{"product_id":"victron-8kva-48v-off-grid-energy-system-with-24-0kwh-lifepo-battery-and-15kva-20kva-generator-no-solar-required","title":"Victron 8kVA 48V Off-Grid Energy System with 24.0kWh LiFePO₄ Battery and 15kVA\/20kVA Generator - No Solar Required","description":"\u003c!-- Shopify SEO title: Victron 8kVA Off-Grid Energy System | 24kWh Battery --\u003e\u003c!-- Suggested product image alt: Victron 8kVA off-grid energy system with five Pylontech US5000 batteries and selected diesel generator --\u003e\n\u003cstyle\u003e\n.energian-pdp h1{font-size:30px;line-height:1.25;margin:0 0 20px;}\n.energian-pdp h2{font-size:25px;line-height:1.3;margin:28px 0 14px;}\n.energian-pdp h3{font-size:21px;line-height:1.35;margin:22px 0 12px;}\n.energian-pdp p{margin:0 0 16px;}.energian-pdp li{margin-bottom:8px;}\n.energian-pdp table{width:100%;border-collapse:collapse;font-size:16px;line-height:1.5;}\n.energian-pdp th,.energian-pdp td{padding:11px 13px;border:1px solid #ddd;text-align:left;vertical-align:top;}\n.energian-pdp th{background:#f2f5f7;}.energian-pdp a{color:#176b95;text-decoration:underline;}\n.energian-pdp .notice{padding:16px;background:#f5f7f8;border-left:4px solid #176b95;}\n\u003c\/style\u003e\n\u003cdiv class=\"energian-pdp\" style=\"font-family: Helvetica,Arial,sans-serif; font-size: 18px; color: #333; line-height: 1.65; max-width: 900px; margin: 0 auto;\"\u003e\n\u003ch1 style=\"text-align: center;\"\u003e\u003cstrong\u003eVictron 8kVA 48V Off-Grid Energy System with 24.0kWh LiFePO₄ Battery and 15kVA\/20kVA Diesel Generator – No Solar Required\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eRun suitable off-grid equipment from battery power between generator charging sessions, without installing solar panels.\u003c\/li\u003e\n\u003cli\u003eSupply 230V single-phase loads through a Victron inverter rated at 8kVA \/ 6.4kW continuously at 25°C.\u003c\/li\u003e\n\u003cli\u003eStore 24.0kWh nominal energy in five Pylontech LiFePO₄ batteries, with a choice of Bimson Power 15kVA-class or Excel Power 20kVA prime-rated diesel generator.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eVictron 8kVA off-grid energy system: battery power without solar\u003c\/h2\u003e\n\u003cp\u003eThis Victron 8kVA off-grid energy system combines a MultiPlus-II 48\/8000\/110-100 inverter-charger, five 4.8kWh Pylontech US5000-series batteries and a selected diesel generator. The generator supplies accepted AC input and recharges the batteries. When it stops, suitable loads continue to run from stored energy, with Cerbo GX and GX Touch 50 providing system monitoring and control.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNo solar required: suitable where shading, limited roof space, tenancy restrictions or site layout make a solar array impractical.\u003c\/li\u003e\n\u003cli\u003eBattery operation between charging sessions: avoid running the generator continuously for smaller loads. Actual generator hours depend on consumption and charging requirements.\u003c\/li\u003e\n\u003cli\u003eManaged generator loading: PowerControl manages charging demand, while PowerAssist can supplement an accepted generator supply with battery power when correctly configured.\u003c\/li\u003e\n\u003cli\u003eModular lithium storage: five parallel-connected batteries provide 24.0kWh nominal and 22.8kWh usable DC energy at the specified 95% depth of discharge. Delivered AC energy is lower.\u003c\/li\u003e\n\u003cli\u003eLocal and remote visibility: monitor the system through GX Touch 50 and, with an internet connection, Victron’s VRM platform.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhere to use\u003c\/h2\u003e\n\u003cp\u003eConsider this system for logistics-site offices, security cabins, communications equipment, agricultural outbuildings, rural workshops and other premises without a suitable grid connection. Assess lighting, refrigeration, IT equipment and tool loads against their running demand and starting currents.\u003c\/p\u003e\n\u003cp\u003eThe inverter supplies 6.4kW continuously from the batteries at 25°C, reducing to 5.5kW at 40°C. A larger generator does not increase these battery-only ratings. The 15kW inverter peak figure is not a continuous operating rating.\u003c\/p\u003e\n\u003ch2\u003eChoose your diesel generator\u003c\/h2\u003e\n\u003ch3\u003e15kVA-class option: Bimson Power LDG15S-UK\u003c\/h3\u003e\n\u003cp\u003eThe single-phase LDG15S-UK provides 12,000W rated output and 13,000W maximum output, with electric key starting, AVR voltage regulation and a 35-litre diesel tank. Its ATS input is intended for the manufacturer’s compatible panel, supplied separately; it does not establish a direct Cerbo start connection.