{"product_id":"zero-transfer-time-ups-iconica-6kw-48v-inverter-charger-and-4x-fogstar-3-84kwh-12v-lifepo4-batteries","title":"Zero Transfer Time UPS - ICONICA 6kW 48V Inverter-Charger and 4x Fogstar 3.84kWh 12V LiFePO4 Batteries","description":"\u003cdiv style=\"font-family: Helvetica,Arial,sans-serif; color: #333; line-height: 1.65; font-size: 18px; max-width: 1000px; margin: 0 auto;\"\u003e\n\u003ch1 style=\"font-size: 32px; line-height: 1.25; text-align: center;\"\u003e\u003cstrong\u003eZero Transfer Time UPS – ICONICA 6kW 48V Inverter-Charger with 4 × Fogstar Drift 3.84kWh LiFePO4 Batteries\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cul style=\"font-size: 18px; padding-left: 24px;\"\u003e\n\u003cli\u003eKeep selected business equipment powered during a mains outage, with 0ms transfer from AC mode to battery mode when correctly configured.\u003c\/li\u003e\n\u003cli\u003eSupply up to 6,000W of continuous pure sine wave power from a lithium battery bank with 15.36kWh nominal storage.\u003c\/li\u003e\n\u003cli\u003eBuilt-in inverter Wi-Fi, battery Bluetooth monitoring and an integrated MPPT controller supporting up to 6,000W of compatible solar input.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003e6kW zero transfer time UPS with Fogstar lithium storage\u003c\/h2\u003e\n\u003cp\u003eThis zero transfer time UPS pairs an ICONICA IC2-ZT6000-48 inverter-charger with four Fogstar Drift 12.8V 300Ah LiFePO4 batteries. Connected in series, the batteries form a 51.2V nominal, 300Ah bank for a 48V-class system. The package is intended for professionally designed essential-load circuits, with final battery compatibility and commissioning settings confirmed before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis inverter has the ability to be \u003c\/span\u003e\u003cstrong\u003econnected in parallel \u003c\/strong\u003e\u003cstrong\u003ewith additional identical units \u003c\/strong\u003e\u003cspan\u003e(maximum of 8 further inverters), offering the possibility of large-scale system expansion, with up to 54kW of power handling capability and up to 138.24kWh battery storage capacity. Once connected in parallel, there is the option for 3-phase operation (ideal if the system is being used to power industrial grade equipment and machinery run on 3 phase). Each inverter connected in the system will require a \u003c\/span\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/www.energian.co.uk\/products\/parallel-connection-kit-for-iconica-48v-kms-or-zt-series-hybrid-pure-sine-wave-inverters\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" target=\"_blank\"\u003eparallel connection kit\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e \u003c\/span\u003e(sold separately).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eKey features\u003c\/h2\u003e\n\u003cul style=\"padding-left: 24px;\"\u003e\n\u003cli\u003eContinuity for sensitive loads: 0ms AC-to-battery transfer. Inverter-to-bypass transfer is typically 4ms, so operating-mode selection matters.\u003c\/li\u003e\n\u003cli\u003e6kVA\/6kW pure sine wave output: suitable for assessed single-phase essential loads within the inverter and battery limits.\u003c\/li\u003e\n\u003cli\u003e15.36kWh nominal lithium storage: four Fogstar Drift 300Ah batteries, each rated at 3,840Wh, with individual battery management systems.\u003c\/li\u003e\n\u003cli\u003eFlexible charging: up to 120A solar charging or 120A mains charging, with the combined charging limit configured for the battery bank.\u003c\/li\u003e\n\u003cli\u003eSeparate monitoring: inverter Wi-Fi monitoring and Fogstar battery Bluetooth monitoring. Direct battery-to-inverter BMS communication is not assumed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eWhere to use\u003c\/h2\u003e\n\u003cp\u003eConsider this system for assessed essential-load circuits serving logistics offices, commercial workstations, network equipment, CCTV recorders, access control and selected small-server installations. Check total running power, starting loads and the required backup duration before specifying the package.\u003c\/p\u003e\n\u003cp\u003eThis is a single-phase system for selected circuits, not a complete factory or warehouse backup supply. Specialist medical, life-safety and other critical applications require a separate suitability assessment.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eSystem contents and installation\u003c\/h2\u003e\n\u003cul style=\"padding-left: 24px;\"\u003e\n\u003cli\u003e1 × ICONICA IC2-ZT6000-48 6kW 48V-class zero transfer time inverter-charger.\u003c\/li\u003e\n\u003cli\u003e4 × Fogstar Drift 12.8V 300Ah LiFePO4 batteries, using the 250A-BMS configuration specified for this draft.\u003c\/li\u003e\n\u003cli\u003e1 x Mersen DC Fused Disconnect 2-pole NH1 fuse size 250ADC max\u003c\/li\u003e\n\u003cli\u003eRequired cables, battery interlinks, fuses, AC protection and any enclosure included.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis system is not ready to use straight out of the box. A qualified electrician must design the battery connections, protection, isolation, earthing and essential-load circuits. Ask Energian about installation through trusted partners.