Victron 5kVA 48V Off-Grid Energy System with 16.1kWh LiFePO₄ Battery and 8.0-11.0kW Generator - No Solar Required

   

Style

Delivery available

Victron 5kVA 48V Off-Grid Energy System with 16.1kWh LiFePO₄ Battery and 8.0–10.0kW Generator – No Solar Required

  • Run suitable off-grid loads without solar panels, using battery power between generator charging sessions.
  • Victron MultiPlus-II provides 230V pure sine wave power, rated at 5kVA / 4kW continuously at 25°C.
  • Dyness PowerBrick Plus storage provides 16.07kWh nominal and 15.27kWh usable battery energy, paired with a separately specified 8.0–11.0kW-class generator.

Off-grid battery and generator power without solar

This Victron 5kVA off-grid energy system combines a MultiPlus-II 48/5000/70-50 inverter-charger with a Dyness PowerBrick Plus LiFePO₄ battery and a selected generator in the 8.0–11.0kW class. The generator supports connected loads and recharges the battery through the inverter-charger. When it stops, suitable loads continue to run from stored energy without requiring solar panels.

Key features

  • No solar required: suitable where shading, limited roof space, seasonal operation or site restrictions make a solar array impractical.
  • Battery operation between charging sessions: run suitable loads without keeping the generator operating continuously. Actual generator hours depend on energy demand and charging requirements.
  • Managed generator loading: PowerControl limits AC input demand, while PowerAssist can supplement an accepted generator supply with battery power when correctly configured.
  • Dyness lithium storage: 314Ah LFP battery with IP65 protection, CAN/RS485 communication, Wi-Fi/app monitoring and a built-in aerosol fire-extinguishing unit.
  • Optional system monitoring: add a suitable Victron GX device for battery integration, system visibility and remote access through the free Victron VRM platform.

Where to use

Consider this system for remote offices, rural workshops, cabins, agricultural outbuildings, seasonal accommodation and selected logistics-site equipment where grid connection or solar generation is unavailable or unsuitable.

Assess daily energy consumption, simultaneous loads and motor-starting currents before specifying the package. The inverter provides 4kW continuous battery-powered output at 25°C; choosing an 8.0–11.0kW generator does not increase that battery-only rating.

Greater generator capacity can provide additional headroom for simultaneous loads and charging, but available power depends on its continuous rating, outlet limits, phase configuration and the final electrical design. Do not assume a generator’s total three-phase rating is available to this single-phase inverter.

How the system works

With the generator stopped, the inverter supplies suitable loads from the battery. When an acceptable generator supply is connected, the MultiPlus-II transfers to AC supply and uses available capacity for battery charging within the configured limits.

The 70A battery charger sets the maximum inverter charging current. A larger generator does not increase charging beyond this limit. PowerAssist is a managed battery-support function, not a guarantee that generator and inverter nameplate ratings can simply be added together.

No solar required does not mean no energy input is required: generator fuel supplies the energy needed to replenish the battery. No fixed runtime, recharge time or fuel-saving percentage is claimed.

Proposed package contents

Installation and commissioning

This is not a plug-in installation. A qualified electrician must design the generator connection, earthing and protective arrangements, battery cabling, isolation and load circuits. Energian can assist with installation through trusted partners.

Dyness lists Victron among compatible inverter brands. Confirm the exact inverter, battery firmware, communication protocol, cable pinout and GX requirements before commissioning. Keep charging and discharge settings within the battery manufacturer’s limits and disable lead-acid equalisation.

Automatic generator starting is not assumed. It requires a compatible generator and a correctly engineered control interface. Operate a combustion generator outdoors, away from doors, windows and air intakes; never run it inside the battery or inverter enclosure.

Technical specifications

Inverter figures follow the attached Victron MultiPlus-II datasheet, using the 48/5000/70-50 column. Battery figures follow the attached Dyness PowerBrick Plus datasheet, version 20251210-EN. Generator-specific figures will be added when the model is selected.

