{"product_id":"solax-x3-hybrid-g4-pro-12-0kw-hv-3-phase-hybrid-inverter","title":"SolaX X3-Hybrid G4 PRO 12.0kW HV 3-Phase Hybrid Inverter","description":"\u003cdiv style=\"font-size: 16px; line-height: 1.6;\"\u003e\n\u003ch1 style=\"text-align: center;\"\u003eSolaX X3-Hybrid G4 PRO 12.0kW HV 3‑Phase Hybrid Inverter\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e12kW three‑phase high‑voltage hybrid inverter for larger commercial and industrial solar‑plus‑storage systems.\u003c\/li\u003e\n\u003cli\u003eThree MPPTs, dual battery ports and microgrid \/ generator modes for flexible design and robust backup.\u003c\/li\u003e\n\u003cli\u003eHigh efficiency, IP66 protection and comprehensive safety features for long‑term use on UK sites.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBrief description\u003c\/h2\u003e\n\u003cp\u003eThe SolaX X3‑Hybrid G4 PRO 12.0kW is a three‑phase residential and light commercial hybrid inverter designed to manage PV generation and high‑voltage lithium battery storage on one platform. It offers 12kW rated output, a wide MPPT range of 110–950V and 20A DC input per MPPT, supporting modern high‑current modules and complex roof layouts.\u003c\/p\u003e\n\u003cp\u003eDual battery ports with a 2‑in‑1 function allow flexible battery expansion and higher charge \/ discharge currents, while microgrid and generator modes enable more advanced backup and islanded operation. Smart scheduling, time‑of‑use control and VPP readiness support intelligent energy management on UK commercial and industrial projects.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e12kW three‑phase hybrid inverter\u003c\/strong\u003e – Rated output apparent power 12000W and 12kVA EPS capability, suitable for larger three‑phase loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible PV design\u003c\/strong\u003e – 24kWp recommended array power, three MPPTs, 20A per tracker and an ultra‑wide 110–950V MPPT range with 200% PV oversizing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual battery ports\u003c\/strong\u003e – Two HV battery ports with up to 50A total charge \/ discharge current using a 2‑in‑1 splitter cable, supporting sizeable battery banks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrong backup performance\u003c\/strong\u003e – Up to 200% EPS output for 10s, three‑phase EPS at 230 \/ 400V and UPS‑level switchover time of less than 10ms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart management and protection\u003c\/strong\u003e – V2X‑ready, VPP‑ready, Type II SPD on AC and DC, optional AFCI and optional Rapid Shutdown, all in an IP66 enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhere to use this inverter\u003c\/h2\u003e\n\u003cp\u003eX3‑Hybrid G4 PRO 12.0kW suits three‑phase sites needing a high‑power hybrid inverter with battery storage, such as logistics depots, workshops, light‑industrial units and larger commercial buildings. It is appropriate for behind‑the‑meter solar storage systems, peak‑shaving, backup for critical loads and microgrid applications where generator integration or complex load profiles are involved.\u003c\/p\u003e\n\u003cp\u003eAs a high‑voltage hybrid inverter with three‑phase EPS and advanced modes, installation and commissioning must be carried out by qualified electricians familiar with SolaX equipment and UK grid codes (e.g. G99). Energian can help design complete systems and arrange installation via trusted UK partners.\u003c\/p\u003e\n\u003ch2\u003eTechnical specifications\u003cem\u003e\u003c\/em\u003e\n\u003c\/h2\u003e\n\u003ch3\u003ePV input\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. recommended PV array power:\u003c\/strong\u003e 24kWp (X3‑HYB‑12.0‑P).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. PV input voltage:\u003c\/strong\u003e 1000V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated PV input voltage:\u003c\/strong\u003e 650V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating voltage range:\u003c\/strong\u003e 110–950V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart‑up voltage:\u003c\/strong\u003e 120V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo. of MPPT trackers \/ strings per MPPT:\u003c\/strong\u003e 3 (1 \/ 1 \/ 1).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. input current per MPPT:\u003c\/strong\u003e 20 \/ 20 \/ 20A DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. input short‑circuit current per MPPT:\u003c\/strong\u003e 25 \/ 25 \/ 25A DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePV oversizing and output:\u003c\/strong\u003e 200% PV oversizing and up to 110% AC output (series feature).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAC input and output (on‑grid)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated output apparent power:\u003c\/strong\u003e 12000W (X3‑HYB‑12.0‑P).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated output current:\u003c\/strong\u003e 17.5A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. output apparent power:\u003c\/strong\u003e 13200VA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. output continuous current:\u003c\/strong\u003e 20.0A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated AC voltage:\u003c\/strong\u003e 3W \/ N \/ PE, 220 \/ 380V AC; 3W \/ N \/ PE, 230 \/ 400V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. AC input apparent power:\u003c\/strong\u003e 21.0kVA (for 10–15kW group; applies to 12kW model).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. AC input current:\u003c\/strong\u003e 32A AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated AC frequency:\u003c\/strong\u003e 50 \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC frequency range:\u003c\/strong\u003e 50 ± 5 \/ 60 ± 5Hz (country‑code dependent).