\u003c\/p\u003e\n\u003cp\u003eFogstar permits up to four of these Drift batteries in series. Before assembly, confirm the exact supplied battery revision, follow Fogstar’s initial charging and balancing procedure, and verify ICONICA operation with the proposed battery bank. \u003c\/p\u003e\n\u003cp\u003eSet charging voltage, charge-current limits and low-voltage protection for the Fogstar batteries; do not use an AGM profile by default. Disable lead-acid equalisation and do not select a communications-based lithium profile unless the battery protocol and wiring are confirmed compatible.\u003c\/p\u003e\n\u003cp\u003eThe 15.36kWh figure is nominal stored DC energy, not guaranteed usable AC energy. Runtime depends on load, inverter consumption, operating limits, temperature and battery condition. A BMS protection trip can interrupt supply even though the inverter’s normal AC-to-battery transfer is specified at 0ms.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eTechnical specifications\u003c\/h2\u003e\n\u003cp\u003eInverter figures below follow the supplied IC2-ZT6000-48 datasheet. Battery figures follow the Fogstar Drift 12V 300Ah 250A specification. Calculated bank figures are identified separately. Different Fogstar generations must not be substituted without checking their specifications.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 17px; text-align: left;\" border=\"1\" cellpadding=\"10\"\u003e\n\u003cthead style=\"background: #f2f3f5;\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width: 55%;\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f2f3f5; text-align: left;\"\u003eSystem configuration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter model\u003c\/td\u003e\n\u003ctd\u003eICONICA IC2-ZT6000-48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter output rating\u003c\/td\u003e\n\u003ctd\u003e6,000VA \/ 6,000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery model used for this draft\u003c\/td\u003e\n\u003ctd\u003eFogstar Drift 12V 300Ah, 250A-BMS configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery quantity\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery chemistry\u003c\/td\u003e\n\u003ctd\u003eLithium iron phosphate, LiFePO4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBank configuration\u003c\/td\u003e\n\u003ctd\u003eFour batteries in series; one 48V-class string\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal voltage per battery\u003c\/td\u003e\n\u003ctd\u003e12.8V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal bank voltage — calculated\u003c\/td\u003e\n\u003ctd\u003e51.2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity per battery\u003c\/td\u003e\n\u003ctd\u003e300Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal energy per battery\u003c\/td\u003e\n\u003ctd\u003e3,840Wh \/ 3.84kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal bank energy — calculated\u003c\/td\u003e\n\u003ctd\u003e15,360Wh \/ 15.36kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal energy at an 80% discharge allowance — calculated\u003c\/td\u003e\n\u003ctd\u003e12.288kWh before inverter losses and operating restrictions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery-only weight — calculated\u003c\/td\u003e\n\u003ctd\u003e104kg, using 26kg per battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombined component weight — calculated\u003c\/td\u003e\n\u003ctd\u003e119kg using the inverter datasheet weight; excludes cables, protection devices, enclosure and packaging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f2f3f5; text-align: left;\"\u003eInverter: grid input\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal input voltage\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage range\u003c\/td\u003e\n\u003ctd\u003e110–280V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput frequency\u003c\/td\u003e\n\u003ctd\u003e50Hz \/ 60Hz, automatic sensing, ±4Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput power factor\u003c\/td\u003e\n\u003ctd\u003e≥0.98 at nominal voltage and 100% load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput-current total harmonic distortion, THDi\u003c\/td\u003e\n\u003ctd\u003e≤10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput and charging priorities\u003c\/td\u003e\n\u003ctd\u003eConfigurable AC\/solar priority through the LCD settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f2f3f5; text-align: left;\"\u003eInverter: AC output and transfer\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput waveform\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC voltage regulation, line and battery modes\u003c\/td\u003e\n\u003ctd\u003e230V AC ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSynchronised frequency range\u003c\/td\u003e\n\u003ctd\u003e46–54Hz or 56–64Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery-mode output frequency\u003c\/td\u003e\n\u003ctd\u003e50Hz ±0.1Hz or 60Hz ±0.1Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput harmonic distortion with linear load\u003c\/td\u003e\n\u003ctd\u003e≤3% THD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput harmonic distortion with non-linear load\u003c\/td\u003e\n\u003ctd\u003e≤5% THD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC-mode