data at 25 ±2°C, 0.5P charge and discharge, SOH = 70%)
System battery configuration 1P120S
Rated voltage 384V
Operating voltage range 348–432V
Rated DC current 157A
Number of battery packs 6
Battery pack model PACK-1P20S-314-01
Battery pack capacity 20.1kWh
Battery pack rated voltage / range 64V / 58–72V
Battery pack charge and discharge rate ≤0.5C
Battery pack weight 138kg
Battery pack dimensions (W × H × D) 435 × 230 × 904mm
Battery pack ingress protection IP20
Balancing mode Passive cell balancing
Pack communications port CAN 2.0
Inverter
Inverter model S6-EH3P60K-H(21A)
Rated output power 60kW
Max. apparent output power (on-grid) 60kVA
Rated grid voltage 3/N/PE, 220V / 380V; 3/N/PE, 230V / 400V
Rated grid frequency 50Hz / 60Hz
AC grid frequency range 45–55Hz / 55–65Hz
Rated output current 91.2A / 86.6A
Max. apparent output power (off-grid) 1.5 × rated power, 10s; 1.6 × rated power, 2s
Back-up switch time <10ms
Power factor >0.99 (0.8 leading – 0.8 lagging)
THDi / THDv (at linear load) <2% / <3%
Max. usable PV input power 100kW
Recommended max. PV array size 100kW
Max. input voltage 1,000V (reduces above 2,000m: 981V at 3,000m, 925V at 3,500m, 875V at 4,000m)
Rated voltage 600V
Start-up voltage 180V
MPPT voltage range 150–850V
Max. input current 4 × 42A
Max. short circuit current 4 × 60A
MPPT number / max. input strings number 4 / 8
Communication Standard: WiFi + LAN + Bluetooth, CAN-BMS × 2, CAN-Parallel × 2, RS485-Meter, RS485, DRM, DI × 3, DO × 3. Optional: 4G
Max. parallel quantity (off-grid) 10
AC ports Grid, Backup (user load), GEN (diesel generator)
Thermal management (air conditioner)
Refrigerant R134a
Refrigerating / heating capacity 3,200W / 1,000W
Rated power (refrigerating / heating) 1,600W / 1,200W at 50Hz; 1,800W / 1,300W at 60Hz
Rated voltage / frequency 220Vac ±15% / 50/60Hz
Installation
Foundation Concrete or level ground, foundation height ≥200mm; load capacity 1.5 × n tonnes (n = number of units); 4 fixing points with M12 bolts
Clearances Back to wall ≥1,200mm; front to wall 2,000mm recommended; back to back ≥500mm; facing units ≥2,500mm; inverter side ≥500mm (follow local fire authority requirements)
Grounding Equipment continuity <0.1Ω; system grounding resistance ≤4Ω
Recommended grid cable L1/L2/L3/N 50mm²; PE 25mm²
Recommended generator cable 16mm² (A/B/C/N/PE)
Lifting Lifting equipment >3t, 4 cables >1m, acceleration ≤0.2g; forklift and crane load capacity ≥3,000kg
Supplied accessories Sun shade, left and right side panels, front panel, bottom panel, 10 × M6×12 stainless steel screws

Documents available for download

Shipping

Shipping is available to the UK, Ireland, Africa, the Caribbean and worldwide. If a shipping rate is not shown at checkout, call +44 20 8064 0335 or email info@energian.co.uk for a quote. Delivery, unloading and site access are agreed for each order.

UK expert support

Our UK team can help you size an EverCore system, plan the PV array, generator and grid connection, and arrange installation. Contact us by phone, email or live chat, or visit our office for an in-person consultation.