SolaX X3-Ultra 30.0kW HV 3‑Phase Hybrid Inverter
Key benefits
- 30kW three‑phase C&I hybrid inverter for larger commercial and industrial systems combining PV generation and high‑voltage lithium batteries.
- Supports up to 200% PV oversizing, 110% AC output and 200% EPS overload for 10 seconds, helping manage demanding site loads and short peaks.
- IP66‑rated, with Type II surge protection on AC and DC sides plus optional AFCI, suited to exposed plant rooms, rooftops and service yards.
Brief description
The SolaX X3‑Ultra 30.0kW HV 3‑Phase Hybrid Inverter is designed for three‑phase commercial and industrial projects that need a single platform for PV, battery storage and backup power. It offers smart management features including UPS‑level switchover, built‑in shadow tracking and smart load control, making it a practical choice for logistics hubs, small factories, retail sites and mixed‑use buildings. With support for up to 10 units in parallel and microgrid/generator functions, it can scale with project needs and integrate into wider energy strategies.
Key features
- Three‑phase C&I hybrid inverter with 30kW rated output and EPS backup operation when paired with batteries.
- Max. 10 inverters in parallel for both on‑grid and off‑grid operation, plus microgrid and generator support for versatile system design.
- Max. 36A PV input per MPPT across three trackers, optimised for high‑power solar panels and flexible string layouts.
- Single‑unit UPS‑level switchover time below 10ms, with loads response time within 0.3s for smart loads such as heat pumps and EV chargers.
- VPP‑ready with compatibility options including OpenADR, IEEE2030.5, FCAS and API (feature to be upgraded in future firmware).
Technical specifications
PV input
| Max. recommended PV array power |
60 kWp (X3‑ULT‑30K) |
| Max. PV input voltage |
1000 V (①) |
| Rated PV input voltage |
600 V |
| Operation voltage range |
120 ~ 950 V |
| MPPT voltage range |
160 ~ 950 V (②) |
| Start-up voltage |
200 V |
| No. of MPP trackers / strings per MPP tracker |
3 / (2 / 2 / 2) (X3‑ULT‑30K) |
| Max. input current per MPPT |
36 A / 36 A / 36 A (X3‑ULT‑30K) |
| Max. input short circuit current per MPPT |
45 A / 45 A / 45 A (X3‑ULT‑30K) |
AC input & output (on‑grid)
| Rated output power |
30000 W (AS4777 29999 W, VDE4105 29900 W) (X3‑ULT‑30K) |
| Rated output current |
43.5 A (X3‑ULT‑30K) |
| Max. output apparent power |
30000 VA (AS4777 29999 VA, VDE4105 29900 VA) (X3‑ULT‑30K) |
| Max. output continuous current |
43.5 A (X3‑ULT‑30K) |
| Rated AC voltage |
3 / N / PE, 220 / 380 V; 3 / N / PE, 230 / 400 V |
| Max. AC input apparent power |
30000 VA (X3‑ULT‑30K) |
| Max. AC input current |
43.5 A (X3‑ULT‑30K) |
| Rated AC frequency |
50 Hz / 60 Hz |
| Adjustable power factor range |
~ 1 (0.8 lagging to 0.8 leading) |
| THDi (rated power) |
< 3% |
Battery
| Battery type |
Lithium |
| Battery voltage range |
120 ~ 800 V (③④) |
| Max. charge / discharge current |
60 A (30 A × 2) |
EPS (off‑grid) output (with battery)
| Rated EPS output voltage, frequency |
230 V / 400 V, 50 Hz / 60 Hz |
| Rated EPS output power |
30000 VA (30K) |
| Peak EPS output power |
2 times of rated power, 10 s |
| Switchover time |
< 10 ms |
Efficiency
| Max. efficiency |
98.0% |
| European efficiency |
97.7% |
Environment limit
| Ingress protection |
IP66 |
| Operation temperature range |
-35 ~ 60°C (> 45°C derating) |
| Max. operation altitude |
3000 m |
| Relative humidity |
0 ~ 100% RH (condensing) |
| Overvoltage category |
Mains: III, Battery: II, PV: II |
General
| Dimensions (W × H × D) |
696 × 526 × 240 mm |
| Net weight |
47 kg |
| Cooling concept |
Smart air cooling |
| Communication interfaces |
Meter (RS‑485), DI × 2, DO × 1, Modbus |
| Power consumption (night) |
< 5 W |
| Topology |
Non‑isolated |
| Certifications |
VDE4105, G99, AS4777, EN50549, CEI 0‑21, IEC61727, PEA/MEA, NRS‑097‑2‑1, RD1699, TOR |
Protection
| Protections |
Over / under voltage protection, DC reverse‑polarity protection, Residual current detection, Over temperature protection, DC isolation protection, Grid monitoring, DC injection monitoring, Back feed current monitoring |
| Active anti‑islanding method |
Frequency shift |
| Surge protection |
DC: Type II, AC: Type II |
| Arc-fault circuit interrupter (AFCI) |
Optional |
Manufacturer notes
| Note ① |
The maximum input voltage is the upper limit of the DC voltage. Any higher input DC voltage would probably damage inverter |
| Note ② |
Input voltage exceeding the MPPT voltage range may triggers inverter protection |
| Note ③ |
Compatible with a minimum of 3 units of HS Series batteries, but if the total voltage of the 3 batteries is less than 127V and there is no PV input, the system will not able to startup |
| Note ④ |
When the voltage is below 180V, the inverter will limit the battery current to less than 20A |
Shipping
Shipping is available to the UK, Ireland, Africa, the Caribbean and worldwide. If the shipping rate is not shown at checkout, please contact us on +44 2080640335 or info@energian.co.uk for a tailored shipping quote.
UK expert support
UK expert support is available to help with system design, product selection and technical questions for the SolaX X3‑Ultra 30.0kW HV 3‑Phase Hybrid Inverter. For commercial and industrial projects we recommend installation and commissioning through our trusted partners, ensuring compliance with local grid codes and safe integration of PV, batteries, backup loads and generators.
You can contact us via phone, email or live chat, or visit our office for an in‑person consultation on your project requirements and hybrid system configuration.
Documents available for download
This product requires a quantity of 3 minimum.