to battery-mode transfer\u003c\/td\u003e\n\u003ctd\u003e0ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter-to-bypass transfer\u003c\/td\u003e\n\u003ctd\u003e4ms typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero-transfer qualification\u003c\/td\u003e\n\u003ctd\u003eApplies to the specified AC-to-battery transition;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f2f3f5; text-align: left;\"\u003eInverter efficiency\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine-mode efficiency\u003c\/td\u003e\n\u003ctd\u003e94%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eECO-mode efficiency\u003c\/td\u003e\n\u003ctd\u003e98%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery-mode efficiency\u003c\/td\u003e\n\u003ctd\u003e92%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f2f3f5; text-align: left;\"\u003eInverter: battery and charging\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery-voltage range\u003c\/td\u003e\n\u003ctd\u003e40–62V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListed floating charge voltage\u003c\/td\u003e\n\u003ctd\u003e54V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvercharge protection\u003c\/td\u003e\n\u003ctd\u003e62V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum AC charging current\u003c\/td\u003e\n\u003ctd\u003e120A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum solar charging current\u003c\/td\u003e\n\u003ctd\u003e120A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombined charging-current setting\u003c\/td\u003e\n\u003ctd\u003e10–120A in 10A increments. \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser-defined bulk and float adjustment\u003c\/td\u003e\n\u003ctd\u003e48.0–64.0V in 0.1V increments. \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser-defined low-voltage cut-off adjustment\u003c\/td\u003e\n\u003ctd\u003e40.0–54.0V in 0.1V increments.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery equalisation\u003c\/td\u003e\n\u003ctd\u003eDisable for this LiFePO4 system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f2f3f5; text-align: left;\"\u003eInverter: solar input\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolar charger type\u003c\/td\u003e\n\u003ctd\u003eMPPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum PV array power\u003c\/td\u003e\n\u003ctd\u003e6,000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT operating-voltage range\u003c\/td\u003e\n\u003ctd\u003e120–430V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum PV array open-circuit voltage\u003c\/td\u003e\n\u003ctd\u003e500V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum solar input current\u003c\/td\u003e\n\u003ctd\u003e27A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolar panels\u003c\/td\u003e\n\u003ctd\u003eNot assumed included; specify a compatible array separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f2f3f5; text-align: left;\"\u003eInverter: monitoring, physical and environmental data\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl module\u003c\/td\u003e\n\u003ctd\u003eRemovable LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in wireless monitoring\u003c\/td\u003e\n\u003ctd\u003eWi-Fi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring application\u003c\/td\u003e\n\u003ctd\u003eWatchPower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication interfaces listed\u003c\/td\u003e\n\u003ctd\u003eRS232, USB, dry contact, Wi-Fi, RS485 and CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery communications qualification\u003c\/td\u003e\n\u003ctd\u003eRS485\/CAN interfaces do not establish compatibility with Fogstar Drift. No direct communications integration is claimed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions, D × W × H\u003c\/td\u003e\n\u003ctd\u003e135.5 × 300 × 500mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e15kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e−15°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e5–95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f2f3f5; text-align: left;\"\u003eFogstar Drift 300Ah: per-battery specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell type\u003c\/td\u003e\n\u003ctd\u003eGrade A EVE LF304K prismatic cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal cell configuration\u003c\/td\u003e\n\u003ctd\u003e4S1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e300Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal voltage\u003c\/td\u003e\n\u003ctd\u003e12.8V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated energy\u003c\/td\u003e\n\u003ctd\u003e3,840Wh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePublished cycle life\u003c\/td\u003e\n\u003ctd\u003e4,500 cycles at 80% depth of discharge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum continuous discharge\u003c\/td\u003e\n\u003ctd\u003e250A \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum charging current\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge cut-off voltage\u003c\/td\u003e\n\u003ctd\u003e10V per battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended charging voltage\u003c\/td\u003e\n\u003ctd\u003e14.4V per battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFour-battery