{"product_id":"solax-x3-aelio-60kw-hv-commercial-3-phase-hybrid-inverter","title":"SolaX X3-AELIO 60kW HV Commercial 3-phase Hybrid Inverter","description":"\u003cdiv style=\"font-size: 16px; line-height: 1.6;\"\u003e\n\u003c!-- A. PRODUCT TITLE \/ HEADING --\u003e\n\u003ch1 style=\"text-align: center;\"\u003eSolaX X3‑AELIO 60kW HV Commercial 3‑Phase Hybrid Inverter\u003c\/h1\u003e\n\u003c!-- B. KEY VALUE PROPOSITION --\u003e\n\u003ch2\u003eKey benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e60kW three‑phase hybrid inverter for commercial and industrial sites needing reliable power from solar PV, high‑voltage LFP batteries and the grid in one system.\u003c\/li\u003e\n\u003cli\u003eFlexible configuration with support for up to 10 parallel systems and up to 200% PV oversizing, allowing designs from around 50kW up to 600kW with shared controls.\u003c\/li\u003e\n\u003cli\u003eIP66 protection, high efficiency (up to 98.0%) and rapid 10ms on‑grid\/off‑grid transfer for demanding environments and critical loads.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- C. BRIEF DESCRIPTION --\u003e\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe SolaX X3‑AELIO 60kW HV Commercial 3‑Phase Hybrid Inverter is part of the X3‑AELIO range (49.9kW \/ 50kW \/ 60kW \/ 61kW) designed for larger commercial and industrial applications. It manages energy flows between high‑voltage LFP battery storage, substantial PV arrays and the three‑phase grid, with optional generator integration and support for virtual power plant (VPP) applications.\u003c\/p\u003e\n\u003cp\u003eTypical sites include logistics hubs, food production and cold stores, commercial buildings with critical three‑phase loads, and micro‑grids where fast switchover and extended off‑grid capability are required. Installation and commissioning should be carried out by suitably qualified three‑phase installers or via Energian’s trusted partners to ensure compliance with G99 and other local requirements.\u003c\/p\u003e\n\u003c!-- D. KEY FEATURES --\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eParallel operation: supports up to 10 parallel systems, covering power requirements from 49.9kW to 600kW.\u003c\/li\u003e\n\u003cli\u003eBattery options and high‑voltage LFP battery input (180–820V) with up to 160A charge\/discharge current (80A × 2).\u003c\/li\u003e\n\u003cli\u003ePV oversizing up to 200%, with up to 5 or 6 MPPTs (model‑dependent) and 2 strings per MPPT for array flexibility.\u003c\/li\u003e\n\u003cli\u003e100% three‑phase unbalance support, 110% long‑term overload and 150% off‑grid overload capability.\u003c\/li\u003e\n\u003cli\u003eRemote monitoring via web\/app, OTA updates, versatile operating modes (self‑consumption, peak‑shaving, demand management) and VPP integration via IEEE2030.5 and OpenADR (where available).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- E. TECHNICAL SPECIFICATIONS – DIRECTLY FROM DATASHEET --\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003cp\u003eValues below are taken from the X3‑AELIO datasheet for models X3‑AELIO‑49.9K \/ 49.9K‑P \/ 50K \/ 60K \/ 61K; select the 60kW column (X3‑AELIO‑60K) for this product and always confirm against the latest SolaX documentation.\u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" cellspacing=\"0\" cellpadding=\"6\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; width: 100.043%;\" colspan=\"2\"\u003eModels covered\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eModel range\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e X3‑AELIO‑60K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; width: 100.043%;\" colspan=\"2\"\u003ePV input\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eMax. recommended PV array power\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e120 kWp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eMax. PV input voltage①\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eRated PV input voltage\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e650 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eMPPT voltage range②\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e160 ~ 950 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eStart‑up voltage\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e180 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eNo. of MPP trackers \/ strings per MPP tracker\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e5 \/ 2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eMax. input current per MPPT\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eMax. input short circuit current per MPPT\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; width: 100.043%;\" colspan=\"2\"\u003eAC input \u0026amp; output (on‑grid)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eRated output power\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e60.0 kW \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eRated output current\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e90.1 A @ 220 V 87.0 A @ 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eMax. output apparent power\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e66.0 kVA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eMax. output continuous current\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e100.0 A @ 220 V 95.7 A @ 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eRated AC voltage\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e3 \/ N \/ PE, 220 \/ 380 V; 3 \/ N \/ PE, 230 \/ 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eRated AC frequency\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e50 Hz \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eAC frequency range③\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e50 ± 5 Hz \/ 60 ± 5 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eAdjustable power factor range\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e~ 1 (0.8 lagging to 0.8 leading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eTHDi (rated power)\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e\u0026lt; 3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; width: 100.043%;\" colspan=\"2\"\u003eBattery\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eBattery type\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003eLFP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eBattery voltage range\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e180 ~ 820 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eMax. charge \/ discharge current\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e160 A (80 A × 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; width: 100.043%;\" colspan=\"2\"\u003eEPS (off‑grid) output\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eRated EPS output voltage, frequency\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e3 \/ N \/ PE, 220 \/ 380 V, 50 Hz \/ 60 Hz; 3 \/ N \/ PE, 230 \/ 400 V, 50 Hz \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eRated EPS output power\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e60.0 kVA A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eMax EPS output power\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e90 kVA, 10 s \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eSwitchover time\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e\u0026lt; 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; width: 100.043%;\" colspan=\"2\"\u003eEfficiency\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eMax. efficiency\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e98.