{"product_id":"victron-lynx-shunt-ve-can-1000a-battery-monitor-m10","title":"Victron Lynx Shunt VE.Can 1000A Battery Monitor (M10)","description":"\u003cdiv style=\"font-size: 18px; line-height: 1.6; color: #222;\"\u003e\n\u003ch1 style=\"font-size: 32px; line-height: 1.25; text-align: center;\"\u003e\u003cstrong\u003eVictron Lynx Shunt VE.Can 1000A Battery Monitor (M10)\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eCombines a 1000A battery shunt, positive and negative DC busbars, and a location for the main system fuse in one Lynx module. \u003c\/li\u003e\n\u003cli\u003eShows battery state of charge, current, power, time remaining, temperature and alarm status through a compatible Victron GX device.\u003c\/li\u003e\n\u003cli\u003eM10 busbars for integration into modular Victron Lynx DC distribution systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eVictron Lynx Shunt VE.Can battery monitoring and DC distribution\u003c\/h2\u003e\n\u003cp\u003eThe Victron Lynx Shunt VE.Can is a 1000A DC busbar module with an integrated battery monitor and holder for the main system fuse. It is designed for larger 12V, 24V and 48V Victron installations where a central, structured approach to DC distribution, fusing and battery monitoring is required.\u003c\/p\u003e\n\u003cp\u003eConnect it to a compatible GX device, such as Cerbo GX, by VE.Can to view system data locally and remotely through the Victron VRM portal. The Lynx Shunt VE.Can is not a BMS: it monitors the battery bank and its main fuse, while the connected GX device provides configuration and data display.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1000A continuous DC rating:\u003c\/strong\u003e Suitable for high-current inverter, charger and battery-bank systems within its 12V, 24V or 48V operating range. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated battery monitoring: \u003c\/strong\u003eMeasures battery voltage, current, power, state of charge, amp-hours consumed and estimated time remaining.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain-fuse provision: \u003c\/strong\u003eIncludes a position for the system main fuse; the fuse is purchased separately and must be selected for the installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGX and VRM integration: \u003c\/strong\u003eVE.Can communication sends operational data, alarms and history to a connected GX device and, where configured, the VRM portal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable alarm relay: \u003c\/strong\u003eCan respond to battery state of charge, voltage, temperature or a blown main fuse through GX-device configuration.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eWhere to use\u003c\/h2\u003e\n\u003cp\u003eUse the Victron Lynx Shunt VE.Can in high-current solar, off-grid, marine, mobile, backup-power and commercial DC systems built around the Victron Lynx Distribution System. Typical configurations combine it with Lynx Power In, Lynx Distributor and a Cerbo GX or other compatible GX device.\u003c\/p\u003e\n\u003cp\u003eInstall the battery bank on the Lynx system’s battery side and connect all DC loads and charging sources on the system side so the shunt can calculate battery state of charge correctly. This is a specialist DC-distribution product; use a qualified installer or one of Energian’s trusted partners to design fusing, cable sizes, busbar connections and commissioning.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eTechnical specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 17px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 52.9337%;\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 47.0223%;\"\u003eVictron Lynx Shunt VE.Can\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 52.9337%;\"\u003e\u003cstrong\u003eVersions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 47.0223%;\"\u003eM10 busbar versions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 52.9337%;\"\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 47.0223%;\"\u003eDC busbars with integrated battery monitor and main-fuse holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 52.9337%;\"\u003e\u003cstrong\u003eSupply voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 47.0223%;\"\u003e9–70V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 52.9337%;\"\u003e\u003cstrong\u003eSupported system voltages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 47.0223%;\"\u003e12V, 24V or 48V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 52.9337%;\"\u003e\u003cstrong\u003eReverse-polarity protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 47.0223%;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 52.9337%;\"\u003e\u003cstrong\u003eContinuous current rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 47.0223%;\"\u003e1000A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 52.9337%;\"\u003e\u003cstrong\u003eEquivalent nominal power at 1000A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 47.0223%;\"\u003e12kW at 12V; 24kW at 24V; 48kW at 48V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 52.9337%;\"\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 47.0223%;\"\u003e60mA at 12V; 33mA at 24V; 20mA at 48V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 52.9337%;\"\u003e\u003cstrong\u003ePotential-free alarm contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 