{"product_id":"solisstorage-evercore-120kwh-battery-and-60kw-hybrid-inverter-system","title":"SolisStorage EverCore 120kWh Battery and 60kW Hybrid Inverter System","description":"\u003c!-- SEO title: SolisStorage EverCore 120kWh Battery and 60kW Hybrid Inverter System | Energian --\u003e\n\u003cdiv class=\"energian-pdp\" style=\"font-family: Helvetica,Arial,sans-serif; font-size: 18px; color: #333; line-height: 1.65; max-width: 900px; margin: 0 auto;\"\u003e\n\u003ch1 style=\"text-align: center;\"\u003e\u003cstrong\u003eSolisStorage EverCore 120kWh Battery and 60kW Hybrid Inverter System\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eOne outdoor cabinet holds 119.2kWh of usable LFP storage, a 60kW three-phase hybrid inverter and up to 100kW of solar input.\u003c\/li\u003e\n\u003cli\u003eKeeps critical loads running in a grid outage, with backup switchover in under 10ms.\u003c\/li\u003e\n\u003cli\u003eBuilt-in air conditioning plus layered fire suppression: aerosol, explosion relief valve and fire water inlet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSolisStorage EverCore 120kWh battery and 60kW hybrid inverter system\u003c\/h2\u003e\n\u003cp\u003eThe SolisStorage EverCore 120kWh battery and 60kW hybrid inverter system (EverCore-120kWh-60kW-NV) pairs a 120.6kWh LFP battery cabinet with a Solis S6-EH3P60K-H inverter. It stores solar or off-peak grid energy, cuts peak demand and backs up three-phase loads. Battery management, monitoring and connections for grid, load and a diesel generator are built in.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSix 20.1kWh battery packs built from 3.2V \/ 314Ah LFP cells, rated for 8,000 cell cycles (cell manufacturer data, 25°C, 0.5P, 70% SOH).\u003c\/li\u003e\n\u003cli\u003eRated at 60kW \/ 60kVA on-grid. Backup output can briefly reach 1.5× rated power for 10 seconds or 1.6× for 2 seconds.\u003c\/li\u003e\n\u003cli\u003eFour MPPTs and 8 PV strings, 1,000V maximum input and a 150–850V MPPT range.\u003c\/li\u003e\n\u003cli\u003eOff-grid parallel operation of up to 10 units, with a dedicated GEN port for a diesel generator.\u003c\/li\u003e\n\u003cli\u003eSolisCloud app setup over Bluetooth, plus WiFi, LAN, CAN, RS485, DRM and dry contacts (4G optional).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhere to use\u003c\/h2\u003e\n\u003cp\u003eThis system suits three-phase commercial and industrial sites. Examples include logistics depots, cold stores, farms, workshops, factories, schools and EV charging hubs.\u003c\/p\u003e\n\u003cp\u003eTypical uses are solar self-consumption, peak shaving, time-of-use tariff shifting, backup for critical loads, and off-grid or weak-grid sites running alongside a generator.\u003c\/p\u003e\n\u003ch3\u003eInstallation and site requirements\u003c\/h3\u003e\n\u003cp\u003eThe system is not plug-and-play. The cabinet and inverter ship separately and are assembled on site. Lifting needs a crane or forklift rated for at least 3 tonnes. Energian can arrange design, installation and commissioning through trusted partners.\u003c\/p\u003e\n\u003cp\u003eInstall outdoors on a level, solid base at least 200mm high. Keep at least 1,200mm behind the cabinet and about 2,000mm clear in front. Grid connection needs DNO approval, and an external ATS is needed if you want a bypass. EverCore is not a UPS.\u003c\/p\u003e\n\u003cp class=\"notice\"\u003eSolar panels, mounting, cabling, switchgear and grounding are not included. They can be quoted to suit your site.\u003c\/p\u003e\n\u003ch2\u003eSolisStorage EverCore 120kWh \/ 60kW technical specifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eEverCore-120kWh-60kW-NV\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSystem\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated energy capacity\u003c\/td\u003e\n\u003ctd\u003e120.6kWh (manual: 120.576kWh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsable energy capacity\u003c\/td\u003e\n\u003ctd\u003e119.2kWh (30–35°C, 0.3C, 100% DOD, within one month of manufacture)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal charging \/ discharging power\u003c\/td\u003e\n\u003ctd\u003e60kW \/ 60kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. cycle