{"product_id":"victron-3kva-48v-off-grid-energy-system-with-10-2kwh-lifepo-battery-and-5-5-6-5kw-generator-no-solar-required","title":"Victron 3kVA 48V Off-Grid Energy System with 10.2kWh LiFePO₄ Battery and 5.5-6.5kW Generator - No Solar Required","description":"\u003cdiv style=\"font-family: Helvetica,Arial,sans-serif; color: #333; line-height: 1.65; font-size: 18px; max-width: 1000px; margin: 0 auto;\"\u003e\n\u003ch1 style=\"font-size: 32px; line-height: 1.25; text-align: center;\"\u003e\u003cstrong\u003eVictron 3kVA 48V Off-Grid Energy System with 10.2kWh LiFePO₄ Battery and 5.5–6.5kW Generator – No Solar Required\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cul style=\"font-size: 18px; padding-left: 24px;\"\u003e\n\u003cli\u003eRun suitable off-grid loads without solar panels, using battery power between generator charging sessions.\u003c\/li\u003e\n\u003cli\u003eVictron MultiPlus-II provides 230V pure sine wave power, rated at 3kVA \/ 2.4kW continuously at 25°C.\u003c\/li\u003e\n\u003cli\u003eDyness Powerbox G2 provides 10.24kWh nominal lithium storage, paired with a separately specified 5.5–6.5kW-class generator.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eOff-grid battery and generator power without solar\u003c\/h2\u003e\n\u003cp\u003eThis Victron 3kVA off-grid energy system combines a MultiPlus-II 48\/3000\/35-32 inverter-charger, a Dyness Powerbox G2 LiFePO₄ battery and a selected generator in the 5.5–6.5kW class. The generator supplies accepted AC power and recharges the battery through the inverter-charger. When it stops, suitable connected loads continue to operate from stored energy without requiring solar panels.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eKey features\u003c\/h2\u003e\n\u003cul style=\"padding-left: 24px;\"\u003e\n\u003cli\u003eNo solar required: suitable where shading, limited space, seasonal use or site restrictions make a solar array impractical.\u003c\/li\u003e\n\u003cli\u003eBattery operation between charging sessions: supply suitable loads without running the generator continuously. Actual generator hours depend on consumption and charging requirements.\u003c\/li\u003e\n\u003cli\u003eManaged generator loading: PowerControl limits AC input demand, while PowerAssist can supplement an accepted generator supply with battery power when correctly configured.\u003c\/li\u003e\n\u003cli\u003eDyness lithium storage: 10.24kWh nominal capacity, IP65 protection and CAN\/RS485 communication, with floor- or wall-mounted installation options.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eWhere to use\u003c\/h2\u003e\n\u003cp\u003eConsider this system for remote offices, cabins, rural outbuildings, seasonal accommodation, communications equipment and selected small-business loads where grid power or solar generation is unavailable or unsuitable.\u003c\/p\u003e\n\u003cp\u003eCheck daily energy demand, simultaneous loads and starting currents before specifying the package. The inverter’s continuous battery-powered output is 2.4kW at 25°C; a larger generator does not increase that battery-only rating.\u003c\/p\u003e\n\u003cp\u003eAppliances such as pumps, compressors, kettles and electric heaters can place substantial demands on a small inverter system. Energian can help assess the intended equipment and identify which loads should operate only while the generator is running.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eHow the system works\u003c\/h2\u003e\n\u003cp\u003eWith the generator stopped, the inverter converts battery DC power into 230V AC. When an acceptable generator supply is connected, the MultiPlus-II supplies the loads and uses available input capacity to charge the battery, within the commissioned limits.\u003c\/p\u003e\n\u003cp\u003eThe inverter charger is rated at 35A. A larger generator does not increase charging beyond this limit. Generator loads, charging demand and any PowerAssist contribution must be managed within the generator outlet, inverter, battery, cable and protection ratings.\u003c\/p\u003e\n\u003cp\u003eNo solar required does not mean no energy input is required: generator fuel replenishes the battery. Runtime, recharge time and fuel use depend on the load profile, generator model and operating settings; no fixed performance figures are guaranteed.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eProposed package contents\u003c\/h2\u003e\n\u003cul style=\"padding-left: 24px;\"\u003e\n\u003cli\u003e1 × \u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/www.energian.co.uk\/collections\/off-grid-inverters\/products\/victron-multiplus-ii-48-3000-35-32-3kva-2-4kw-48v-off-grid-hybrid-inverter-charger\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" target=\"_blank\"\u003eVictron MultiPlus-II 48\/3000\/35-32 230V inverter-charger\u003c\/a\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e1 × \u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/www.energian.co.uk\/collections\/solar-batteries\/products\/dyness-powerbox-g2-10-24kwh-battery-system-up-to-512kwh-in-parallel\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" target=\"_blank\"\u003eDyness Powerbox G2 51.2V 200Ah LiFePO₄ battery\u003c\/a\u003e\u003c\/span\u003e, rated at 10.24kWh nominal energy.