{"product_id":"solax-x3-ultra-30-0kw-hv-3-phase-hybrid-inverter","title":"SolaX X3-Ultra 30.0kW HV 3-Phase Hybrid Inverter","description":"\u003cdiv style=\"font-size: 18px; line-height: 1.6;\"\u003e\n\u003c!-- A. Product Title \/ Heading --\u003e\n\u003ch1 style=\"text-align: center;\"\u003eSolaX X3-Ultra 30.0kW HV 3‑Phase Hybrid Inverter\u003c\/h1\u003e\n\u003c!-- B. Key value proposition --\u003e\n\u003ch2\u003eKey benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e30kW three‑phase C\u0026amp;I hybrid inverter for larger commercial and industrial systems combining PV generation and high‑voltage lithium batteries.\u003c\/li\u003e\n\u003cli\u003eSupports up to 200% PV oversizing, 110% AC output and 200% EPS overload for 10 seconds, helping manage demanding site loads and short peaks.\u003c\/li\u003e\n\u003cli\u003eIP66‑rated, with Type II surge protection on AC and DC sides plus optional AFCI, suited to exposed plant rooms, rooftops and service yards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- C. Brief Description --\u003e\n\u003ch2\u003eBrief description\u003c\/h2\u003e\n\u003cp\u003eThe SolaX X3‑Ultra 30.0kW HV 3‑Phase Hybrid Inverter is designed for three‑phase commercial and industrial projects that need a single platform for PV, battery storage and backup power. It offers smart management features including UPS‑level switchover, built‑in shadow tracking and smart load control, making it a practical choice for logistics hubs, small factories, retail sites and mixed‑use buildings. With support for up to 10 units in parallel and microgrid\/generator functions, it can scale with project needs and integrate into wider energy strategies.\u003c\/p\u003e\n\u003c!-- D. Key features --\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThree‑phase C\u0026amp;I hybrid inverter with 30kW rated output and EPS backup operation when paired with batteries.\u003c\/li\u003e\n\u003cli\u003eMax. 10 inverters in parallel for both on‑grid and off‑grid operation, plus microgrid and generator support for versatile system design.\u003c\/li\u003e\n\u003cli\u003eMax. 36A PV input per MPPT across three trackers, optimised for high‑power solar panels and flexible string layouts.\u003c\/li\u003e\n\u003cli\u003eSingle‑unit UPS‑level switchover time below 10ms, with loads response time within 0.3s for smart loads such as heat pumps and EV chargers.\u003c\/li\u003e\n\u003cli\u003eVPP‑ready with compatibility options including OpenADR, IEEE2030.5, FCAS and API (feature to be upgraded in future firmware).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- E. Technical specifications – SolaX X3‑ULT‑30K and common data --\u003e\n\u003ch2\u003eTechnical specifications \u003c\/h2\u003e\n\u003ch3\u003ePV input\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. recommended PV array power\u003c\/td\u003e\n\u003ctd\u003e60 kWp (X3‑ULT‑30K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. PV input voltage\u003c\/td\u003e\n\u003ctd\u003e1000 V (①)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated PV input voltage\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation voltage range\u003c\/td\u003e\n\u003ctd\u003e120 ~ 950 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT voltage range\u003c\/td\u003e\n\u003ctd\u003e160 ~ 950 V (②)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStart-up voltage\u003c\/td\u003e\n\u003ctd\u003e200 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. of MPP trackers \/ strings per MPP tracker\u003c\/td\u003e\n\u003ctd\u003e3 \/ (2 \/ 2 \/ 2) (X3‑ULT‑30K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. input current per MPPT\u003c\/td\u003e\n\u003ctd\u003e36 A \/ 36 A \/ 36 A (X3‑ULT‑30K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. input short circuit current per MPPT\u003c\/td\u003e\n\u003ctd\u003e45 A \/ 45 A \/ 45 A (X3‑ULT‑30K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAC input \u0026amp; output (on‑grid)\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output power\u003c\/td\u003e\n\u003ctd\u003e30000 W (AS4777 29999 W, VDE4105 29900 W) (X3‑ULT‑30K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current\u003c\/td\u003e\n\u003ctd\u003e43.5 A (X3‑ULT‑30K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output apparent power\u003c\/td\u003e\n\u003ctd\u003e30000 VA (AS4777 29999 VA, VDE4105 29900 VA) (X3‑ULT‑30K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output continuous current\u003c\/td\u003e\n\u003ctd\u003e43.5 A (X3‑ULT‑30K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated AC voltage\u003c\/td\u003e\n\u003ctd\u003e3 \/ N \/ PE, 220 \/ 380 V; 3 \/ N \/ PE, 230 \/ 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. AC input apparent power\u003c\/td\u003e\n\u003ctd\u003e30000 VA (X3‑ULT‑30K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. AC input current\u003c\/td\u003e\n\u003ctd\u003e43.5 A (X3‑ULT‑30K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated AC frequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustable power factor range\u003c\/td\u003e\n\u003ctd\u003e~ 1 (0.8 lagging to 0.8 leading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHDi (rated power)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBattery\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd\u003eLithium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery voltage range\u003c\/td\u003e\n\u003ctd\u003e120 ~ 800 V (③④)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. charge \/ discharge current\u003c\/td\u003e\n\u003ctd\u003e60 A (30 A × 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEPS (off‑grid) output (with battery)\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated EPS output voltage, frequency\u003c\/td\u003e\n\u003ctd\u003e230 V \/ 400 V, 50 Hz \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated EPS output power\u003c\/td\u003e\n\u003ctd\u003e30000 VA (30K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak EPS output power\u003c\/td\u003e\n\u003ctd\u003e2 times of rated power, 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitchover time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEfficiency\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. efficiency\u003c\/td\u003e\n\u003ctd\u003e98.