Specification Value
System configuration
System type Single-phase, generator-charged off-grid system
Solar requirement No solar panels required 
Inverter-charger Victron MultiPlus-II 48/5000/70-50, 230V
Battery model Dyness PowerBrick Plus
Battery chemistry LiFePO₄ / lithium iron phosphate
Nominal battery voltage 51.2V; 48V-class system
Nominal battery capacity 314Ah
Nominal battery energy 16.07kWh; approximately 16.1kWh
Usable battery energy 15.27kWh
Generator selection 8.0–11.0kW-class generators
Victron: inverter output
Continuous apparent output at 25°C 5,000VA
Continuous active output at 25°C 4,000W
Continuous active output at 40°C 3,700W
Continuous active output at 65°C 3,000W
Peak inverter power 9,000W
Output voltage 230V AC ±2%
Output frequency 50Hz ±0.1%
Output waveform Pure sine wave
DC input-voltage range 38–66V DC
Maximum inverter efficiency 96%
Zero-load consumption 18W
Zero-load consumption in AES mode 12W
Zero-load consumption in Search mode 2W
Maximum apparent feed-in power 5,000VA 
AC transfer time Less than 20ms
Victron: generator input and charging
AC input-voltage range 187–265V AC
AC input-frequency range 45–65Hz
Maximum AC input current 50A
Transfer-switch rating 50A
Maximum battery charging current 70A
PowerControl Adjusts charging demand to respect the configured AC input-current limit
PowerAssist Allows battery power to supplement an accepted AC input when enabled and correctly configured
AC output 1 Main inverter-backed output
AC output 2 Auxiliary output, available only when accepted AC input is present
Programmable relay Configurable for general alarm, DC undervoltage or generator start/stop signalling
Relay AC contact rating 230V AC / 4A
Relay DC contact rating 4A up to 35V DC; 1A up to 60V DC
Victron: controls, enclosure and environment
VE.Bus communication System integration, remote monitoring and supported parallel/three-phase configurations
General-purpose communication ports 2
Remote on/off Supported
Optional external AC current sensor 50A or 100A, as appropriate to the configuration
Remote monitoring Cerbo GX 
Remote platform Victron VRM
Local configuration VEConfigure with suitable interface
Cooling Fan-assisted
Operating temperature −40°C to +65°C; output derating applies
Maximum humidity 95%, non-condensing
Enclosure material and colour Steel, blue RAL 5012
Inverter ingress protection IP22
Battery terminals M8 bolts
AC terminals Screw terminals, 13mm² / 6AWG
Inverter dimensions, H × W × D 565 × 320 × 149mm 
Inverter weight 30kg
Protection functions Output short circuit, overload, high/low battery voltage, overtemperature, external 230V at inverter output and excessive DC input ripple
Safety references EN-IEC 60335-1; EN-IEC 60335-2-29; EN-IEC 62109-1; EN-IEC 62109-2
Emission and immunity references EN 55014-1; EN 55014-2; EN-IEC 61000-3-2; EN-IEC 61000-3-3; IEC 61000-6-1, -6-2 and -6-3
Dyness PowerBrick Plus: electrical performance
Nominal energy 16.07kWh
Usable energy 15.27kWh
Nominal capacity 314Ah
Nominal voltage 51.2V
Operating-voltage range 44.8–57.6V
Recommended charging/discharging rate 0.45C / 140A
Maximum charging rate 0.64C / 200A
Maximum discharging rate 0.64C / 200A
Peak discharge current at 25°C 300A for 2 minutes
Recommended charge/discharge power 7.168kW, battery-side rating
Maximum charge power 10.24kW, battery-side rating
Maximum discharge power 10.24kW, battery-side rating
Depth of discharge 95%
Dyness PowerBrick Plus: construction and environment
Battery chemistry LiFePO₄
Ingress protection IP65
Charging-temperature range 0°C to +55°C
Charging-temperature range with optional heating −20°C to +55°C
Discharging-temperature range −20°C to +55°C
Battery dimensions, W × D × H 435 × 235 × 850mm
Battery net weight 119kg
Installation methods Floor-mounted or wall-mounted
Safety protection Built-in aerosol fire extinguisher; does not eliminate fire risk or replace installation safeguards
Communication CAN / RS485
User interface Wi-Fi and app
Parallel expansion Up to 50 compatible units
Cycle life ≥8,000 cycles
Cycle-life test conditions 0.2C charging/discharging, 25°C, 95% depth of discharge, 70% end-of-life capacity
Battery warranty 10 years
Certification and safety references UN38.3; IEC62619
Battery datasheet revision 20251210-EN
Generator selection and final integration
Proposed generator range 8.0–11.0kW class; select one model for the final package
Required electrical configuration Compatible 230V single-phase output with sufficient continuous power at the selected outlet
Generator rating basis Continuous and maximum ratings must be identified separately for each option.
Three-phase generator restriction A generator’s total three-phase output is not automatically available on one phase. Confirm its approved single-phase capability.
AC input current budget The MultiPlus-II permits up to 50A input, but the commissioned limit must not exceed the generator outlet, cable or protective-device rating.
Available charging power Shared with connected loads and limited by the 70A inverter charger, battery settings and generator capability
Fuel, tank, runtime, noise and dimensions Specify from the selected generator’s manufacturer documentation; not inferred from output rating
Automatic start/stop Optional project feature requiring a compatible generator and approved interface; not assumed included
Commissioning checks Generator voltage/frequency acceptance, load steps, charging demand, PowerAssist operation, battery communication and protection coordination
Combined inverter and battery weight 149kg calculated from the supplied datasheets; excludes generator, cables, enclosure and installation hardware
Complete system weather protection No single overall IP rating claimed. Each component requires an appropriate installation location.