rate\u003c\/td\u003e\n\u003ctd\u003e0.5P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. cycle efficiency\u003c\/td\u003e\n\u003ctd\u003e89% (cell test at 25 ±2°C, 0.5P, AC output 380 or 400Vac)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e1,250 × 2,030 × 1,540mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions without inverter (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e950 × 2,030 × 1,540mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1,630kg (cabinet) + 73kg (inverter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature range\u003c\/td\u003e\n\u003ctd\u003e-25 to +55°C (manual: charging 0 to +55°C, discharging -25 to +55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature range\u003c\/td\u003e\n\u003ctd\u003e0 to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransportation temperature\u003c\/td\u003e\n\u003ctd\u003e-30 to +55°C; humidity ≤85% (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity range\u003c\/td\u003e\n\u003ctd\u003e≤95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. operation altitude\u003c\/td\u003e\n\u003ctd\u003e4,000m (derating above 2,000m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem temperature control mode\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade air-conditioning (cabinet); air cooling (pack); intelligent fan-cooling (inverter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire suppression mode\u003c\/td\u003e\n\u003ctd\u003eDefault: aerosol, explosion relief valve, fire water inlet, audible and visual alarm. Optional: flammable gas detector, explosion relief panel, explosion-proof exhaust fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire detection\u003c\/td\u003e\n\u003ctd\u003eSmoke detector and temperature detector (standard); aerosol releases at 170 ±5°C cabinet temperature; DN65 fire water inlet connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress protection\u003c\/td\u003e\n\u003ctd\u003eIP55 (cabinet) + IP66 (inverter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti-corrosion class (battery cabinet)\u003c\/td\u003e\n\u003ctd\u003eC4 \/ C5 (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti-corrosion class (inverter)\u003c\/td\u003e\n\u003ctd\u003eC5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise (rated operating condition)\u003c\/td\u003e\n\u003ctd\u003e70dB(A) at 1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLightning protection\u003c\/td\u003e\n\u003ctd\u003eType II (AC port), Type II (PV \u0026amp; battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection mode\u003c\/td\u003e\n\u003ctd\u003eAnti-islanding protection, residual current detection, insulation resistance detection, AC overcurrent protection, AC cable connection protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary power supply\u003c\/td\u003e\n\u003ctd\u003e220Vac, approx. 2.3kW (taken from the inverter backup port)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication protocol (cabinet)\u003c\/td\u003e\n\u003ctd\u003eTCP\/IP, CAN, RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification standards (datasheet)\u003c\/td\u003e\n\u003ctd\u003eIEC 62619, IEC 61000-6-2\/4, IEC 62040, IEC 63056, IEC 62477, UN38.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance standards (manual)\u003c\/td\u003e\n\u003ctd\u003eUN38.3, IEC 62619, IEC 60730-1, IEC 63056, IEC 62477-1, IEC 61000-6-2 \/ IEC 61000-6-4, UN3480\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eBattery\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell type\u003c\/td\u003e\n\u003ctd\u003eLFP 3.2V \/ 314Ah (EVE MB31, 5.6 ±0.2kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell cycle life\u003c\/td\u003e\n\u003ctd\u003e8,000 (cell manufacturer data at 25 ±2°C, 0.5P charge and discharge, SOH = 70%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem battery configuration\u003c\/td\u003e\n\u003ctd\u003e1P120S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e384V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating voltage range\u003c\/td\u003e\n\u003ctd\u003e348–432V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated DC current\u003c\/td\u003e\n\u003ctd\u003e157A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of battery packs\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery