{"product_id":"sunsynk-30kw-hv-commercial-3-phase-hybrid-inverter","title":"Sunsynk 30kW HV Commercial 3-phase Hybrid Inverter","description":"\u003cdiv style=\"font-size: 16px; line-height: 1.6;\"\u003e\n\u003c!-- A. PRODUCT TITLE \/ HEADING --\u003e\n\u003ch1 style=\"text-align: center;\"\u003eSunsynk 30kW HV Commercial 3‑Phase Hybrid Inverter\u003c\/h1\u003e\n\u003c!-- B. KEY VALUE PROPOSITION --\u003e\n\u003ch2\u003eKey benefits for commercial sites\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e30kW three‑phase hybrid inverter for integrating solar PV, high‑voltage Li‑ion batteries and the grid in one compact unit – ideal for warehouses, logistics hubs and small industrial sites.\u003c\/li\u003e\n\u003cli\u003eHigh DC and AC ratings with 39kW PV input and 30kW continuous output, helping you offset daytime demand and manage peak loads more effectively.\u003c\/li\u003e\n\u003cli\u003eDesigned to meet key UK and international grid and safety standards, with IP65 protection and intelligent air cooling for reliable operation in tough environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- C. BRIEF DESCRIPTION --\u003e\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe Sunsynk 30kW HV Commercial 3‑Phase Hybrid Inverter (SUNSYNK‑30K‑SG01HP3‑EU‑BM3) is part of Sunsynk’s three‑phase high‑voltage range, sized for commercial and light industrial projects that need stable three‑phase power and intelligent energy management. It links high‑voltage Li‑ion batteries, up to 39kW of PV, and the grid to provide self‑consumption, backup capability and export where permitted.\u003c\/p\u003e\n\u003cp\u003eTypical applications include logistics units, chilled storage, agricultural buildings, workshops and mixed‑use commercial schemes with significant three‑phase loads. For full systems, we recommend installation and commissioning by qualified three‑phase installers or our trusted partners to ensure compliance with G98\/G99 and other local requirements.\u003c\/p\u003e\n\u003c!-- D. KEY FEATURES --\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e30kW rated AC output and UPS power with up to 33kW maximum AC output, supporting substantial three‑phase loads while maintaining power quality.\u003c\/li\u003e\n\u003cli\u003eHigh‑voltage battery input (160–800V) with two battery inputs and 50A+50A charge and discharge current, well‑suited to commercial Li‑ion battery banks.\u003c\/li\u003e\n\u003cli\u003eUp to 39,000W DC PV input across three MPPT trackers (2 strings per tracker), allowing efficient use of larger or multi‑orientation arrays.\u003c\/li\u003e\n\u003cli\u003eIntegrated protection suite including DC Type II \/ AC Type III surge protection, anti‑islanding, residual current monitoring and over‑current\/over‑voltage safeguards.\u003c\/li\u003e\n\u003cli\u003eCertified to major grid and EMC\/safety standards such as G98, G99, VDE4105 and IEC62109‑1\/‑2, helping smooth approval on compliant projects.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- E. TECHNICAL SPECIFICATIONS – DIRECT FROM DATASHEET --\u003e\n\u003ch2\u003eTechnical specifications \u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"text-align: left; width: 100.043%;\"\u003eBattery Input Data\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eBattery Type\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003eLi‑ion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eBattery Voltage Range\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e160~800V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eMax. Charging Current\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e50A+50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eMax. Discharging Current\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e50A+50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eNumber of battery input\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eCharging Strategy for Li‑Ion Battery\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003eSelf‑adaption to BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"text-align: left; width: 100.043%;\"\u003ePV String Input Data\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eMax. DC Input Power\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e39000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eMax. DC Input Voltage\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eStart‑up Voltage\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e180V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eMPPT Range\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e150‑850V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eFull Load DC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e360‑850V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eRated DC Input Voltage\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003ePV Input Current\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e36+36+36A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eMax. PV Isc\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e55+55+55A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eNo. of MPPT Trackers\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eNo. of Strings per MPPT Tracker\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e2+2+2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"text-align: left; width: 100.043%;\"\u003eAC Output Data\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eRated AC Output and UPS Power\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e30000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eMax. AC Output Power\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e33000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003ePeak Power (off grid)\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e1.5 time of rated power, 10 S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eAC Output Rated Current\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e45.5\/43.