\u003c\/p\u003e\n\u003cp\u003eThe UK model has separate 240V and 120V outlets. The installed feed must respect the selected socket’s current rating; do not assume the generator’s full output can pass through one 32A socket.\u003c\/p\u003e\n\u003ch3\u003e20kVA option: Excel Power XL-DFAW-22S\u003c\/h3\u003e\n\u003cp\u003eThe Excel Power option is rated at 20kVA \/ 20kW prime and 22kVA \/ 22kW standby, at 230V single-phase. It has a water-cooled engine running at 1,500rpm, a DSE6120 controller and a 71.4-litre fuel tank. Standard connection is hard-wired; sockets are optional.\u003c\/p\u003e\n\u003cp\u003eThe Excel datasheet identifies this model as non-emissions-certified. Confirm its suitability for the intended duty, location and applicable emissions requirements before ordering.\u003c\/p\u003e\n\u003ch2\u003eHow the system works\u003c\/h2\u003e\n\u003cp\u003eWith the generator stopped, the inverter supplies the main AC output from the battery bank. Once an acceptable generator supply is available, the MultiPlus-II transfers to that supply and uses available capacity for charging within the configured limits.\u003c\/p\u003e\n\u003cp\u003eThe battery charger is limited to 110A. Generator capacity is shared between connected loads and charging, and the commissioned input limit must suit the connection and protection. No fixed runtime, recharge time or fuel-saving percentage is claimed.\u003c\/p\u003e\n\u003ch2\u003eProposed package contents\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Victron MultiPlus-II 48\/8000\/110-100 230V inverter-charger.\u003c\/li\u003e\n\u003cli\u003e5 × Pylontech US5000-series 4.8kWh LiFePO₄ battery modules, with compatible mounting brackets.\u003c\/li\u003e\n\u003cli\u003e1 × Victron Cerbo GX MK2, GX Touch 50 display and wall mount.\u003c\/li\u003e\n\u003cli\u003e1 × selected Bimson Power LDG15S-UK or Excel Power XL-DK-22S diesel generator.\u003c\/li\u003e\n\u003cli\u003eBattery cabling, terminations, isolation and protection components as itemised in the final quotation. Confirm site-specific AC protection, battery distribution, generator-control equipment and installation accessories before order.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation and commissioning\u003c\/h2\u003e\n\u003cp\u003eThis is a supply-only system, not a plug-in kit. A qualified installer must design and commission the generator connection, battery distribution, earthing, protective devices and load circuits. Energian can assist with installation through trusted partners.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIf the battery installing in or near a residential building, your installer must ensure compliance with \u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/knowledge.bsigroup.com\/products\/electrical-installations-protection-against-fire-of-battery-energy-storage-systems-for-use-in-dwellings-specification?version=standard\" style=\"color: rgb(43, 0, 255);\" target=\"_blank\"\u003ePAS 63100:2024\u003c\/a\u003e\u003c\/span\u003e.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAutomatic generator starting requires an approved interface and manufacturer-compatible controls. The Bimson manual restricts its ATS socket to the specified Bimson Power panel. Do not connect the Cerbo relay directly or substitute an unapproved ATS arrangement.\u003c\/p\u003e\n\u003cp\u003eInstall the inverter and batteries in suitable dry equipment accommodation. The Pylontech manual specifies no charging below 0°C and a maximum of three modules per bracket stack; five modules require separate compliant stacks or a suitable rack arrangement.\u003c\/p\u003e\n\u003cp\u003eCombustion generators must operate outdoors with safe exhaust clearances, away from doors, windows and air intakes. Fuel, engine oil, starter-battery maintenance and periodic servicing must be included in the operating plan.\u003c\/p\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003cp\u003eInverter figures follow the attached Victron 48\/8000\/110-100 datasheet. Battery figures are per US5000 module unless stated otherwise. Where the attached battery documents differ, installation-manual values are explicitly identified; confirm the supplied hardware revision before commissioning.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSystem configuration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem type\u003c\/td\u003e\n\u003ctd\u003eSingle-phase, generator-charged off-grid battery system.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter-charger\u003c\/td\u003e\n\u003ctd\u003eVictron MultiPlus-II 48\/8000\/110-100, 230V.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery bank\u003c\/td\u003e\n\u003ctd\u003e5 × Pylontech US5000-series modules connected in parallel.