Dyness LS Series 6.0kW LV Hybrid Inverter Single Phase, 48V (D6.0K-LS)
- Solar, 48V battery storage, backup power and generator control in one wall-mounted IP66 unit.
- Keeps essential circuits running in a power cut, with automatic switchover in under 4ms.
- Scales up: run up to 16 units in parallel for on-grid and off-grid systems.
Dyness LS Series 6.0kW LV hybrid inverter
The Dyness LS Series 6.0kW LV hybrid inverter (model D6.0K-LS) is a single-phase inverter for 48V lithium-ion or lead-acid batteries. It powers your loads from solar, stores surplus energy and exports to the grid. It also supplies backup power during outages. Two MPPT trackers take up to 12,000W of PV, and the battery charges and discharges at up to 140A.
Key features
- 6,000VA rated grid output and 6,600VA continuous backup output, with a 12,000VA peak for 10 seconds for motor and compressor start-up.
- Up to twice the rated power in PV (12,000W), with 20A per MPPT input for modern 182/210mm high-power panels.
- The GEN port can run a generator with automatic start and stop by battery SOC. It can also run smart loads or AC coupling to an existing grid-tied inverter (micro-grid mode).
- Self-use, economic (time-of-use) and delay-charge modes, set through the colour touch-screen LCD or the app over Wi-Fi or LAN.
- Up to 97.6% maximum and 96.5% European efficiency, with an integrated PV DC switch, RCMU and Type III DC and AC surge protection.
Where to use
The LS 6.0kW suits homes, home offices, farm buildings, workshops and small commercial premises on a single-phase supply. Typical uses include higher solar self-consumption, cheap-rate battery charging and backup for lighting, IT, fridges and heating controls.
The generator port and parallel capability also suit off-grid and weak-grid sites, such as rural properties, cabins and remote sites. The IP66 rating and -30°C to 60°C operating range allow installation in garages, outbuildings or on outside walls.
Installation and grid connection
This inverter is not plug-and-play. It must be installed and commissioned by a qualified installer. That includes battery communication set-up, CT or meter fitting, and DNO notification under G98/G99 for grid-connected systems. Energian can arrange installation through trusted UK partners.
Order installation through our trusted partners and pay zero VAT. Installers can call 020 8064 0335 to join our authorised partner network.
Dyness LS Series 6.0kW (D6.0K-LS) technical specifications
| Specification | D6.0K-LS |
|---|---|
| Battery input data | |
| Battery type | Lead-acid / Li-ion |
| Battery voltage range | 40–60V |
| Nominal battery voltage | 48V |
| Max. charge / discharge current | 140A |
| Max. charge / discharge power | 6,000 / 6,600W |
| PV string input data | |
| Max. PV input power | 12,000W |
| Max. PV input voltage | 600V |
| Working voltage range | 50–550V |
| First feed-in voltage | 60V |
| MPPT range for nominal power | 180–500V |
| Nominal PV input voltage | 380V |
| Max. input current | 20 / 20A |
| Max. short-circuit current | 27 / 27A |
| No. of MPP trackers | 2 |
| Strings per MPP tracker | 1 |
| AC output data (on-grid port) | |
| Nominal power output to grid | 6,000VA |
| Max. power output to grid | 6,600VA (according to local grid regulation) |
| Max. power from grid | 12,000VA |
| Nominal output voltage | 220 / 230 / 240V, L/N/PE |
| Nominal output frequency | 50 / 60Hz |
| Nominal AC current to grid | 27.3 / 26.1 / 25A |
| Max. AC current to grid | 30A |
| Max. AC current from grid | 50A |
| Output power factor | Adjustable from 0.8 leading to 0.8 lagging |
| Output THDi (nominal power) | <3% |
| AC output data (back-up port) | |
| Max. continuous output power | 6,600VA |
| Peak output power | 12,000VA for 10s (only if PV and battery power are sufficient) |
| Max. output current | 30A |
| Nominal output voltage | 220 / 230 / 240Vac, L/N/PE |
| Nominal output frequency | 50 / 60Hz |
| Output THDv (linear load) | <3% |
| Switch time | <4ms |
| AC input data (generator port / load control port) | |
| Nominal input apparent power | 6,000VA |
| Max. input apparent power | 12,000VA |
| Max. AC input current | 50A |
| Nominal input voltage | 220 / 230 / 240V, L/N/PE |
| Nominal AC generator frequency | 50 / 60Hz |
| Efficiency | |
| Max. efficiency | 97.6% |
| European efficiency | 96.5% |
| Protection | |
| Anti-island protection | Integrated |
| PV insulation resistance detection | Integrated |
| PV reverse protection | Integrated |
| Residual current monitoring unit | Integrated |
| AC over-current / over-voltage protection | Integrated |
| DC switch (PV) | Integrated |
| Surge protection | DC Type III / AC Type III |
| Communication interface | |
| Battery BMS | CAN |
| EMS (Modbus) | RS485 |
| Meter (external) | RS485 |
| RCR / DRED | Yes (DI) |
| Remote shut-down | Yes (DI) |
| Dry contact | Yes (DO) |
| Cloud | Wi-Fi, LAN |
| Display / user interface | LED / LCD / app |
| Parallel operation | Max. 16 units, on-grid and off-grid |
| General data | |
| Operating temperature range | -30°C to 60°C |
| Relative humidity | 0–100% |
| Operating altitude | ≤3,000m |
| Cooling | Natural convection |
| Noise | <30dB |
| Weight | 17kg |
| Dimensions (W × H × D) | 501 × 586 × 193mm |
| Installation | Wall-mounted |
| Protection degree | IP66 |
| Certifications and standards | |
| Grid regulation | EN50549, NRS097, G98, G99, IEC61727, IEC62116 |
| Safety regulation | IEC/EN62109-1&2 |
| EMC | IEC/EN61000-6-1/2/3/4 |