\u003c\/li\u003e\n\u003cli\u003e1x \u003cspan\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.energian.co.uk\/products\/victron-cerbo-gx-comms-centre\" rel=\"noopener\" target=\"_blank\"\u003eVictron Cerbo GX\u003c\/a\u003e\u003c\/span\u003e and \u003cspan\u003e\u003ca href=\"https:\/\/www.energian.co.uk\/products\/victron-gx-touch-50-touchscreen-display-for-cerbo-gx\" rel=\"noopener\" target=\"_blank\"\u003eVictron GX Touch 50\u003c\/a\u003e\u003c\/span\u003e display,\u003c\/span\u003e \u003c\/li\u003e\n\u003cli\u003e1x \u003ca class=\"breadcrumbs-list__link\" href=\"https:\/\/www.energian.co.uk\/products\/diesel-generatoren-ks-9200hdes-1-3-atsr\" aria-current=\"page\"\u003eKönner \u0026amp; Söhnen KS 9200HDES-1\/3 ATSR (EURO 5) 6.0kW (230V) 7.0kW (400V) Diesel Generator\u003c\/a\u003e, or \u003c\/li\u003e\n\u003cli\u003e1x \u003ca class=\"breadcrumbs-list__link\" href=\"https:\/\/www.energian.co.uk\/products\/lpg-petrol-generator-ks-7000e-g\" aria-current=\"page\"\u003eKönner \u0026amp; Söhnen KS 7000E G 5.5kW Dual-Fuel LPG\/Petrol Generator\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e1x Complete set of cables, connectors, disconnectors, and accessories.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eInstallation and commissioning\u003c\/h2\u003e\n\u003cp\u003eThis is not a plug-in installation. A qualified electrician must design the generator connection, earthing, protective devices, battery connections and load circuits. Installation can be arranged through trusted partners.\u003c\/p\u003e\n\u003cp\u003eDyness lists Victron Energy among compatible inverter brands. Confirm the exact battery firmware, approved communication cable, GX requirements and inverter settings before commissioning. Do not assume the inverter’s default charging profile is suitable for the battery.\u003c\/p\u003e\n\u003cp\u003eAutomatic generator starting is assumed. It requires a compatible generator and an approved control interface. A combustion generator must operate outdoors in a safe location away from doors, windows and air intakes—not inside the battery or inverter enclosure.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eTechnical specifications\u003c\/h2\u003e\n\u003cp\u003eInverter specifications follow the attached Victron datasheet’s 48\/3000\/35-32 model. Battery specifications follow the attached Dyness Powerbox G2 datasheet, version 20241231-EN. Generator-specific data will be added when the model is selected.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 17px; text-align: left;\" border=\"1\" cellpadding=\"10\"\u003e\n\u003cthead style=\"background: #f2f3f5;\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width: 55%;\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f2f3f5; text-align: left;\"\u003eSystem configuration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem type\u003c\/td\u003e\n\u003ctd\u003eSingle-phase, generator-charged off-grid energy system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolar requirement\u003c\/td\u003e\n\u003ctd\u003eNo solar panels required for the proposed generator\/battery operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter-charger\u003c\/td\u003e\n\u003ctd\u003eVictron MultiPlus-II 48\/3000\/35-32, 230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery model\u003c\/td\u003e\n\u003ctd\u003eDyness Powerbox G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery chemistry\u003c\/td\u003e\n\u003ctd\u003eLiFePO₄ \/ lithium iron phosphate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal battery voltage\u003c\/td\u003e\n\u003ctd\u003e51.2V; 48V-class system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal battery capacity\u003c\/td\u003e\n\u003ctd\u003e200Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal stored energy\u003c\/td\u003e\n\u003ctd\u003e10.24kWh, described as approximately 10.2kWh in the product title\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended depth of discharge\u003c\/td\u003e\n\u003ctd\u003e90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy at 90% discharge allowance — calculated\u003c\/td\u003e\n\u003ctd\u003e9.216kWh of nominal battery energy before inverter losses and operating restrictions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator selection\u003c\/td\u003e\n\u003ctd\u003e5.5–6.5kW class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuture solar integration\u003c\/td\u003e\n\u003ctd\u003ePossible using separately specified compatible MPPT solar charge controller; the MultiPlus-II does not contain a PV MPPT controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f2f3f5; text-align: left;\"\u003eVictron inverter output\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous apparent output at 25°C\u003c\/td\u003e\n\u003ctd\u003e3,000VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous active output at 25°C\u003c\/td\u003e\n\u003ctd\u003e2,400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous active output at 40°C\u003c\/td\u003e\n\u003ctd\u003e2,200W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous active output at 65°C\u003c\/td\u003e\n\u003ctd\u003e1,700W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak inverter power\u003c\/td\u003e\n\u003ctd\u003e5,500W; system