{"product_id":"sunsynk-c-i-energy-storage-system-with-30-kw-hybrid-hv-inverter-and-61-44-kwh-battery","title":"Sunsynk C\u0026I Energy Storage System With 30 kW Hybrid HV Inverter and 61.44 kWh Battery","description":"\u003cdiv style=\"font-size: 16px; line-height: 1.6;\"\u003e\n\u003c!-- A. Product Title \/ Heading --\u003e\n\u003ch1 style=\"text-align: center;\"\u003eSunsynk C\u0026amp;I Energy Storage System with 30 kW 3‑Phase Hybrid Inverter and 61.44 kWh Battery\u003c\/h1\u003e\n\u003c!-- B. Key value proposition --\u003e\n\u003ch2\u003eKey benefits \u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated three‑phase hybrid high‑voltage inverter and rack‑mount LiFePO₄ battery stack delivering up to 30 kW and 61.44 kWh of storage for commercial and industrial sites.\u003c\/li\u003e\n\u003cli\u003eHigh‑voltage battery configuration (SUNSYNK‑GX G60) optimised for Sunsynk hybrid inverters, simplifying design for self‑consumption, peak shaving and backup power.\u003c\/li\u003e\n\u003cli\u003eRobust LiFePO₄ chemistry, IP65 wall‑mount inverter and IP20 rack‑mount cabinet, suitable for well‑ventilated plant rooms and light‑industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- C. Brief Description --\u003e\n\u003ch2\u003eSystem overview\u003c\/h2\u003e\n\u003cp\u003eThis Sunsynk C\u0026amp;I energy storage system combines a SUN‑30K‑SG01HP3‑EU‑BM3 three‑phase hybrid inverter with a SUNSYNK‑GX G60 high‑voltage battery rack (12 x 5.12 kWh modules) to provide 30 kW of AC power and 61.44 kWh of nominal DC storage. It is designed for commercial and industrial applications where you need to integrate PV, batteries and grid\/generator to reduce demand charges, improve resilience and increase renewable self‑consumption.\u003c\/p\u003e\n\u003c!-- D. Key features --\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.energian.co.uk\/collections\/hybrid-inverters\/products\/sunsynk-30kw-hv-commercial-3-phase-hybrid-inverter\" target=\"_blank\"\u003eThree‑phase hybrid inverter\u003c\/a\u003e:\u003c\/strong\u003e SUN‑30K‑SG01HP3‑EU‑BM3 with up to 39 kW PV input, dual battery inputs, generator\/AC‑couple input and full UPS functionality.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.energian.co.uk\/collections\/solar-batteries\/products\/sunsynk-61-44kwh-battery-stack-with-bms-and-cabinet\" target=\"_blank\"\u003eHigh‑voltage LiFePO₄ 61.44kWh battery stack\u003c\/a\u003e:\u003c\/strong\u003e GX G60 configuration with 12 modules in series (51.2 V, 100 Ah each), providing 61.44 kWh total DC energy and 55.29 kWh usable (90 % DOD).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible C\u0026amp;I operation:\u003c\/strong\u003e supports self‑consumption, backup power, smart load and AC‑coupled operation with three‑phase 230\/400 V output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong life and warranty:\u003c\/strong\u003e ≥6000 cycles at 70 % end‑of‑life SoH for the battery and 10‑year battery warranty, plus 5‑year inverter warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated protections:\u003c\/strong\u003e anti‑islanding, over‑current, over‑voltage, lightning and leakage monitoring in the inverter, plus HV battery control, status indication and communication.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- E. Technical specifications --\u003e\n\u003ch2\u003eTechnical specifications - hybrid inverter\u003c\/h2\u003e\n\u003ch3\u003eBattery input data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery type:\u003c\/strong\u003e Li‑ion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. charging current:\u003c\/strong\u003e 50 A + 50 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. discharging current:\u003c\/strong\u003e 50 A + 50 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of battery inputs:\u003c\/strong\u003e 2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharging strategy:\u003c\/strong\u003e self‑adaptation to BMS.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePV string input data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. DC input power:\u003c\/strong\u003e 39 000 W.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. DC input voltage:\u003c\/strong\u003e 1000 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart‑up voltage:\u003c\/strong\u003e 180 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMPPT voltage range:\u003c\/strong\u003e 150–850 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull‑load DC voltage range:\u003c\/strong\u003e 360–850 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated DC input voltage:\u003c\/strong\u003e 600 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePV input current:\u003c\/strong\u003e 36 + 36 + 36 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. PV Isc:\u003c\/strong\u003e 55 + 55 + 55 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo. of MPPT trackers:\u003c\/strong\u003e 3.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo. of strings per MPPT:\u003c\/strong\u003e 2 + 2 + 2.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAC output data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated AC output and UPS power:\u003c\/strong\u003e 30 000 W.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. AC output power:\u003c\/strong\u003e 33 000 W.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak power (off‑grid):\u003c\/strong\u003e 1.5 × rated power for 10 s.