pack model\u003c\/td\u003e\n\u003ctd\u003ePACK-1P20S-314-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery pack capacity\u003c\/td\u003e\n\u003ctd\u003e20.1kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery pack rated voltage \/ range\u003c\/td\u003e\n\u003ctd\u003e64V \/ 58–72V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery pack charge and discharge rate\u003c\/td\u003e\n\u003ctd\u003e≤0.5C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery pack weight\u003c\/td\u003e\n\u003ctd\u003e138kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery pack dimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e435 × 230 × 904mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery pack ingress protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBalancing mode\u003c\/td\u003e\n\u003ctd\u003ePassive cell balancing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePack communications port\u003c\/td\u003e\n\u003ctd\u003eCAN 2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eInverter\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter model\u003c\/td\u003e\n\u003ctd\u003eS6-EH3P60K-H(21A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output power\u003c\/td\u003e\n\u003ctd\u003e60kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. apparent output power (on-grid)\u003c\/td\u003e\n\u003ctd\u003e60kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated grid voltage\u003c\/td\u003e\n\u003ctd\u003e3\/N\/PE, 220V \/ 380V; 3\/N\/PE, 230V \/ 400V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated grid frequency\u003c\/td\u003e\n\u003ctd\u003e50Hz \/ 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC grid frequency range\u003c\/td\u003e\n\u003ctd\u003e45–55Hz \/ 55–65Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current\u003c\/td\u003e\n\u003ctd\u003e91.2A \/ 86.6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. apparent output power (off-grid)\u003c\/td\u003e\n\u003ctd\u003e1.5 × rated power, 10s; 1.6 × rated power, 2s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBack-up switch time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower factor\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;0.99 (0.8 leading – 0.8 lagging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHDi \/ THDv (at linear load)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;2% \/ \u0026lt;3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. usable PV input power\u003c\/td\u003e\n\u003ctd\u003e100kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended max. PV array size\u003c\/td\u003e\n\u003ctd\u003e100kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. input voltage\u003c\/td\u003e\n\u003ctd\u003e1,000V (reduces above 2,000m: 981V at 3,000m, 925V at 3,500m, 875V at 4,000m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStart-up voltage\u003c\/td\u003e\n\u003ctd\u003e180V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT voltage range\u003c\/td\u003e\n\u003ctd\u003e150–850V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. input current\u003c\/td\u003e\n\u003ctd\u003e4 × 42A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. short circuit current\u003c\/td\u003e\n\u003ctd\u003e4 × 60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT number \/ max. input strings number\u003c\/td\u003e\n\u003ctd\u003e4 \/ 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eStandard: WiFi + LAN + Bluetooth, CAN-BMS × 2, CAN-Parallel × 2, RS485-Meter, RS485, DRM, DI × 3, DO × 3. Optional: 4G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. parallel quantity (off-grid)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC ports\u003c\/td\u003e\n\u003ctd\u003eGrid, Backup (user load), GEN (diesel generator)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eThermal management (air conditioner)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR134a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerating \/ heating capacity\u003c\/td\u003e\n\u003ctd\u003e3,200W \/ 1,000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (refrigerating \/ heating)\u003c\/td\u003e\n\u003ctd\u003e1,600W \/ 1,200W at 50Hz; 1,800W \/ 1,300W at 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage \/ frequency\u003c\/td\u003e\n\u003ctd\u003e220Vac ±15% \/ 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eInstallation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFoundation\u003c\/td\u003e\n\u003ctd\u003eConcrete or level ground, foundation height ≥200mm; load capacity 1.5 × n tonnes (n = number of units); 4 fixing points with M12 bolts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearances\u003c\/td\u003e\n\u003ctd\u003eBack to wall ≥1,200mm; front to wall 2,000mm recommended; back to back ≥500mm; facing units ≥2,500mm; inverter side ≥500mm (follow local fire authority requirements)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding\u003c\/td\u003e\n\u003ctd\u003eEquipment continuity \u0026lt;0.1Ω; system grounding resistance ≤4Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended grid cable\u003c\/td\u003e\n\u003ctd\u003eL1\/L2\/L3\/N 50mm²; PE 25mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended generator cable\u003c\/td\u003e\n\u003ctd\u003e16mm² (A\/B\/C\/N\/PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifting\u003c\/td\u003e\n\u003ctd\u003eLifting equipment \u0026gt;3t, 4 cables \u0026gt;1m, acceleration ≤0.2g; forklift and crane load capacity ≥3,000kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupplied accessories\u003c\/td\u003e\n\u003ctd\u003eSun shade, left and right side panels, front panel, bottom panel, 10 × M6×12 stainless steel screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003eDocuments available for download\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Energian-ever-data-20261010.pdf?v=1791653573\" target=\"_blank\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\"\u003eSolisStorage EverCore datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Energian-ever-manual-20261010.pdf?v=1791653575\" rel=\"noopener\" style=\"color: rgb(43, 0, 255);\" target=\"_blank\"\u003eSolisStorage EverCore user manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Energian-ever-qim-20261010.pdf?v=1791653575\" rel=\"noopener\" style=\"color: rgb(43, 0, 255);\" target=\"_blank\"\u003eSolisStorage EverCore quick installation manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eShipping\u003c\/h2\u003e\n\u003cp\u003eShipping is available to the UK, Ireland, Africa, the Caribbean and worldwide. If a shipping rate is not shown at checkout, call \u003ca href=\"tel:+442080640335\"\u003e+44 20 8064 0335\u003c\/a\u003e or email \u003ca href=\"mailto:info@energian.co.uk\"\u003einfo@energian.co.uk\u003c\/a\u003e for a quote. Delivery, unloading and site access are agreed for each order.\u003c\/p\u003e\n\u003ch2\u003eUK expert support\u003c\/h2\u003e\n\u003cp\u003eOur UK team can help you size an EverCore system, plan the PV array, generator and grid connection, and arrange installation. Contact us by \u003ca href=\"tel:+442080640335\"\u003ephone\u003c\/a\u003e, \u003ca href=\"mailto:info@energian.co.uk\"\u003eemail\u003c\/a\u003e or live chat, or visit our office for an in-person consultation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\n.energian-pdp h1{font-size:30px;line-height:1.25;margin:0 0 20px;}\n.energian-pdp h2{font-size:25px;line-height:1.3;margin:28px 0 14px;}\n.energian-pdp h3{font-size:21px;line-height:1.35;margin:22px 0 12px;}\n.energian-pdp p{margin:0 0 16px;}.energian-pdp ul{padding-left:24px;margin:0 0 20px;}.energian-pdp li{margin-bottom:8px;}\n.energian-pdp table{width:100%;border-collapse:collapse;font-size:16px;line-height:1.5;margin-bottom:18px;}\n.energian-pdp th,.energian-pdp td{padding:10px 12px;border:1px solid #ddd;text-align:left;vertical-align:top;}\n.energian-pdp th{background:#f2f5f7;}.energian-pdp a{color:#176b95;text-decoration:underline;}\n.energian-pdp .notice{padding:16px;background:#f5f7f8;border-left:4px solid #176b95;}\n\u003c\/style\u003e","brand":"Solis","offers":[{"title":"Default Title","offer_id":58528947044734,"sku":"SOL-EC-120KWH-60KW-NV-C5-PRO","price":30528.36,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/SOL-EVERCORE-100KWH-50KW-NV-C5-PRO.jpg?v=1783439494","url":"https:\/\/www.energian.co.uk\/products\/solisstorage-evercore-120kwh-battery-and-60kw-hybrid-inverter-system","provider":"Energian","version":"1.0","type":"link"}