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eEuropean efficiency\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e97.2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; width: 100.043%;\" colspan=\"2\"\u003eEnvironment limit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eIngress protection\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eOperating temperature range\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e‑35 ~ 60°C (derating +45℃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eMax. operating altitude\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eRelative humidity\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e0 ~ 100% RH (condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003eMains: Ⅲ, Battery: Ⅱ, PV: Ⅱ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; width: 100.043%;\" colspan=\"2\"\u003eGeneral\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e670 × 820 × 257 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eNet weight\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003e\u0026lt; 100 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eCooling concept\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003eSmart air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eCommunication interfaces\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003eRS485‑Meter, RS485‑Monitor, RS485‑Parallel (daisy‑chain), CAN‑BMS, CAN‑Parallel (daisy‑chain), USB, DI×2, DO×1, RCR(DI×4), DRM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eTopology\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003eNon‑isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eCertificates and approvals\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003eCE, VDE4105, G99, AS4777, EN50549, CEI 0‑21, IEC61727, PEA\/MEA, NRS‑097‑2‑1, RD1699, TOR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; width: 100.043%;\" colspan=\"2\"\u003eProtection functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eOver \/ under voltage protection\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eDC isolation protection\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eDC reverse‑polarity protection\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eGrid monitoring\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eDC injection monitoring\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eBack feed current monitoring\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eResidual current detection\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eOver temperature protection\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eActive anti‑islanding method\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003eFrequency shift\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eSurge protection (DC \/ AC)\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003eDC: Type Ⅱ, AC: Type Ⅱ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eArc‑fault circuit interrupter (AFCI)\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eAC auxiliary power supply (APS)\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003eBuilt‑in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; width: 100.043%;\" colspan=\"2\"\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eNote ①\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003eThe maximum input voltage is the upper limit of the DC voltage. Any higher input DC voltage would probably damage inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eNote ②\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003eInput voltage exceeding the MPPT voltage range may trigger inverter protection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 53.6385%;\"\u003eNote ③\u003c\/td\u003e\n\u003ctd style=\"width: 46.4049%;\"\u003eThe AC frequency range may vary from different country codes.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- DOCUMENTS SECTION --\u003e\n\u003ch2\u003eDocuments available for download\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\n\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/AELIO_Datasheet.pdf?v=1781613445\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" target=\"_blank\"\u003eSolaX X3‑AELIO 49.9–61kW datasheet (including X3‑AELIO‑60)\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- SHIPPING \u0026 SUPPORT --\u003e\n\u003ch2\u003eShipping and UK expert support\u003c\/h2\u003e\n\u003cp\u003eShipping is available to the UK, Ireland, Africa, the Caribbean and worldwide. If a shipping rate is not shown at checkout, please contact us on +44 2080640335 or \u003ca href=\"mailto:info@energian.co.uk\"\u003einfo@energian.co.uk\u003c\/a\u003e for a quote.\u003c\/p\u003e\n\u003cp\u003eUK‑based expert support is available via phone, email and live chat for product selection, system design checks, communications setup and commissioning guidance. For the SolaX X3‑AELIO 60kW HV Commercial 3‑Phase Hybrid Inverter we recommend installation and sign‑off by qualified three‑phase installers or our trusted partners to ensure safe operation and compliance with local grid regulations.\u003c\/p\u003e\n\u003cp\u003eYou are welcome to visit our Croydon office for an in‑person consultation to review your PV layout, battery configuration, generator integration and control strategy before finalising your order.\u003c\/p\u003e\n\u003c!-- META + ALT (HIDDEN FOR THEME USE) --\u003e\n\u003cdiv style=\"display: none;\"\u003e\n\u003cspan class=\"meta-description\"\u003e SolaX X3‑AELIO 50kW HV Commercial 3‑Phase Hybrid Inverter with high‑voltage LFP battery support, up to 200% PV oversizing, IP66 rating and UK‑based expert support with worldwide shipping. \u003c\/span\u003e \u003cimg alt=\"SolaX X3-AELIO 50kW HV commercial three phase hybrid inverter front view\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SolaX","offers":[{"title":"Default Title","offer_id":57556949926270,"sku":"X3-AELIO-60K","price":5400.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/AELIOinverter.jpg?v=1781613731","url":"https:\/\/www.energian.co.uk\/products\/solax-x3-aelio-60kw-hv-commercial-3-phase-hybrid-inverter","provider":"Energian","version":"1.0","type":"link"}