47.0223%;\"\u003e3A at 30V DC or 250V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 52.9337%;\"\u003e\u003cstrong\u003eBattery-monitor information\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 47.0223%;\"\u003eBattery voltage, current, power, state of charge, consumed amp-hours, time remaining, temperature, alarms and history\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 52.9337%;\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 47.0223%;\"\u003eVE.Can, RJ45; two VE.Can RJ45 terminators supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 52.9337%;\"\u003e\u003cstrong\u003eGX-device requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 47.0223%;\"\u003eCompatible GX device required for monitoring, setup and relay configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 52.9337%;\"\u003e\u003cstrong\u003eNMEA 2000 support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 47.0223%;\"\u003eSupported through VE.Can with a VE.Can to NMEA 2000 micro-C male cable, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 52.9337%;\"\u003e\u003cstrong\u003eTemperature sensor connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 47.0223%;\"\u003eScrew terminal; temperature sensor included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 52.9337%;\"\u003e\u003cstrong\u003eRelay connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 47.0223%;\"\u003eScrew terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 52.9337%;\"\u003e\u003cstrong\u003eFuse provision, M8 version\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 47.0223%;\"\u003eDesigned for a CNN fuse; fuse not included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 52.9337%;\"\u003e\u003cstrong\u003eFuse provision, M10 version\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 47.0223%;\"\u003eAccepts CNN, ANL or Mega fuses; fuse not included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 52.9337%;\"\u003e\u003cstrong\u003eM10 fuse-dummy busbar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 47.0223%;\"\u003eIncluded; allows the main fuse to be located outside the unit when required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 52.9337%;\"\u003e\u003cstrong\u003eBusbar material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 47.0223%;\"\u003eTinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 52.9337%;\"\u003e\u003cstrong\u003eBusbar dimensions, H × W\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 47.0223%;\"\u003e8 × 30mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 52.9337%;\"\u003e\u003cstrong\u003eEnclosure material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 47.0223%;\"\u003eABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 52.9337%;\"\u003e\u003cstrong\u003eEnclosure dimensions, H × W × D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 47.0223%;\"\u003e190 × 180 × 80mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 52.9337%;\"\u003e\u003cstrong\u003eUnit weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 47.0223%;\"\u003e1.4kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 52.9337%;\"\u003e\u003cstrong\u003eOperating temperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 47.0223%;\"\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 52.9337%;\"\u003e\u003cstrong\u003eStorage temperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 47.0223%;\"\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 52.9337%;\"\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 47.0223%;\"\u003eMaximum 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 52.9337%;\"\u003e\u003cstrong\u003eProtection class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid rgb(221, 221, 221); width: 47.0223%;\"\u003eIP22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eDocuments available for download\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Datasheet-Lynx-Shunt-VE.Can-EN.pdf?v=1786349323\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" target=\"_blank\"\u003eVictron Lynx Shunt VE.Can Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Victron-Energy-Lynx-Shunt-VE.Can-Manual.pdf?v=1786349417\" style=\"color: rgb(43, 0, 255);\" target=\"_blank\"\u003eVictron Lynx Shunt VE.Can M10 Installation and User Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eShipping\u003c\/h2\u003e\n\u003cp\u003eAvailable for shipping to the UK, Ireland, Africa, the Caribbean and worldwide. If the shipping rate is not shown at checkout, contact us on \u003ca href=\"tel:+442080640335\"\u003e+44 2080640335\u003c\/a\u003e or \u003ca href=\"mailto:info@energian.co.uk\"\u003einfo@energian.co.uk\u003c\/a\u003e for a quote.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eUK expert support\u003c\/h2\u003e\n\u003cp\u003eUK expert support is available for Victron Lynx system design, battery monitoring, fuse selection and DC distribution. Contact us with questions or support requests by phone, email or live chat, or visit our office for an in-person consultation.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":57824613007742,"sku":"LYN040102110","price":290.34,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Victron-Energy-Lynx-Shunt-VE-Can-M10.png?v=1786349484","url":"https:\/\/www.energian.co.uk\/products\/victron-lynx-shunt-ve-can-1000a-battery-monitor-m10","provider":"Energian","version":"1.0","type":"link"}