Könner & Söhnen KS 7000E Petrol Generator

  

The Könner & Söhnen KS 7000E is a single-phase petrol generator delivering 5.0kW rated power and 5.5kW maximum power at 230V. It combines manual and electric starting, AVR voltage regulation, a 25-litre steel fuel tank and two useful AC outlet formats for backup, workshop and site power.

Free delivery to mainland Great Britain only. For help checking load or socket requirements, contact Energian before ordering.

At a glance

Könner & Söhnen KS 7000E physical specifications infographic showing 76.2kg net weight and 680 × 545 × 550mm dimensions
Könner & Söhnen KS 7000E technical specifications infographic showing 5.0kW rated output, 5.5kW maximum output and 17-hour runtime
Rated / maximum output 5.0kW / 5.5kW
Output 230V, 50Hz, single phase, AVR regulated
AC sockets 1 × UK 13A household socket; 1 × 32A Commando (CEE) socket — both 230V.
Starting Manual and electric
Petrol tank / runtime 25 litres / approximately 17 hours at 50% load
Net weight 76.2kg

Why choose the KS 7000E?

  • Useful single-phase output: 5.0kW rated and 5.5kW maximum power at 230V.
  • Two starting methods: electric start for convenience, with a manual recoil starter as an alternative.
  • AVR regulation: the automatic voltage regulator helps maintain a stable conventional generator output as the load changes.
  • Long petrol runtime: the 25-litre steel tank provides approximately 17 hours at 50% load under the manufacturer's stated conditions.
  • Clear operating information: the LED display shows voltage, frequency and operating hours for load monitoring and maintenance planning.
  • Durable construction: a synchronous alternator with copper winding and rubber anti-vibration feet support dependable operation.
  • Optional mobility: the separately available KS 7 KIT adds two wheels, two support legs, mounting hardware and two handles.

Power, fuel and connections

Plan your load

Use the 5.0kW rated output for load planning and allow for motor starting surges. For longer service life, the manufacturer recommends continuous loads no higher than 80% of rated output: 4.0kW.

Choose the correct outlet

The UK 13A household and 32A Commando (CEE) sockets are both 230V. Match the appliance, plug, cable, protective device and total load to the intended socket.

Conventional AVR output

This is an AVR-regulated conventional generator, not an inverter generator. Check the power-quality requirements of sensitive electronics before connecting them.

Technical specifications

Electrical output and connections
Rated / maximum output 5.0kW / 5.5kW
Voltage / frequency / phase 230V / 50Hz / single phase
Power factor 1
Maximum current 23.91A
Voltage regulation Automatic voltage regulator (AVR)
AC sockets 1 × UK 13A household socket; 1 × 32A Commando (CEE) socket — both 230V.
DC output 12V / 8.3A
Display Voltage, frequency and operating hours
Built-in ATS No
Engine and fuel
Fuel Petrol
Engine KS 390; single-cylinder, four-stroke, air-cooled
Displacement / power 389cm³ / 13hp (9.56kW)
Starting system Manual / electric
Petrol tank capacity 25 litres
Average runtime at 50% load Approximately 17 hours
Engine oil capacity 1.1 litres
Recommended oil SAE 10W-30 or SAE 10W-40 four-stroke engine oil
Emissions standard EURO 5
Size, weight and construction
Sound pressure / sound power 70dB(A) at 7m / 95dB(A) LWA
Protection rating IP23M
Alternator winding Copper
Product dimensions (L × W × H) 680 × 545 × 550mm
Packed dimensions (L × W × H) 700 × 545 × 590mm
Net / packed weight 76.2kg / 78.6kg

Runtime varies with load, fuel quality, weather, altitude and generator condition. Sound pressure at a stated distance and sound power are different measurements and should not be compared directly.

What's included

  • KS 7000E petrol generator
  • English operating instructions
  • Spark-plug wrench
  • Starter keys for the electric-start system

Engine oil, petrol, appliance leads and the optional KS 7 KIT transport set are supplied separately.

Before first use

Add engine oil and petrol before starting. The generator is supplied without either. Fill and check the 1.1-litre crankcase using SAE 10W-30 or SAE 10W-40 four-stroke oil, then add unleaded petrol rated 90-95 octane with no more than 10% ethanol.

Charge the starter battery and connect the generator to a suitable earth as instructed. The manual advises charging the battery before commissioning or allowing the generator to run for at least one hour at 50% load on its first start. Keep connected loads below 50% of rated output during the first 20 operating hours, then change the oil.

Operate outdoors, away from doors, windows and air intakes. Exhaust contains carbon monoxide. Keep the generator dry and follow the manual's clearance, refuelling, electrical protection and maintenance instructions. IP23M does not make it suitable for operation in rain.

Manuals and downloads

Warranty

Manufacturer's warranty: 1 year or 1,000 operating hours, whichever comes first, from the date of purchase.

The warranty covers manufacturing defects, subject to the manufacturer's warranty conditions. Retain your proof of purchase and any completed warranty documentation supplied with the generator. For help with a warranty claim, contact Energian with your order number, generator serial number and a description of the fault.

Frequently asked questions

Is the KS 7000E an inverter generator?

No. It is a conventional synchronous generator with AVR voltage regulation. If your equipment specifically requires pure sine-wave inverter output, contact Energian for a suitable inverter model.

Can it start automatically during a power cut?

No. The KS 7000E has manual and electric starting but no built-in ATS. The similarly named ATS variant is a different model.

Are wheels and handles included?

No. The optional KS 7 KIT is sold separately and includes two wheels, two support legs, mounting hardware and two handles.

How long will it run on a tank?

The manufacturer's figure is approximately 17 hours at 50% load. Actual runtime varies with load, fuel, weather, altitude and generator condition.

Can I use it in rain?

No. Operate it outdoors for ventilation, but protect it from rain, snow and moisture in accordance with the owner's manual.

Energian support

For help choosing a generator or checking load and connection requirements, contact Energian on 020 8064 0335 or info@energian.co.uk. For after-sales support, have your order number and generator serial number ready.