{"product_id":"solis-s6-eh3p40k-h-40-0kw-hv-3-phase-hybrid-inverter","title":"Solis S6-EH3P40K-H 40.0kW HV 3-Phase Hybrid Inverter","description":"\u003cdiv style=\"font-size: 16px; line-height: 1.6;\"\u003e\n\u003c!-- A. Product Title \/ Heading --\u003e\n\u003ch1 style=\"text-align: center;\"\u003e\u003cstrong\u003eSolis S6-EH3P40K-H 40.0kW 3-Phase HV Hybrid Inverter\u003c\/strong\u003e\u003c\/h1\u003e\n\u003c!-- B. Key value proposition --\u003e\n\u003cul\u003e\n\u003cli\u003e40kW three-phase hybrid inverter combining solar PV, high-voltage battery, grid and generator in one system for large commercial sites, farms and public-sector facilities.\u003c\/li\u003e\n\u003cli\u003eFast backup changeover and generator compatibility to keep essential loads running during grid outages.\u003c\/li\u003e\n\u003cli\u003eMultiple MPPTs with high input current capability, wide voltage window and IP66 rating for demanding UK and overseas environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- C. Brief Description --\u003e\n\u003cp\u003eThe Solis S6-EH3P40K-H is a 40.0kW three-phase high voltage hybrid inverter designed for projects that need dependable on-grid and off-grid operation with substantial battery storage. It supports large PV arrays, high-voltage Li-ion batteries and generator input, with rapid backup switching to protect critical loads during power cuts. This makes it a strong choice for agricultural sites, larger commercial premises, light industrial units and public-sector buildings with three-phase supplies.\u003c\/p\u003e\n\u003c!-- D. Key features --\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e40kW three-phase hybrid inverter with 40kVA output for 3\/N\/PE 380\/400V systems, compliant with G99 and other major grid codes.\u003c\/li\u003e\n\u003cli\u003eHigh-voltage Li-ion battery support with high charge \/ discharge power and CAN\/RS485 communication for compatible BMS.\u003c\/li\u003e\n\u003cli\u003eHigh DC input power capability, wide MPPT voltage range and high input current for large, modern PV arrays.\u003c\/li\u003e\n\u003cli\u003eGenerator-compatible with fast backup switch time and strong surge capability for motor and pump loads.\u003c\/li\u003e\n\u003cli\u003eIP66 enclosure, intelligent fan cooling and a wide operating temperature range for tough site conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- E. Technical specifications --\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003ch3\u003eInverter type and applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModel: Solis S6-EH3P40K-H (S6-EH3P(30–50)K-H series).\u003c\/li\u003e\n\u003cli\u003eType: Three-phase high voltage hybrid inverter, transformerless topology.\u003c\/li\u003e\n\u003cli\u003eTypical applications: Larger commercial, agricultural, light industrial and public-sector buildings with three-phase supplies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAC output – grid side\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated AC output power: 40kW.\u003c\/li\u003e\n\u003cli\u003eMax. apparent output power: 40kVA.\u003c\/li\u003e\n\u003cli\u003eRated grid voltage: 3\/N\/PE, typically 230\/400V (see datasheet for full range).\u003c\/li\u003e\n\u003cli\u003eRated grid frequency: 50Hz \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003eRated grid output current: per-phase current as specified in the manufacturer datasheet for the 40kW model.\u003c\/li\u003e\n\u003cli\u003eMax. output current: as specified in the S6-EH3P-30–50K-H datasheet.\u003c\/li\u003e\n\u003cli\u003ePower factor: greater than 0.99, adjustable 0.8 leading to 0.8 lagging.\u003c\/li\u003e\n\u003cli\u003eTHDi: low total harmonic distortion at linear load.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAC output – backup side\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated backup output power: 40kW.\u003c\/li\u003e\n\u003cli\u003eMax. apparent backup power: up to 2 × rated power for short durations (see datasheet for exact timing).\u003c\/li\u003e\n\u003cli\u003eBackup output voltage: 3\/N\/PE, matching grid nominal voltage.\u003c\/li\u003e\n\u003cli\u003eBackup frequency: 50Hz \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003eBackup rated output current: as specified in the datasheet for the 40kW model.\u003c\/li\u003e\n\u003cli\u003eBackup switch time: typically under 10ms for UPS-style transfer.\u003c\/li\u003e\n\u003cli\u003eMax. allowable phase imbalance: supports high phase imbalance on grid and backup ports.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAC input – grid and generator\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGrid input voltage range: wide three-phase range suitable for European grids (see datasheet for exact values).\u003c\/li\u003e\n\u003cli\u003eMax. grid input current: as specified for 40kW model.\u003c\/li\u003e\n\u003cli\u003eRated grid frequency: 50Hz \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003eFrequency range: typical utility ranges around nominal frequency.\u003c\/li\u003e\n\u003cli\u003eGenerator max. input power: sized to support 40kW backup capability (see datasheet for recommended generator rating).\u003c\/li\u003e\n\u003cli\u003eGenerator max. input current and frequency: per manufacturer specification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePV input (DC side)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRecommended max. PV array size: high DC-to-AC oversizing ratio as stated in S6-EH3P(30–50)K-H datasheet for 40kW unit.\u003c\/li\u003e\n\u003cli\u003eMax. usable PV input power: as specified for the 40kW model.