{"product_id":"solis-s6-eh3p30k-h-30-0kw-hv-3-phase-hybrid-inverter","title":"Solis S6-EH3P30K-H 30.0kW HV 3-Phase Hybrid Inverter","description":"\u003cdiv style=\"font-size: 16px; line-height: 1.6;\"\u003e\n\u003c!-- A. Product Title \/ Heading --\u003e\n\u003ch1 style=\"text-align: center;\"\u003e\u003cstrong\u003eSolis S6-EH3P30K-H 30.0kW 3-Phase HV Hybrid Inverter\u003c\/strong\u003e\u003c\/h1\u003e\n\u003c!-- B. Key value proposition --\u003e\n\u003cul\u003e\n\u003cli\u003e30kW three-phase hybrid inverter combining solar PV, high-voltage battery, grid and generator in one system for large commercial sites, farms and public buildings.\u003c\/li\u003e\n\u003cli\u003eFast backup changeover and generator compatibility to keep essential loads running during grid outages.\u003c\/li\u003e\n\u003cli\u003eMultiple MPPTs with high input current capability, wide voltage window and IP66 rating for demanding UK and overseas environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- C. Brief Description --\u003e\n\u003cp\u003eThe Solis S6-EH3P30K-H is a 30.0kW three-phase high voltage hybrid inverter designed for projects that need dependable on-grid and off-grid operation with substantial battery storage. It supports large PV arrays, high-voltage Li-ion batteries and generator input, with rapid backup switching to protect critical loads during power cuts. This makes it an excellent fit for agricultural sites, commercial premises, light industrial units and public-sector facilities with three-phase supplies.\u003c\/p\u003e\n\u003c!-- D. Key features --\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e30kW three-phase hybrid inverter with 30kVA output for 3\/N\/PE 380\/400V systems, compliant with G99 and other major grid codes.\u003c\/li\u003e\n\u003cli\u003eHigh-voltage Li-ion battery support with high charge \/ discharge power and CAN\/RS485 communication for compatible BMS.\u003c\/li\u003e\n\u003cli\u003eHigh DC input power capability, wide MPPT voltage range and high input current for large, modern PV arrays.\u003c\/li\u003e\n\u003cli\u003eGenerator-compatible with fast backup switch time and strong surge capability for motor and pump loads.\u003c\/li\u003e\n\u003cli\u003eIP66 enclosure, intelligent fan cooling and a wide operating temperature range for tough site conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- E. Technical specifications --\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003ch3\u003eInverter type and applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModel: Solis S6-EH3P30K-H (S6-EH3P(30–50)K-H series).\u003c\/li\u003e\n\u003cli\u003eType: Three-phase high voltage hybrid inverter, transformerless topology.\u003c\/li\u003e\n\u003cli\u003eTypical applications: Larger commercial, agricultural, light industrial and public-sector buildings with three-phase supplies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAC output – grid side\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated AC output power: 30kW.\u003c\/li\u003e\n\u003cli\u003eMax. apparent output power: 30kVA.\u003c\/li\u003e\n\u003cli\u003eRated grid voltage: 3\/N\/PE, typically 230\/400V (check datasheet for full range).\u003c\/li\u003e\n\u003cli\u003eRated grid frequency: 50Hz \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003eRated grid output current: per-phase current as specified in manufacturer datasheet for 30kW model.\u003c\/li\u003e\n\u003cli\u003eMax. output current: as specified in manufacturer datasheet for 30kW model.\u003c\/li\u003e\n\u003cli\u003ePower factor: greater than 0.99, adjustable 0.8 leading to 0.8 lagging.\u003c\/li\u003e\n\u003cli\u003eTHDi: low total harmonic distortion at linear load.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAC output – backup side\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated backup output power: 30kW.\u003c\/li\u003e\n\u003cli\u003eMax. apparent backup power: up to 2 × rated power for short durations (see datasheet for exact timing).\u003c\/li\u003e\n\u003cli\u003eBackup output voltage: 3\/N\/PE, matching grid nominal voltage.\u003c\/li\u003e\n\u003cli\u003eBackup frequency: 50Hz \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003eBackup rated output current: as specified in manufacturer datasheet for 30kW model.\u003c\/li\u003e\n\u003cli\u003eBackup switch time: typically under 10ms for UPS-style transfer.\u003c\/li\u003e\n\u003cli\u003eMax. allowable phase imbalance: supports high phase imbalance on grid and backup ports.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAC input – grid and generator\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGrid input voltage range: wide three-phase range suitable for European grids (see datasheet for exact values).\u003c\/li\u003e\n\u003cli\u003eMax. grid input current: as specified for 30kW model in datasheet.\u003c\/li\u003e\n\u003cli\u003eRated grid frequency: 50Hz \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003eFrequency range: typical utility ranges around nominal frequency.\u003c\/li\u003e\n\u003cli\u003eGenerator max. input power: sized to support full 30kW backup capability (see datasheet for recommended generator rating).\u003c\/li\u003e\n\u003cli\u003eGenerator max. input current and frequency: per manufacturer specification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePV input (DC side)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRecommended max. PV array size: high DC-to-AC oversizing ratio, up to the kW value stated in the S6-EH3P(30–50)K-H datasheet.\u003c\/li\u003e\n\u003cli\u003eMax. usable PV input power: as specified for the 30kW model.