surge capability also depends on battery voltage, BMS limits, cabling and protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e230V AC ±2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency\u003c\/td\u003e\n\u003ctd\u003e50Hz ±0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput waveform\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC input-voltage range\u003c\/td\u003e\n\u003ctd\u003e38–66V DC; actual operation must remain within the connected battery’s permitted range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum inverter efficiency\u003c\/td\u003e\n\u003ctd\u003e95% for the 48V 3kVA model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero-load consumption\u003c\/td\u003e\n\u003ctd\u003e11W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero-load consumption in AES mode\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero-load consumption in Search mode\u003c\/td\u003e\n\u003ctd\u003e2W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum apparent feed-in power\u003c\/td\u003e\n\u003ctd\u003e3,000VA component rating; grid export is not part of this off-grid package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC transfer time\u003c\/td\u003e\n\u003ctd\u003eLess than 20ms, as described by Victron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f2f3f5; text-align: left;\"\u003eVictron generator input and charging\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC input-voltage range\u003c\/td\u003e\n\u003ctd\u003e187–265V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC input-frequency range\u003c\/td\u003e\n\u003ctd\u003e45–65Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum AC input current\u003c\/td\u003e\n\u003ctd\u003e32A; commission a limit appropriate to the generator, outlet, cable and protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer-switch rating\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum battery charging current\u003c\/td\u003e\n\u003ctd\u003e35A, up to 25°C ambient, subject to available AC input and battery limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery temperature sensor\u003c\/td\u003e\n\u003ctd\u003eSupported; follow the approved lithium battery\/BMS configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerControl\u003c\/td\u003e\n\u003ctd\u003eReduces charging demand to respect the configured AC input-current limit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerAssist\u003c\/td\u003e\n\u003ctd\u003eAllows battery power to supplement an accepted AC source when enabled and correctly configured\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC output 1\u003c\/td\u003e\n\u003ctd\u003eMain inverter-backed output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC output 2\u003c\/td\u003e\n\u003ctd\u003e32A auxiliary output, available only when accepted AC input is present\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgrammable relay\u003c\/td\u003e\n\u003ctd\u003eConfigurable for general alarm, DC undervoltage or generator start\/stop signalling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay AC contact rating\u003c\/td\u003e\n\u003ctd\u003e230V AC \/ 4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay DC contact rating\u003c\/td\u003e\n\u003ctd\u003e4A up to 35V DC; 1A up to 60V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f2f3f5; text-align: left;\"\u003eVictron monitoring, communication and expansion\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVE.Bus communication\u003c\/td\u003e\n\u003ctd\u003eSystem integration, remote monitoring and supported parallel\/three-phase configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral-purpose communication ports\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote on\/off\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional external AC current sensor\u003c\/td\u003e\n\u003ctd\u003e50A or 100A, as applicable; does not increase this model’s 32A AC input rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote monitoring\u003c\/td\u003e\n\u003ctd\u003eOptional Cerbo GX with internet connection to Victron VRM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVRM platform\u003c\/td\u003e\n\u003ctd\u003eFree remote monitoring platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal configuration\u003c\/td\u003e\n\u003ctd\u003eVEConfigure with suitable computer\/interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Bluetooth\u003c\/td\u003e\n\u003ctd\u003eVE.Bus Smart Dongle; not assumed included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel\/three-phase capability\u003c\/td\u003e\n\u003ctd\u003eSupported with matching compatible units and a redesigned installation; this listing includes one inverter only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f2f3f5; text-align: left;\"\u003eVictron enclosure, environment and standards\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eFan-assisted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−40°C to +65°C; output derating applies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum humidity\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure material and colour\u003c\/td\u003e\n\u003ctd\u003eSteel, blue RAL 