\u003c\/li\u003e\n\u003cli\u003eMax. DC input voltage: 1000V.\u003c\/li\u003e\n\u003cli\u003eRated DC voltage: according to datasheet for optimum MPPT operation.\u003c\/li\u003e\n\u003cli\u003eStart-up voltage: as per S6-EH3P-30–50K-H datasheet.\u003c\/li\u003e\n\u003cli\u003eMPPT voltage range: wide window to suit long strings (see datasheet for exact range).\u003c\/li\u003e\n\u003cli\u003eNumber of MPPTs \/ strings: multiple MPPT trackers with several inputs, as specified for 40kW model.\u003c\/li\u003e\n\u003cli\u003eMax. input current per MPPT: high current capability for modern high-output modules.\u003c\/li\u003e\n\u003cli\u003eMax. short-circuit current per MPPT: as per manufacturer datasheet.\u003c\/li\u003e\n\u003cli\u003ePV connection: MC4 or MC4-compatible connectors.\u003c\/li\u003e\n\u003cli\u003eIntegrated DC switch: yes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBattery input\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBattery type: Li-ion high voltage with compatible BMS.\u003c\/li\u003e\n\u003cli\u003eBattery voltage range: wide HV range as specified in S6-EH3P(30–50)K-H datasheet.\u003c\/li\u003e\n\u003cli\u003eMax. charge \/ discharge power: up to 40kW, subject to battery capability and configuration.\u003c\/li\u003e\n\u003cli\u003eMax. charge \/ discharge current: as specified for the 40kW model.\u003c\/li\u003e\n\u003cli\u003eBattery communication: CAN \/ RS485.\u003c\/li\u003e\n\u003cli\u003eBattery connection: OT terminals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEfficiency\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMax. inverter efficiency: high peak efficiency in the upper 90% range.\u003c\/li\u003e\n\u003cli\u003eEuropean efficiency: high EU efficiency as per datasheet.\u003c\/li\u003e\n\u003cli\u003ePV to battery max. efficiency: high round-trip efficiency within the hybrid path.\u003c\/li\u003e\n\u003cli\u003eBattery to AC max. efficiency: high conversion efficiency for discharge to loads.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProtection and compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAnti-islanding, output overcurrent, short-circuit, DC reverse-polarity, PV overvoltage and battery reverse protection.\u003c\/li\u003e\n\u003cli\u003eIntegrated AFCI 2.0 (arc-fault protection) optional or standard as per datasheet.\u003c\/li\u003e\n\u003cli\u003eIngress protection rating: IP66.\u003c\/li\u003e\n\u003cli\u003eGrid standards: EN 50549, G99 and other regional codes listed in the UK \/ EU datasheet.\u003c\/li\u003e\n\u003cli\u003eSafety \/ EMC standards: IEC\/EN 62109 series and IEC\/EN 61000-6-1\/-2\/-3\/-4.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eUser interface and communications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisplay: large LCD display with local control keys and status indicators.\u003c\/li\u003e\n\u003cli\u003eCommunications: CAN, RS485, Ethernet; optional Wi-Fi, cellular and LAN dataloggers for remote monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical and environmental\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions (W × H × D): as specified in S6-EH3P-30–50K-H datasheet for 40kW unit.\u003c\/li\u003e\n\u003cli\u003eWeight: as specified for the 40kW model.\u003c\/li\u003e\n\u003cli\u003eSelf-consumption (night): low standby consumption.\u003c\/li\u003e\n\u003cli\u003eOperating temperature range: typically −25 to +60°C with possible derating at higher temperatures.\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 0–95% (non-condensing).\u003c\/li\u003e\n\u003cli\u003eCooling: intelligent fan cooling.\u003c\/li\u003e\n\u003cli\u003eTypical noise emission: within typical plant-room noise thresholds (see datasheet for dB(A) value).\u003c\/li\u003e\n\u003cli\u003eMax. operating altitude: up to 2000m, subject to any derating conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- F. Shipping and UK support --\u003e\n\u003ch2\u003eShipping and UK expert support\u003c\/h2\u003e\n\u003cp\u003eShipping is available to the UK, Ireland, Africa, the Caribbean and worldwide. If the shipping rate is not shown at checkout, please contact us on +44 2080640335 or \u003ca href=\"mailto:info@energian.co.uk\"\u003einfo@energian.co.uk\u003c\/a\u003e for a quote.\u003c\/p\u003e\n\u003cp\u003eThis is a fixed, hard-wired three-phase hybrid inverter and is not supplied as a plug-and-play product. Energian recommends installation and commissioning by a suitably qualified electrician or trusted installer partner to meet UK wiring regulations and grid-connection rules.\u003c\/p\u003e\n\u003cp\u003eUK expert support is available – contact us by phone, email or live chat, or visit our office for in-person consultation on system design, battery pairing, generator integration and DNO applications.\u003c\/p\u003e\n\u003c!-- Documents section --\u003e\n\u003ch2\u003eDocuments available for download\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"\/files\/Solis_datasheet_S6-EH3P-30-50-K-H_GBR_V15_202507.pdf\" target=\"_blank\"\u003eSolis S6-EH3P(30–50)K-H Datasheet – GBR\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"\/files\/Solis_Manual_S6-EH3P-12-20-kW.pdf\" target=\"_blank\"\u003eSolis S6-EH3P Series Installation and User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Ginlong","offers":[{"title":"Default Title","offer_id":56625570316670,"sku":"SOL-S6-EH3P40K-H","price":4748.46,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/SOL-S6-EH3P30K-H_1.jpg?v=1764162312","url":"https:\/\/www.energian.co.uk\/products\/solis-s6-eh3p40k-h-40-0kw-hv-3-phase-hybrid-inverter","provider":"Energian","version":"1.0","type":"link"}