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal battery voltage\u003c\/td\u003e\n\u003ctd\u003e48V DC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal bank energy\u003c\/td\u003e\n\u003ctd\u003e24.0kWh, calculated as 5 × 4.8kWh.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eVictron Cerbo GX MK2 and GX Touch 50.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15kVA-class generator option\u003c\/td\u003e\n\u003ctd\u003eBimson Power LDG15S-UK, 230V single-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20kVA generator option\u003c\/td\u003e\n\u003ctd\u003eExcel Power XL-DK-22S, 230V single-phase.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eVictron: inverter output\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous apparent output at 25°C\u003c\/td\u003e\n\u003ctd\u003e8,000VA.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous active output at 25°C\u003c\/td\u003e\n\u003ctd\u003e6,400W.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous active output at 40°C\u003c\/td\u003e\n\u003ctd\u003e5,500W.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous active output at 65°C\u003c\/td\u003e\n\u003ctd\u003e4,000W.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak output\u003c\/td\u003e\n\u003ctd\u003e15,000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum apparent feed-in power\u003c\/td\u003e\n\u003ctd\u003e8,000VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e230V AC ±2%.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency\u003c\/td\u003e\n\u003ctd\u003e50Hz ±0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC input-voltage range\u003c\/td\u003e\n\u003ctd\u003e38–66V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum efficiency\u003c\/td\u003e\n\u003ctd\u003e95%.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero-load consumption\u003c\/td\u003e\n\u003ctd\u003e29W.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero-load consumption in AES mode\u003c\/td\u003e\n\u003ctd\u003e19W.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero-load consumption in Search mode\u003c\/td\u003e\n\u003ctd\u003e3W.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer to inverter operation\u003c\/td\u003e\n\u003ctd\u003eLess than 20ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eVictron: AC input and battery charger\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum AC input current\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer-switch rating\u003c\/td\u003e\n\u003ctd\u003e100A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC input-voltage range\u003c\/td\u003e\n\u003ctd\u003e187–265V AC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC input-frequency range\u003c\/td\u003e\n\u003ctd\u003e45–65Hz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum battery charging current\u003c\/td\u003e\n\u003ctd\u003e110A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerControl\u003c\/td\u003e\n\u003ctd\u003eManages battery-charging demand within the configured AC input-current limit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerAssist\u003c\/td\u003e\n\u003ctd\u003eAllows battery power to supplement an accepted AC input when enabled and correctly configured.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain AC output\u003c\/td\u003e\n\u003ctd\u003eInverter-backed output for suitable loads.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary AC output\u003c\/td\u003e\n\u003ctd\u003eAvailable only when accepted AC input power is present.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eVictron: controls, protection and enclosure\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVE.Bus\u003c\/td\u003e\n\u003ctd\u003eConfiguration, monitoring and system integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral-purpose communication ports\u003c\/td\u003e\n\u003ctd\u003e2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote on\/off\u003c\/td\u003e\n\u003ctd\u003eSupported.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgrammable relay\u003c\/td\u003e\n\u003ctd\u003eGeneral alarm, DC undervoltage or generator start\/stop signalling.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter relay AC contact rating\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e230V AC \/ 4A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter relay DC contact rating\u003c\/td\u003e\n\u003ctd\u003e4A up to 35V DC; 1A up to 60V DC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-site configuration\u003c\/td\u003e\n\u003ctd\u003eVEConfigure with a suitable computer and MK3-USB interface.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote monitoring\u003c\/td\u003e\n\u003ctd\u003eVictron VRM through an internet-connected GX device.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eFan-assisted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating-temperature range\u003c\/td\u003e\n\u003ctd\u003e−40°C to +65°C; output derating applies.