\u003c\/li\u003e\n\u003cli\u003eMax. DC input voltage: 1000V (typical for the series).\u003c\/li\u003e\n\u003cli\u003eRated DC voltage: according to datasheet for optimum MPPT operation.\u003c\/li\u003e\n\u003cli\u003eStart-up voltage: as per datasheet for S6-EH3P30K-H.\u003c\/li\u003e\n\u003cli\u003eMPPT voltage range: wide window to suit long strings (see datasheet for exact range).\u003c\/li\u003e\n\u003cli\u003eNumber of MPPTs \/ strings: multiple MPPT trackers with several inputs, as specified for 30kW model.\u003c\/li\u003e\n\u003cli\u003eMax. input current per MPPT: high current capability to match modern high-output modules.\u003c\/li\u003e\n\u003cli\u003eMax. short-circuit current per MPPT: as per manufacturer datasheet.\u003c\/li\u003e\n\u003cli\u003ePV connection: MC4 or MC4-compatible connectors.\u003c\/li\u003e\n\u003cli\u003eIntegrated DC switch: yes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBattery input\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBattery type: Li-ion high voltage with compatible BMS.\u003c\/li\u003e\n\u003cli\u003eBattery voltage range: wide HV range as specified in S6-EH3P(30–50)K-H datasheet.\u003c\/li\u003e\n\u003cli\u003eMax. charge \/ discharge power: up to 30kW, subject to battery capability and configuration.\u003c\/li\u003e\n\u003cli\u003eMax. charge \/ discharge current: as specified for the 30kW model.\u003c\/li\u003e\n\u003cli\u003eBattery communication: CAN \/ RS485.\u003c\/li\u003e\n\u003cli\u003eBattery connection: OT terminals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEfficiency\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMax. inverter efficiency: high peak efficiency in the upper 90% range.\u003c\/li\u003e\n\u003cli\u003eEuropean efficiency: high EU efficiency as per datasheet.\u003c\/li\u003e\n\u003cli\u003ePV to battery max. efficiency: high round-trip efficiency within the hybrid path.\u003c\/li\u003e\n\u003cli\u003eBattery to AC max. efficiency: high conversion efficiency for discharge to loads.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProtection and compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAnti-islanding, output overcurrent, short-circuit, DC reverse-polarity, PV overvoltage and battery reverse protection.\u003c\/li\u003e\n\u003cli\u003eIntegrated AFCI 2.0 (arc-fault protection) optional or standard as per datasheet.\u003c\/li\u003e\n\u003cli\u003eIngress protection rating: IP66.\u003c\/li\u003e\n\u003cli\u003eGrid standards: EN 50549, G99 and other regional codes listed in the UK \/ EU datasheet.\u003c\/li\u003e\n\u003cli\u003eSafety \/ EMC standards: IEC\/EN 62109 series and IEC\/EN 61000-6-1\/-2\/-3\/-4.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eUser interface and communications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisplay: large LCD display with local control keys and status indicators.\u003c\/li\u003e\n\u003cli\u003eCommunications: CAN, RS485, Ethernet; optional Wi-Fi, cellular and LAN dataloggers for remote monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical and environmental\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions (W × H × D): per S6-EH3P(30–50)K-H datasheet for 30kW unit.\u003c\/li\u003e\n\u003cli\u003eWeight: as specified for the 30kW model.\u003c\/li\u003e\n\u003cli\u003eSelf-consumption (night): low standby consumption.\u003c\/li\u003e\n\u003cli\u003eOperating temperature range: typically −25 to +60°C with possible derating at higher temperatures.\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 0–95% (non-condensing).\u003c\/li\u003e\n\u003cli\u003eCooling: intelligent fan cooling.\u003c\/li\u003e\n\u003cli\u003eTypical noise emission: under typical plant-room noise thresholds (see datasheet for dB(A) value).\u003c\/li\u003e\n\u003cli\u003eMax. operating altitude: up to 2000m, subject to any derating conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- F. Shipping and UK support --\u003e\n\u003ch2\u003eShipping and UK expert support\u003c\/h2\u003e\n\u003cp\u003eShipping is available to the UK, Ireland, Africa, the Caribbean and worldwide. If the shipping rate is not shown at checkout, please contact us on +44 2080640335 or \u003ca href=\"mailto:info@energian.co.uk\"\u003einfo@energian.co.uk\u003c\/a\u003e for a quote.\u003c\/p\u003e\n\u003cp\u003eThis is a fixed, hard-wired three-phase hybrid inverter and is not supplied as a plug-and-play product. Energian recommends installation and commissioning by a suitably qualified electrician or trusted installer partner to meet UK wiring regulations and grid-connection rules.\u003c\/p\u003e\n\u003cp\u003eUK expert support is available – contact us by phone, email or live chat, or visit our office for in-person consultation on system design, battery pairing, generator integration and DNO applications.\u003c\/p\u003e\n\u003c!-- Documents section --\u003e\n\u003ch2\u003eDocuments available for download\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"\/files\/Solis_datasheet_S6-EH3P(30-50)K-H_GBR_V1,5_202507.pdf\" target=\"_blank\"\u003eSolis S6-EH3P(30–50)K-H Datasheet – GBR\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"\/files\/Solis_Manual_S6-EH3P-12-20-kW.pdf\" target=\"_blank\"\u003eSolis S6-EH3P Series Installation and User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Ginlong","offers":[{"title":"Default Title","offer_id":56625208656254,"sku":"SOL-S6-EH3P30K-H","price":2909.63,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/SOL-S6-EH3P30K-H_1.jpg?v=1764162312","url":"https:\/\/www.energian.co.uk\/products\/solis-s6-eh3p30k-h-30-0kw-hv-3-phase-hybrid-inverter","provider":"Energian","version":"1.0","type":"link"}