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC output rated current:\u003c\/strong\u003e 45.5 \/ 43.5 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. AC current:\u003c\/strong\u003e 60 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. continuous AC pass‑through:\u003c\/strong\u003e 150 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenerator input \/ smart load \/ AC‑couple current:\u003c\/strong\u003e 45.5 \/ 150 \/ 45.5 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower factor:\u003c\/strong\u003e 0.8 leading to 0.8 lagging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput frequency and voltage:\u003c\/strong\u003e 50 \/ 60 Hz; 3L\/N\/PE 220\/380, 230\/400 Vac.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrid type:\u003c\/strong\u003e three phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC injection current:\u003c\/strong\u003e \u0026lt;0.5 % I\u003csub\u003en\u003c\/sub\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEfficiency\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. efficiency:\u003c\/strong\u003e 97.60 %.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEuro efficiency:\u003c\/strong\u003e 97.00 %.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMPPT efficiency:\u003c\/strong\u003e \u0026gt;99 %.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProtection functions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePV input lightning protection:\u003c\/strong\u003e integrated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnti‑islanding protection:\u003c\/strong\u003e integrated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePV string input reverse‑polarity protection:\u003c\/strong\u003e integrated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation resistor detection:\u003c\/strong\u003e integrated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidual current monitoring unit:\u003c\/strong\u003e integrated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput over‑current, short‑circuit and over‑voltage protection:\u003c\/strong\u003e integrated; output over‑voltage protection includes DC Type II \/ AC Type III surge protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery over‑current protection:\u003c\/strong\u003e fuses.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertifications and standards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrid regulations:\u003c\/strong\u003e VDE 4105, IEC 61727 \/ 62116, VDE 0126, AS 4777.2, CEI 0‑21, EN 50549‑1, G98, G99, C10‑11, UNE 217002, NBR 16149 \/ NBR 16150.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC \/ safety regulations:\u003c\/strong\u003e IEC 62109‑1 \/ ‑2, NBT 32004‑2018, EN 61000‑6‑1, EN 61000‑6‑2, EN 61000‑6‑3, EN 61000‑6‑4.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGeneral data – inverter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature range:\u003c\/strong\u003e −40 to 60 °C (derating above 45 °C).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling:\u003c\/strong\u003e intelligent air cooling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise:\u003c\/strong\u003e ≤45 dB.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication with BMS:\u003c\/strong\u003e RS485; CAN.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 75 kg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize (W × H × D):\u003c\/strong\u003e 527 × 894 × 294 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection degree:\u003c\/strong\u003e IP65.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation style:\u003c\/strong\u003e wall‑mounted.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 5 years.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications – 61.44 kWh\u003c\/h2\u003e\n\u003ch3\u003eMain parameters \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e SUNSYNK‑GX (X = 15,20,25,30,35,40,45,50,55,60); G60 used here.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery cell chemistry:\u003c\/strong\u003e Lithium Ferro Phosphate (LiFePO₄ or LFP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule energy:\u003c\/strong\u003e 5.12 kWh.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule nominal voltage:\u003c\/strong\u003e 51.2 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule capacity:\u003c\/strong\u003e 100 Ah.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery module quantity in series (G60):\u003c\/strong\u003e 12.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem nominal voltage (G60):\u003c\/strong\u003e 614.4 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem operating voltage (G60):\u003c\/strong\u003e 499.2–700 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem energy (G60):\u003c\/strong\u003e 61.44 kWh.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem usable energy¹ (G60):\u003c\/strong\u003e 55.29 kWh (DC usable energy at 90 % DOD, 0.2C charge\/discharge at 25 °C).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated DC power (G60):\u003c\/strong\u003e 61.44 (kW, matching energy figure).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCharge \/ discharge current and operating conditions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended charge\/discharge current:\u003c\/strong\u003e 50 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal charge\/discharge current:\u003c\/strong\u003e 100 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak discharge current:\u003c\/strong\u003e 125 A (2 minutes, 25 °C).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorking temperature:\u003c\/strong\u003e charge 0–55 °C; discharge −20–55 °C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus indicator:\u003c\/strong\u003e yellow – battery high‑voltage power on; red – battery system alarm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication port:\u003c\/strong\u003e CAN2.0 \/ RS485.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5–85 % RH.