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eMax. AC Current\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e50\/47.9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eMax. Three‑phase Unbalanced Output Current\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eMax. Continuous AC Pass through\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e200A (applies to series, see datasheet table)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003ePower Factor\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eOutput Frequency and Voltage\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e50\/60Hz; 3L\/N\/PE 220\/380, 230\/400Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eGrid Type\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eTotal Harmonic Distortion (THD)\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e\u0026lt;3% (of nominal power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eDC injection current (mA)\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e\u0026lt;0.5%In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"text-align: left; width: 100.043%;\"\u003eEfficiency\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eMax. Efficiency\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e97.60% (series value)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eEuro Efficiency\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e97.00% (series value)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eMPPT Efficiency\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e\u0026gt;99% (series value)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"text-align: left; width: 100.043%;\"\u003eProtection\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003ePV Input Lightning Protection\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eAnti‑islanding Protection\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003ePV String Input Reverse Polarity Protection\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eInsulation Resistor Detection\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eResidual Current Monitoring Unit\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eOutput Over Current Protection\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eOutput Shorted Protection\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eOutput Over Voltage Protection\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003eDC Type II \/ AC Type III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eBattery Over Current Protection\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003eFuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"text-align: left; width: 100.043%;\"\u003eCertifications and Standards\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eGrid Regulation\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003eVDE4105, IEC61727\/62116, VDE0126, AS4777.2, CEI 0 21, EN50549‑1, G98, G99, C10‑11, UNE217002, NBR16149\/NBR16150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eEMC\/Safety Regulation\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003eIEC62109‑1\/‑2, NBT32004‑2018, EN61000‑6‑1, EN61000‑6‑2, EN61000‑6‑3, EN61000‑6‑4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"text-align: left; width: 100.043%;\"\u003eGeneral Data\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e‑40~60 ºC, \u0026gt;45 ºC Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eCooling\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003eIntelligent air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eNoise\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e≤65 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eCommunication with BMS\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003eRS485; CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e88kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eSize\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e527W×894H×294D mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eProtection Degree\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eInstallation Style\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003eWall‑mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.9236%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"width: 31.1198%;\"\u003e5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- DOCUMENTS SECTION --\u003e\n\u003ch2\u003eDocuments available for download\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.sunsynk.com\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eSunsynk three‑phase hybrid inverter series datasheet (29.9–50kW, including 30kW model)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/manuals.plus\/m\/6e01639bbf1813a98470568ebcfaddb49efbc7dbc7b0e0e99c199660c080fdc0\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eSunsynk three‑phase hybrid inverter user \/ installation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- SHIPPING \u0026 SUPPORT --\u003e\n\u003ch2\u003eShipping and UK expert support\u003c\/h2\u003e\n\u003cp\u003eShipping is available to the UK, Ireland, Africa, the Caribbean and worldwide. If a shipping rate is not shown at checkout, please contact us on +44 2080640335 or \u003ca href=\"mailto:info@energian.co.uk\"\u003einfo@energian.co.uk\u003c\/a\u003e for a quote.\u003c\/p\u003e\n\u003cp\u003eUK‑based expert support is available by phone, email or live chat for product selection, system design checks and commissioning guidance. For this 30kW HV commercial 3‑phase hybrid inverter we strongly recommend installation and sign‑off by qualified three‑phase installers or our trusted partners to ensure safe operation and compliance with local grid regulations.\u003c\/p\u003e\n\u003cp\u003eYou are also welcome to visit our office for an in‑person consultation to review your site drawings, load profiles and battery strategy before finalising your design.\u003c\/p\u003e\n\u003c!-- META + ALT (HIDDEN FOR THEME USE) --\u003e\n\u003cdiv style=\"display: none;\"\u003e\n\u003cspan class=\"meta-description\"\u003e Sunsynk 30kW HV Commercial 3‑Phase Hybrid Inverter SUNSYNK‑30K‑SG01HP3‑EU‑BM3 – high‑voltage Li‑ion compatible, 39kW PV input, IP65, for commercial and industrial solar‑battery systems with UK expert support. \u003c\/span\u003e \u003cimg alt=\"Sunsynk 30kW HV commercial three phase hybrid inverter SUNSYNK-30K-SG01HP3-EU-BM3 front view\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Sunsynk","offers":[{"title":"Default Title","offer_id":57546127835518,"sku":"SUNSYNK30K-SG01HP3- EU-BM3","price":4349.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/0001721_Sunsynk-20kW-High-Voltage-Three-Phase-Hybrid-Inverter.webp?v=1781441874","url":"https:\/\/www.energian.co.uk\/products\/sunsynk-30kw-hv-commercial-3-phase-hybrid-inverter","provider":"Energian","version":"1.0","type":"link"}