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable power factor range:\u003c\/strong\u003e 1 (‑0.8 to 0.8).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBattery\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery type:\u003c\/strong\u003e Lithium (HV batteries such as SolaX HS Series).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery voltage range:\u003c\/strong\u003e 120–800V DC (compatible with a minimum of 3 HS Series batteries; voltage conditions apply).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. charge \/ discharge current:\u003c\/strong\u003e 50A DC (25 × 2) or 30A DC (single port).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual battery ports and 2‑in‑1 function:\u003c\/strong\u003e Dual battery ports with 25A per port when separate, 30A on a single connection, or 50A total using a 2‑in‑1 splitter cable (sold separately).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEPS (off‑grid) output with battery\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated EPS apparent power:\u003c\/strong\u003e 12kVA (X3‑HYB‑12.0‑P).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak EPS output power:\u003c\/strong\u003e 2 × rated power for 10s (i.e. up to 24kVA for 12kW model).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated EPS output voltage and frequency:\u003c\/strong\u003e 230 \/ 400V AC, 50 \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitchover time:\u003c\/strong\u003e less than 10ms (UPS‑level).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEfficiency\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. efficiency:\u003c\/strong\u003e 98.0%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEuropean efficiency:\u003c\/strong\u003e 97.7%.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironment limits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress protection:\u003c\/strong\u003e IP66.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature range:\u003c\/strong\u003e −35 to +60°C (output derating above 45°C).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. operating altitude:\u003c\/strong\u003e 3000m.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity:\u003c\/strong\u003e 4–100% RH (condensing).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage category:\u003c\/strong\u003e Mains: III; Battery: II; PV: II.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGeneral\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W × H × D):\u003c\/strong\u003e 560 × 503 × 210mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet weight:\u003c\/strong\u003e 38kg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling concept:\u003c\/strong\u003e Natural cooling (lower‑power models) and smart air cooling (higher‑power group including 12kW \/ 15kW).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication interfaces:\u003c\/strong\u003e RS485, CAN, DRM, DI\/DO.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower consumption (night):\u003c\/strong\u003e \u0026lt; 5W.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTopology:\u003c\/strong\u003e Non‑isolated.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProtection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard protections:\u003c\/strong\u003e Over \/ under voltage protection, DC isolation protection, DC reverse‑polarity protection, grid monitoring, DC injection monitoring, back‑feed current monitoring, residual current detection, over‑temperature protection, AC overcurrent protection, AC short‑circuit protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge protection:\u003c\/strong\u003e DC: Type II; AC: Type II.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArc‑fault circuit interrupter (AFCI):\u003c\/strong\u003e Optional.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Rapid Shutdown:\u003c\/strong\u003e Optional Rapid Shutdown function for enhanced safety (series feature).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDocuments available for download\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca rel=\"noopener\" style=\"color: rgb(43, 0, 255);\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/solax-x3-hyb-g4-pro-datasheet-en.pdf?v=1784558852\" target=\"_blank\"\u003eSolaX X3‑HYB G4 PRO – Datasheet.\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/x3-hyb-g4-pro-series-installation-manual-global.pdf?v=1784559005\" target=\"_blank\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\"\u003eSolaX X3‑HYB G4 PRO – Installation Manual.\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eShipping and support\u003c\/h2\u003e\n\u003cp\u003eShipping is available to the UK, Ireland, Africa, the Caribbean and worldwide. If a shipping rate is not shown at checkout, please contact us on +44 20 8064 0335 or \u003ca href=\"mailto:info@energian.co.uk\"\u003einfo@energian.co.uk\u003c\/a\u003e for a quotation.\u003c\/p\u003e\n\u003cp\u003eUK expert support is available – contact us with any questions or support requests via phone, email or live chat, or visit our office for an in‑person consultation about SolaX X3‑Hybrid G4 PRO inverters and wider commercial and industrial energy storage solutions.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"SolaX","offers":[{"title":"Default Title","offer_id":57705948479870,"sku":"X3-HYBRID-12.0-PRO-G4","price":1910.45,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/SolaX-X3-Hybrid-G4.jpg?v=1718194473","url":"https:\/\/www.energian.co.uk\/products\/solax-x3-hybrid-g4-pro-12-0kw-hv-3-phase-hybrid-inverter","provider":"Energian","version":"1.0","type":"link"}