charging-voltage equivalent — calculated\u003c\/td\u003e\n\u003ctd\u003e57.6V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge-temperature range\u003c\/td\u003e\n\u003ctd\u003e−20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging-temperature range in specification sheet\u003c\/td\u003e\n\u003ctd\u003e−20°C to +60°C with heater enabled. \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage conditions\u003c\/td\u003e\n\u003ctd\u003e10°C to 35°C at approximately 50% state of charge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated heating\u003c\/td\u003e\n\u003ctd\u003eBuilt-in heater; the specification sheet states heating to 5°C to enable low-temperature charging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery monitoring\u003c\/td\u003e\n\u003ctd\u003eBluetooth through the Fogstar Drift application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBMS protections listed\u003c\/td\u003e\n\u003ctd\u003eTemperature, overcurrent and overdischarge protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase material\u003c\/td\u003e\n\u003ctd\u003eABS plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions, L × W × H\u003c\/td\u003e\n\u003ctd\u003e380 × 190 × 245mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e26kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal specification\u003c\/td\u003e\n\u003ctd\u003eM8, 1.25mm pitch, 12mm; bolts supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformity designations listed in battery sheet\u003c\/td\u003e\n\u003ctd\u003eUN38.3, RoHS, CE and UL. \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f2f3f5; text-align: left;\"\u003eSystem integration requirements\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer series allowance\u003c\/td\u003e\n\u003ctd\u003eFogstar permits up to 4 of these Drift batteries in series.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInitial preparation\u003c\/td\u003e\n\u003ctd\u003eFollow Fogstar’s charging and balancing procedure before series connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eDocuments available for download\u003c\/h2\u003e\n\u003cul style=\"padding-left: 24px;\"\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/IC2-ZT5000-48___IC2-ZT6000-48_datasheet_8c9f9359-6498-481f-b4e5-439ab025e396.pdf?v=1792587264\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" target=\"_blank\"\u003eICONICA IC2-ZT5000-48 \/ IC2-ZT6000-48 datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/IC2-ZT5000-48___IC2-ZT6000-48_datasheet_8c9f9359-6498-481f-b4e5-439ab025e396.pdf?v=1792587264\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" target=\"_blank\"\u003eICONICA IC2-ZT installation and user manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Fogstar-Drift-300Ah-Specification-Sheet.pdf?v=1792587564\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" target=\"_blank\"\u003eFogstar Drift 300Ah 250A battery specification sheet\u003c\/a\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Fogstar-Drift-300Ah-Specification-Sheet.pdf?v=1792587564\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/2024_FogstarDriftManual_V3.pdf?v=1792587661\" rel=\"noopener\" target=\"_blank\"\u003eFogstar Drift battery user manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- Before publication: confirm the supplied battery revision and capacity, manufacturer approval of the complete inverter\/battery pairing, permitted series-bank charge settings, and the final accessory bundle. Replace document links with Energian-hosted copies where available. --\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eShipping\u003c\/h2\u003e\n\u003cp\u003eShipping is available to the UK, Ireland, Africa, the Caribbean and worldwide. If a shipping rate is not shown at checkout, contact us on \u003ca href=\"tel:+442080640335\"\u003e+44 20 8064 0335\u003c\/a\u003e or \u003ca href=\"mailto:info@energian.co.uk\"\u003einfo@energian.co.uk\u003c\/a\u003e for a quote.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eUK expert support\u003c\/h2\u003e\n\u003cp\u003eEnergian’s UK team can help assess essential loads, backup capacity, battery compatibility, solar design and installation requirements. Contact us by phone, email or live chat with questions or support requests, or arrange an in-person consultation at our office.\u003c\/p\u003e\n\u003c!-- Shopify SEO title: Zero Transfer Time UPS 6kW | ICONICA \u0026 Fogstar | Energian --\u003e \u003c!-- Shopify meta description: Zero transfer time UPS with ICONICA 6kW inverter-charger and four Fogstar Drift lithium batteries. 15.36kWh nominal storage. UK expert support. --\u003e \u003c!-- Suggested alt text for an actual system image: Zero transfer time UPS with ICONICA IC2-ZT6000-48 inverter-charger and four Fogstar Drift 300Ah LiFePO4 batteries. --\u003e\n\u003c\/div\u003e","brand":"Energian","offers":[{"title":"Default Title","offer_id":58277615665534,"sku":"UPS-6KW-15KWH","price":3964.69,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/ICONICA-6kw.png?v=1792588579","url":"https:\/\/www.energian.co.uk\/products\/zero-transfer-time-ups-iconica-6kw-48v-inverter-charger-and-4x-fogstar-3-84kwh-12v-lifepo4-batteries","provider":"Energian","version":"1.0","type":"link"}