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEuropean efficiency\u003c\/td\u003e\n\u003ctd\u003e97.7%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEnvironment limit\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress protection\u003c\/td\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation temperature range\u003c\/td\u003e\n\u003ctd\u003e-35 ~ 60°C (\u0026gt; 45°C derating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. operation altitude\u003c\/td\u003e\n\u003ctd\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e0 ~ 100% RH (condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eMains: III, Battery: II, PV: II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eGeneral\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e696 × 526 × 240 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e47 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling concept\u003c\/td\u003e\n\u003ctd\u003eSmart air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication interfaces\u003c\/td\u003e\n\u003ctd\u003eMeter (RS‑485), DI × 2, DO × 1, Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption (night)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon‑isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eVDE4105, G99, AS4777, EN50549, CEI 0‑21, IEC61727, PEA\/MEA, NRS‑097‑2‑1, RD1699, TOR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProtection\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections\u003c\/td\u003e\n\u003ctd\u003eOver \/ under voltage protection, DC reverse‑polarity protection, Residual current detection, Over temperature protection, DC isolation protection, Grid monitoring, DC injection monitoring, Back feed current monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActive anti‑islanding method\u003c\/td\u003e\n\u003ctd\u003eFrequency shift\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge protection\u003c\/td\u003e\n\u003ctd\u003eDC: Type II, AC: Type II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArc-fault circuit interrupter (AFCI)\u003c\/td\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManufacturer notes\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNote ①\u003c\/td\u003e\n\u003ctd\u003eThe maximum input voltage is the upper limit of the DC voltage. Any higher input DC voltage would probably damage inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNote ②\u003c\/td\u003e\n\u003ctd\u003eInput voltage exceeding the MPPT voltage range may triggers inverter protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNote ③\u003c\/td\u003e\n\u003ctd\u003eCompatible with a minimum of 3 units of HS Series batteries, but if the total voltage of the 3 batteries is less than 127V and there is no PV input, the system will not able to startup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNote ④\u003c\/td\u003e\n\u003ctd\u003eWhen the voltage is below 180V, the inverter will limit the battery current to less than 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- F. Shipping --\u003e\n\u003ch2\u003eShipping\u003c\/h2\u003e\n\u003cp\u003eShipping is available to the UK, Ireland, Africa, the Caribbean and worldwide. If the shipping rate is not shown at checkout, please contact us on \u003ca href=\"tel:+442080640335\"\u003e+44 2080640335\u003c\/a\u003e or \u003ca href=\"mailto:info@energian.co.uk\"\u003einfo@energian.co.uk\u003c\/a\u003e for a tailored shipping quote.\u003c\/p\u003e\n\u003c!-- UK expert support --\u003e\n\u003ch2\u003eUK expert support\u003c\/h2\u003e\n\u003cp\u003eUK expert support is available to help with system design, product selection and technical questions for the SolaX X3‑Ultra 30.0kW HV 3‑Phase Hybrid Inverter. For commercial and industrial projects we recommend installation and commissioning through our trusted partners, ensuring compliance with local grid codes and safe integration of PV, batteries, backup loads and generators.\u003c\/p\u003e\n\u003cp\u003eYou can contact us via phone, email or live chat, or visit our office for an in‑person consultation on your project requirements and hybrid system configuration.\u003c\/p\u003e\n\u003c!-- Documents --\u003e\n\u003ch2\u003eDocuments available for download\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Solax_Datasheet-X3-Ultra.pdf?v=1780841035\" target=\"_blank\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\"\u003eSolaX X3‑Ultra datasheet (includes X3‑ULT‑30)\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"SolaX","offers":[{"title":"Default Title","offer_id":57523754959230,"sku":"SX-363007","price":3265.91,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/x3-ultra.webp?v=1780841381","url":"https:\/\/www.energian.co.uk\/products\/solax-x3-ultra-30-0kw-hv-3-phase-hybrid-inverter","provider":"Energian","version":"1.0","type":"link"}