5012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter ingress protection\u003c\/td\u003e\n\u003ctd\u003eIP22; install in a suitable protected location\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery terminals\u003c\/td\u003e\n\u003ctd\u003eM8 bolts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V AC terminals\u003c\/td\u003e\n\u003ctd\u003eScrew terminals, up to 13mm² \/ 6AWG, as stated in the supplied datasheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions, H × W × D\u003c\/td\u003e\n\u003ctd\u003e499 × 268 × 141mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter weight\u003c\/td\u003e\n\u003ctd\u003e19kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection functions\u003c\/td\u003e\n\u003ctd\u003eOutput short circuit, overload, high\/low battery voltage, overtemperature, external 230V at inverter output and excessive DC input ripple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety references\u003c\/td\u003e\n\u003ctd\u003eEN-IEC 60335-1; EN-IEC 60335-2-29; EN-IEC 62109-1; EN-IEC 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmission and immunity references\u003c\/td\u003e\n\u003ctd\u003eEN 55014-1; EN 55014-2; EN-IEC 61000-3-2; EN-IEC 61000-3-3; IEC 61000-6-1, -6-2 and -6-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPS and anti-islanding approvals\u003c\/td\u003e\n\u003ctd\u003eRefer to the applicable model-specific certificates on Victron’s website; no additional approval is inferred for this complete package.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f2f3f5; text-align: left;\"\u003eDyness Powerbox G2 electrical specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd\u003eLiFePO₄\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal battery energy\u003c\/td\u003e\n\u003ctd\u003e10.24kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal voltage\u003c\/td\u003e\n\u003ctd\u003e51.2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating-voltage range\u003c\/td\u003e\n\u003ctd\u003e44.8–57.6V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e200Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal charge\/discharge power\u003c\/td\u003e\n\u003ctd\u003e5.12kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax discharge power\u003c\/td\u003e\n\u003ctd\u003e10.24kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended charge\/discharge rate\u003c\/td\u003e\n\u003ctd\u003e0.5C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended charge\/discharge current\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended depth of discharge\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\/inverter power distinction\u003c\/td\u003e\n\u003ctd\u003eThe battery’s power ratings do not increase the inverter’s 2.4kW continuous battery-powered AC output.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eCAN \/ RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWi-Fi module\u003c\/td\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f2f3f5; text-align: left;\"\u003eDyness Powerbox G2 construction and environment\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery protection level\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions, W × D × H\u003c\/td\u003e\n\u003ctd\u003e700 × 165 × 640mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery net weight\u003c\/td\u003e\n\u003ctd\u003e96kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation options\u003c\/td\u003e\n\u003ctd\u003eWall-mounted or floor-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging-temperature range\u003c\/td\u003e\n\u003ctd\u003e0°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarging-temperature range\u003c\/td\u003e\n\u003ctd\u003e−20°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCold-weather charging\u003c\/td\u003e\n\u003ctd\u003eDo not charge below the specified minimum cell temperature. A separate approved temperature-management solution is required where necessary.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePublished safety features\u003c\/td\u003e\n\u003ctd\u003eShort-circuit lockout and surge resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery equalisation feature\u003c\/td\u003e\n\u003ctd\u003eManufacturer lists support for mixing modules at different states of charge; follow its approved expansion procedure. This is not permission to enable lead-acid equalisation charging.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion\u003c\/td\u003e\n\u003ctd\u003eUp to 50 compatible units in parallel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCycle life\u003c\/td\u003e\n\u003ctd\u003eUnlimited cycles, 10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification and safety references listed\u003c\/td\u003e\n\u003ctd\u003eUN38.3; CE-EMC; IEC62619; IEC62040; UKCA; CEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f2f3f5; text-align: left;\"\u003eGenerator selection and complete-system requirements\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator range\u003c\/td\u003e\n\u003ctd\u003e5.5–6.5kW class; one selected generator per package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequired electrical output\u003c\/td\u003e\n\u003ctd\u003eCompatible single-phase 230V AC supply with sufficient continuous output at the selected outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRating basis\u003c\/td\u003e\n\u003ctd\u003eIdentify continuous and maximum generator ratings separately before quotation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-phase availability\u003c\/td\u003e\n\u003ctd\u003eA generator’s total three-phase rating must not be treated as its available single-phase output.