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum humidity\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure material and colour\u003c\/td\u003e\n\u003ctd\u003eSteel, blue RAL 5012.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress protection\u003c\/td\u003e\n\u003ctd\u003eIP22.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery connections\u003c\/td\u003e\n\u003ctd\u003eFour M8 bolts: two positive and two negative connections.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC connections\u003c\/td\u003e\n\u003ctd\u003eM6 bolts.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions, H × W × D\u003c\/td\u003e\n\u003ctd\u003e642 × 363 × 206mm.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e42kg.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection functions\u003c\/td\u003e\n\u003ctd\u003eOutput short circuit; overload; high\/low battery voltage; overtemperature; external 230V on inverter output; excessive DC input ripple.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety references in supplied datasheet\u003c\/td\u003e\n\u003ctd\u003eEN-IEC 60335-1; EN-IEC 60335-2-29; EN-IEC 62109-1; EN-IEC 62109-2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmission and immunity references\u003c\/td\u003e\n\u003ctd\u003eEN 55014-1; EN 55014-2; EN-IEC 61000-3-2; EN-IEC 61000-3-3; IEC 61000-6-1; IEC 61000-6-2; IEC 61000-6-3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003ePylontech US5000: battery performance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemistry\u003c\/td\u003e\n\u003ctd\u003eLithium iron phosphate, LiFePO₄ \/ LFP.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal module voltage\u003c\/td\u003e\n\u003ctd\u003e48V DC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal module energy\u003c\/td\u003e\n\u003ctd\u003e4,800Wh \/ 4.8kWh.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsable module energy\u003c\/td\u003e\n\u003ctd\u003e4,560Wh \/ 4.56kWh.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth of discharge\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharge-voltage range\u003c\/td\u003e\n\u003ctd\u003e52.5–53.5V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum continuous charge\/discharge current\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100A per module\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak charge\/discharge current, first band\u003c\/td\u003e\n\u003ctd\u003e101–120A per module for 15 minutes.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak charge\/discharge current, second band\u003c\/td\u003e\n\u003ctd\u003e121–200A per module for 15 seconds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eCAN and RS485.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003ePylontech US5000: construction and operating conditions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule dimensions, W × D × H\u003c\/td\u003e\n\u003ctd\u003e442 × 420 × 161mm.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress protection\u003c\/td\u003e\n\u003ctd\u003eIP20.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eNatural cooling.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging temperature, attached installation manual\u003c\/td\u003e\n\u003ctd\u003e0°C to +50°C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarging temperature, attached installation manual\u003c\/td\u003e\n\u003ctd\u003e−10°C to +50°C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation ambient, attached manual\u003c\/td\u003e\n\u003ctd\u003e0°C to +50°C; optimal battery temperature stated as 10°C to 40°C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5–95% RH, non-condensing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation location\u003c\/td\u003e\n\u003ctd\u003eIndoors, dry and protected from water, direct sunlight and unsuitable temperatures.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket-supported stacking limit\u003c\/td\u003e\n\u003ctd\u003eMaximum three modules per stack in the attached installation manual.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal battery cable kit\u003c\/td\u003e\n\u003ctd\u003eSeparate from the module carton. The attached manual rates each specified external cable pair at 100A continuous; sufficient approved connections and protection are required.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecified external cable-kit length\u003c\/td\u003e\n\u003ctd\u003eLess than 3m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign life\u003c\/td\u003e\n\u003ctd\u003eMore than 15 years at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCycle life\u003c\/td\u003e\n\u003ctd\u003eMore than 6,000 cycles at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReferences listed in battery manual\u003c\/td\u003e\n\u003ctd\u003eIEC62619; IEC63056; UL1973; UL9540A; IEC61000-6-2; IEC61000-6-3; UN38.3. \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003e15kVA-class option: Bimson Power LDG15S-UK\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel and phase\u003c\/td\u003e\n\u003ctd\u003eLDG15S-UK, single-phase; do not substitute the LDG15S3 three-phase model.