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e ≤2000 m.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP rating of enclosure:\u003c\/strong\u003e IP20.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation location:\u003c\/strong\u003e rack mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage temperature:\u003c\/strong\u003e 0–35 °C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended depth of discharge:\u003c\/strong\u003e 90 %.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCycle life:\u003c\/strong\u003e 25 ±2 °C, 0.5C\/0.5C, EOL 70 % ≥6000 cycles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty³:\u003c\/strong\u003e 10 years (whichever is reached first – warranty period or cycle power).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification:\u003c\/strong\u003e CE \/ IEC 62619 \/ VDE 2510‑50 \/ UL 1973 \/ UL 9540A \/ UN 38.3.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDimensions and weight (rack system)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W \/ D \/ H):\u003c\/strong\u003e 589 × 590 × 1640 mm or 589 × 590 × 2240 mm (rack variants).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproximate weight:\u003c\/strong\u003e 258 kg, 434 kg or 628 kg depending on configuration and rack height.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh‑voltage control box:\u003c\/strong\u003e 750 V \/ 100 A, quantity 1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5.12 kWh battery module:\u003c\/strong\u003e general module, quantity 1 in component list (actual system uses multiple).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e120 Ω terminal resistor:\u003c\/strong\u003e quantity 1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication cables:\u003c\/strong\u003e 110 mm for battery modules, 140 mm for HV control box, standard, quantity 12.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e220 mm positive power cord – HV control box:\u003c\/strong\u003e standard, quantity 1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e220 mm positive power cord – battery module:\u003c\/strong\u003e standard, quantity 11.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNegative power cord – HV control box:\u003c\/strong\u003e standard, quantity 1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e140 mm ground wire A:\u003c\/strong\u003e standard connecting cable A (connecting the HV control box), quantity 1; ground wire B for external rack connection not provided.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal PCS positive power cord (EPCable5.0):\u003c\/strong\u003e optional, quantity 1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal PCS negative power cord (ENCable5.0):\u003c\/strong\u003e optional, quantity 1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal 12 V power cord (EPWRCable5.0):\u003c\/strong\u003e optional, quantity 1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal device communication cable (ECOM Cable5.0):\u003c\/strong\u003e optional, quantity 1.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- F. Shipping and support --\u003e\n\u003ch2\u003eShipping and UK support\u003c\/h2\u003e\n\u003cp\u003eShipping is available to the UK, Ireland, Africa, the Caribbean and worldwide. If the shipping rate is not shown at checkout, please contact us on +44 2080 640335 or \u003ca href=\"mailto:info@energian.co.uk\"\u003einfo@energian.co.uk\u003c\/a\u003e for a quote.\u003c\/p\u003e\n\u003cp\u003eUK expert support is available – contact Energian with any questions or support requests via phone, email or live chat, or visit our office for an in‑person consultation to review your Sunsynk C\u0026amp;I storage design, including PV sizing, grid constraints, generator integration and installation requirements.\u003c\/p\u003e\n\u003c!-- Documents section --\u003e\n\u003ch2\u003eDocuments available for download\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eS\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Three-phase-hybrid-inverter-25-50kw.pdf?v=1782204462\" style=\"color: rgb(43, 0, 255);\" target=\"_blank\"\u003eunsynk Three‑Phase Hybrid Inverter 25–50 kW datasheet.\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Sunsynk_High_Voltage_Series_Datasheet_v8_English.pdf?v=1782199855\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" target=\"_blank\"\u003eSunsynk High Voltage Series Li‑ion Rack Mount System datasheet.\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/jcsolarpanels.co.za\/wp-content\/uploads\/2022\/09\/Sunsynk_ThreePhaseHI-25-50K_UserManual_v1_English1.pdf?srsltid=AfmBOooDnUheDspAaNmY7H7CPmcUoUUuGcCQG4fVPdUV8izbaDimQirI\" rel=\"noopener\" style=\"color: rgb(43, 0, 255);\" target=\"_blank\"\u003eSunsynk installation and user manuals for the three‑phase hybrid inverters.\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"%20Tatiana%20Boiarova%2011:56%E2%80%AFAM%20(5%20minutes%20ago)%20to%20me%20%20https:\/\/cdn.shopify.com\/s\/files\/1\/0619\/6428\/8220\/files\/Sunsynk_HIGH_VOLTAGE_SERIES_UserManual_v16_English_2.pdf?v=1734363032\" rel=\"noopener\" style=\"color: rgb(43, 0, 255);\" target=\"_blank\"\u003eSunsynk installation and user manuals for the high‑voltage battery rack.\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Sunsynk","offers":[{"title":"Default Title","offer_id":57599978963326,"sku":"30KW-61.44KWH-SYS","price":19252.27,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/sunsynk-30kw-inverter-and-61.44kwhbattery-_1_1.jpg?v=1782206641","url":"https:\/\/www.energian.co.uk\/products\/sunsynk-c-i-energy-storage-system-with-30-kw-hybrid-hv-inverter-and-61-44-kwh-battery","provider":"Energian","version":"1.0","type":"link"}