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable charging current\u003c\/td\u003e\n\u003ctd\u003eLimited to the inverter’s 35A charger rating, available generator power and the commissioned battery limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator fuel, tank, noise and runtime\u003c\/td\u003e\n\u003ctd\u003eTo be specified from the selected generator’s manufacturer documents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator dimensions and weight\u003c\/td\u003e\n\u003ctd\u003eTo be confirmed for the selected model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombined inverter and battery weight\u003c\/td\u003e\n\u003ctd\u003e115kg, excluding generator, cables, protection equipment and enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeather protection\u003c\/td\u003e\n\u003ctd\u003eNo single overall IP rating claimed. Each component requires a suitable installation location.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinal commissioning checks\u003c\/td\u003e\n\u003ctd\u003eBattery communication, charging limits, generator acceptance, load steps, PowerAssist operation, earthing and protective-device coordination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eDocuments available for download\u003c\/h2\u003e\n\u003cul style=\"padding-left: 24px;\"\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Victron_MultiPlus_II_Datasheet_8169f1fd-732b-4a7c-b5c8-044e7beb5e96.pdf?v=1793697283\" rel=\"noopener\" style=\"color: rgb(43, 0, 255);\" target=\"_blank\"\u003eVictron MultiPlus-II inverter-charger datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/www.victronenergy.com\/media\/pg\/MultiPlus-II_230V\/en\/index-en.html\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" target=\"_blank\"\u003eVictron MultiPlus-II installation and user manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/PowerboxG2datasheetEN2024.12.26.pdf?v=1793698687\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eDyness Powerbox G2 datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/PowerBoxG2UserManualENV1.pdf?v=1793698768\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" target=\"_blank\"\u003eDyness Powerbox G2 user manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- Before publication: select the exact generator variants, add each generator’s datasheet and user-manual links, confirm continuous output and available single-phase power, and finalise battery communication, monitoring hardware and included protection equipment. Obtain the current UK-applicable battery installation and warranty documents. --\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eShipping\u003c\/h2\u003e\n\u003cp\u003eShipping is available to the UK, Ireland, Africa, the Caribbean and worldwide, subject to destination and transport requirements. If a shipping rate is not shown at checkout, contact us on \u003ca href=\"tel:+442080640335\"\u003e+44 20 8064 0335\u003c\/a\u003e or \u003ca href=\"mailto:info@energian.co.uk\"\u003einfo@energian.co.uk\u003c\/a\u003e for a quote.\u003c\/p\u003e\n\u003cp\u003eDelivery access and unloading arrangements must be agreed before dispatch. The battery and generator require appropriate handling equipment.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eUK expert support\u003c\/h2\u003e\n\u003cp\u003eEnergian’s UK team can help assess loads, battery capacity, generator selection and installation requirements. Contact us by phone, email or live chat with questions or support requests, or arrange an in-person consultation at our office. Installation can be arranged through trusted partners.\u003c\/p\u003e\n\u003c!-- Shopify SEO title: Victron 3kVA Off-Grid Battery \u0026 Generator System | Energian --\u003e \u003c!-- Shopify meta description: Victron 3kVA 48V off-grid system with Dyness 10.24kWh LiFePO4 battery and a selected 5.5–6.5kW-class generator. No solar required. UK expert support. --\u003e \u003c!-- Suggested alt text for an actual package image: Victron 3kVA 48V off-grid energy system with Dyness Powerbox Pro 10.24kWh battery and selected 5.5–6.5kW generator. --\u003e\n\u003c\/div\u003e","brand":"Victron Energy","offers":[{"title":"Victron 3kVA + Dyness 10.2kWh Battery + Könner \u0026 Söhnen 6.0kW Diesel Generatorr","offer_id":58372867490174,"sku":null,"price":5480.98,"currency_code":"GBP","in_stock":true},{"title":"Victron 3kVA + Dyness 10.2kWh Battery + Könner \u0026 Söhnen 5.5kW Dual Fuel Generator","offer_id":58372867522942,"sku":null,"price":4629.76,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/victron-multiplus-ii-48300035-32-230v_5ad30ddd-2349-448f-b2eb-fd502d334743.webp?v=1793698930","url":"https:\/\/www.energian.co.uk\/products\/victron-3kva-48v-off-grid-energy-system-with-10-2kwh-lifepo-battery-and-5-5-6-5kw-generator-no-solar-required","provider":"Energian","version":"1.0","type":"link"}