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarketed generator class\u003c\/td\u003e\n\u003ctd\u003e15kVA.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated active output\u003c\/td\u003e\n\u003ctd\u003e12,000W.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum active output\u003c\/td\u003e\n\u003ctd\u003e13,000W.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50Hz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUK outlets, attached brochure\u003c\/td\u003e\n\u003ctd\u003e1 × 240V 16A; 1 × 240V 32A; 1 × 120V 16A; 1 × 120V 32A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection to this system\u003c\/td\u003e\n\u003ctd\u003eUse the approved 230\/240V supply arrangement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage regulation\u003c\/td\u003e\n\u003ctd\u003eAutomatic Voltage Regulator, AVR.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStart system\u003c\/td\u003e\n\u003ctd\u003eElectric key start.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eATS provision\u003c\/td\u003e\n\u003ctd\u003eATS input socket. The manual specifies Bimson Power panel 190102000010; panel supplied separately.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCerbo automatic-start integration\u003c\/td\u003e\n\u003ctd\u003eNot established by the ATS socket. Requires manufacturer-approved integration; do not connect an unapproved ATS or direct relay interface.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEngine model, attached manual\u003c\/td\u003e\n\u003ctd\u003eLA292FA-C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEngine type\u003c\/td\u003e\n\u003ctd\u003eFour-stroke, twin-cylinder, air-cooled diesel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplacement\u003c\/td\u003e\n\u003ctd\u003e1,064cc.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEngine power, attached brochure\u003c\/td\u003e\n\u003ctd\u003e18.7HP at 3,000rpm.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBore and stroke, attached manual\u003c\/td\u003e\n\u003ctd\u003e92mm bore; 80mm stroke.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEngine speed\u003c\/td\u003e\n\u003ctd\u003e3,000rpm.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eDiesel.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel-tank capacity\u003c\/td\u003e\n\u003ctd\u003e35 litres.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEngine-oil capacity\u003c\/td\u003e\n\u003ctd\u003e3 litres.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended oil, attached manual\u003c\/td\u003e\n\u003ctd\u003e10W-30 non-synthetic or part-synthetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise level\u003c\/td\u003e\n\u003ctd\u003e75dB(A) at 7m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrumentation\u003c\/td\u003e\n\u003ctd\u003e3-in-1 Intelli Volt Meter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow-oil protection\u003c\/td\u003e\n\u003ctd\u003eLow-oil shutdown sensor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStarter-battery system, attached manual\u003c\/td\u003e\n\u003ctd\u003e12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCold-start provision\u003c\/td\u003e\n\u003ctd\u003ePreheater function described in the manual for temperatures below 0°C; operating limits and starting procedure still apply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoutine servicing, attached manual\u003c\/td\u003e\n\u003ctd\u003ePeriodic servicing at 100 hours or three months, as applicable to each maintenance item\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater exposure\u003c\/td\u003e\n\u003ctd\u003eThe manual prohibits operation exposed to rain, snow or water sprays; provide a manufacturer-approved operating location.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification marks, attached brochure\u003c\/td\u003e\n\u003ctd\u003eUKCA and CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommercial\/industrial warranty, attached manual\u003c\/td\u003e\n\u003ctd\u003eOne year or 500 operating hours, whichever occurs first\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDomestic warranty, attached manual\u003c\/td\u003e\n\u003ctd\u003eUp to two years or 1,000 operating hours, whichever occurs first\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003e20kVA option: Excel Power XL-DK-22S\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003e230V, single-phase, 50Hz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrime electrical rating\u003c\/td\u003e\n\u003ctd\u003e20kVA \/ 20kW.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandby electrical rating\u003c\/td\u003e\n\u003ctd\u003e22kVA \/ 22kW.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrime-duty definition\u003c\/td\u003e\n\u003ctd\u003eVariable load averaging 70%, in lieu of commercially purchased power; manufacturer permits 10% overload for one hour in a 12-hour operating period.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandby-duty definition\u003c\/td\u003e\n\u003ctd\u003eVariable-load operation during utility power failure; no overload permitted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEngine manufacturer\u003c\/td\u003e\n\u003ctd\u003eFAWE.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEngine model\u003c\/td\u003e\n\u003ctd\u003e4DW92-35D.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEngine configuration\u003c\/td\u003e\n\u003ctd\u003eFour cylinders, in-line, four-stroke, naturally aspirated.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGovernor\u003c\/td\u003e\n\u003ctd\u003eMechanical.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBore × stroke\u003c\/td\u003e\n\u003ctd\u003e90 × 100mm.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplacement\u003c\/td\u003e\n\u003ctd\u003e2.54 litres.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompression ratio\u003c\/td\u003e\n\u003ctd\u003e17:1.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eWater-cooled with engine-driven fan.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEngine speed\u003c\/td\u003e\n\u003ctd\u003e1,500rpm.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross engine power\u003c\/td\u003e\n\u003ctd\u003e26kW; not the generator’s electrical-output rating.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eDiesel.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel consumption at 100% load\u003c\/td\u003e\n\u003ctd\u003e5.48 litres\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel-tank capacity\u003c\/td\u003e\n\u003ctd\u003e71.4 litres.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternator make and model\u003c\/td\u003e\n\u003ctd\u003eDepco DPC184G.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternator bearing arrangement\u003c\/td\u003e\n\u003ctd\u003eSingle bearing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternator insulation class\u003c\/td\u003e\n\u003ctd\u003eClass H.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternator ingress protection\u003c\/td\u003e\n\u003ctd\u003eIP23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcitation\u003c\/td\u003e\n\u003ctd\u003eShunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage regulation\u003c\/td\u003e\n\u003ctd\u003eAVR, ±1%.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController\u003c\/td\u003e\n\u003ctd\u003eDeep Sea Electronics DSE6120.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard electrical connection\u003c\/td\u003e\n\u003ctd\u003eHard-wired; optional sockets available.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput circuit breaker\u003c\/td\u003e\n\u003ctd\u003eDelixi fixed-type, three-pole MCCB, as specified in the datasheet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExhaust\u003c\/td\u003e\n\u003ctd\u003eResidential-grade silencer within the canopy.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eEngine and alternator on anti-vibration mounts.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoupling\u003c\/td\u003e\n\u003ctd\u003eClose-coupled with SAE semi-flexible flange.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise level\u003c\/td\u003e\n\u003ctd\u003e72dB(A) at 7m in free-field conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions, L × W × H\u003c\/td\u003e\n\u003ctd\u003e1,900 × 780 × 1,000mm.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator weight\u003c\/td\u003e\n\u003ctd\u003e673kg.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRating reference conditions\u003c\/td\u003e\n\u003ctd\u003e27°C inlet air, 100kPa barometric pressure and 30% relative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmissions classification\u003c\/td\u003e\n\u003ctd\u003eNon-emissions-certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator warranty\u003c\/td\u003e\n\u003ctd\u003e12 months or 1,000 operating hours, whichever occurs first, subject to applicable terms.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eFinal system integration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery charging limit\u003c\/td\u003e\n\u003ctd\u003eUp to 110A through the MultiPlus-II, further limited by battery BMS, generator connection and commissioned settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic generator control\u003c\/td\u003e\n\u003ctd\u003eProject-specific, requiring manufacturer-approved hardware, control logic and commissioning. ATS-ready does not mean Cerbo-compatible.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection and isolation\u003c\/td\u003e\n\u003ctd\u003eFinal battery branches, fuse ratings, disconnector arrangement, cable sizes and AC protection require design verification.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery-powered runtime\u003c\/td\u003e\n\u003ctd\u003eDepends on actual consumption, usable battery energy, inverter losses, temperature and operating reserves.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecharge time\u003c\/td\u003e\n\u003ctd\u003eDepends on starting state of charge, BMS limits, connected loads and available generator charging capacity.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem warranty\u003c\/td\u003e\n\u003ctd\u003eIndividual component terms apply; no combined warranty duration is inferred.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003eDocuments available for download\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/victron-multiplus-ii-48300035-32-230v_5ad30ddd-2349-448f-b2eb-fd502d334743.webp?v=1793698930\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" target=\"_blank\"\u003eVictron MultiPlus-II datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/User_Manual_Victron_MultiPlus-II_12-3000-120-32_a6181e20-7bd3-46bd-a1a7-627c7397cb08.pdf?v=1794128672\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" target=\"_blank\"\u003eVictron MultiPlus-II installation and user manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/US5000_spec_f6f411ae-d86d-4378-9896-552e2330e481.pdf?v=1794128913\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" target=\"_blank\"\u003ePylontech US5000 manufacturer datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/US5000-Installation_manual.pdf?v=1794129001\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" target=\"_blank\"\u003ePylontech US5000 installation manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/BP_LDG15S_Brochure.pdf.pdf?v=1794129135\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" target=\"_blank\"\u003eBimson Power LDG15S specifications brochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/XL-DFAW-22S-20kVA-1-Phase-Datasheet-1.pdf?v=1794129241\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" target=\"_blank\"\u003eExcel Power XL-DFAW-22S generator datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAsk Energian for the operating manual and control-interface documentation applicable to the selected Excel generator. Manufacturer documents may cover different revisions; the supplied equipment’s nameplate and applicable instructions must be checked before installation.\u003c\/p\u003e\n\u003ch2\u003eShipping\u003c\/h2\u003e\n\u003cp\u003eShipping is available to the UK, Ireland, Africa, the Caribbean and worldwide, subject to destination and transport requirements. If a shipping rate is not shown at checkout, call \u003ca href=\"tel:+442080640335\"\u003e+44 20 8064 0335\u003c\/a\u003e or email \u003ca href=\"mailto:info@energian.co.uk\"\u003einfo@energian.co.uk\u003c\/a\u003e for a quote.\u003c\/p\u003e\n\u003cp\u003eConfirm delivery access and unloading arrangements before dispatch. Batteries and generators require suitable handling equipment and may arrive separately.\u003c\/p\u003e\n\u003ch2\u003eUK expert support\u003c\/h2\u003e\n\u003cp\u003eContact Energian’s UK team by \u003ca href=\"tel:+442080640335\"\u003ephone\u003c\/a\u003e, \u003ca href=\"mailto:info@energian.co.uk\"\u003eemail\u003c\/a\u003e or live chat for questions, support requests and system-selection advice. You can also arrange an in-person consultation at our office.\u003c\/p\u003e\n\u003cp class=\"notice\"\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e This system requires professional installation and commissioning. Ask us about installation through trusted partners and request the final equipment schedule before ordering.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Victron Energy","offers":[{"title":"Victron 8kVA + Pylontech 24kWh Battery + Bimson Power 15.0kW Diesel Generatorr","offer_id":58409679651198,"sku":null,"price":12983.91,"currency_code":"GBP","in_stock":true},{"title":"Victron 8kVA + Pylontech 24kWh Battery + Excel XL-DK-22S Diesel Generator","offer_id":58409679683966,"sku":null,"price":15106.84,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/MultiPlus-II8000VA.jpg?v=1794129478","url":"https:\/\/www.energian.co.uk\/products\/victron-8kva-48v-off-grid-energy-system-with-24-0kwh-lifepo-battery-and-15kva-20kva-generator-no-solar-required","provider":"Energian","version":"1.0","type":"link"}