{"product_id":"solaredge-c-i-energy-storage-system-with-50-kw-ac-coupled-inverter-and-197-kwh-battery-copy","title":"SolarEdge C\u0026I Energy Storage System With 50 kW AC Coupled Inverter and 197 kWh Battery","description":"\u003cdiv style=\"font-family: Helvetica,Arial,sans-serif; color: #333; line-height: 1.65; font-size: 18px; max-width: 1000px; margin: 0 auto;\"\u003e\n\u003ch1 style=\"font-size: 32px; line-height: 1.25; text-align: center;\"\u003e\u003cstrong\u003eSolarEdge C\u0026amp;I Energy Storage System with 50kW AC-Coupled Inverter and 197kWh Battery\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cul style=\"font-size: 18px; padding-left: 24px;\"\u003e\n\u003cli\u003eStore surplus solar energy and manage site electricity demand with 50kW of rated AC output and 197kWh of battery capacity.\u003c\/li\u003e\n\u003cli\u003eSupport self-consumption, peak shaving and tariff optimisation through SolarEdge ONE for C\u0026amp;I, subject to regional availability and site configuration.\u003c\/li\u003e\n\u003cli\u003ePre-assembled LFP battery cabinet with built-in HVAC, layered safety systems and a 10-year product and performance warranty, subject to manufacturer terms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eSolarEdge 50kW commercial battery storage system\u003c\/h2\u003e\n\u003cp\u003eThe SolarEdge CSS-OD 197 combines one CSS-OU-197 battery cabinet with one PCS050 50kW AC-coupled battery inverter for grid-connected commercial and industrial sites. The cabinet provides 197.12kWh total storage and 187.15kWh usable capacity. It is designed to work alongside an AC-coupled SolarEdge PV system, with SolarEdge ONE for C\u0026amp;I managing site generation, storage and consumption.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eKey features\u003c\/h2\u003e\n\u003cul style=\"padding-left: 24px;\"\u003e\n\u003cli\u003eMore control over site energy: supported operating modes include maximised self-consumption, peak shaving, tariff optimisation and import\/export limits. Feature availability and financial results depend on the region, tariffs and installation.\u003c\/li\u003e\n\u003cli\u003e50kW three-phase battery inverter: PCS050 provides 50kW rated active output, up to 55kVA apparent output and a maximum inverter efficiency of 97.5%.\u003c\/li\u003e\n\u003cli\u003ePre-assembled storage cabinet: factory-tested construction, lifting eye bolts and SolarEdge Go commissioning tools support installation and deployment.\u003c\/li\u003e\n\u003cli\u003eIntegrated thermal management and protection: built-in HVAC, smoke and environmental sensing, emergency power-off and fire-suppression provisions form part of the cabinet’s layered protection system.\u003c\/li\u003e\n\u003cli\u003eExpandable architecture: the cabinet supports one or two PCS050 inverters, with larger site configurations available through project-specific design. This listing includes one 50kW inverter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eWhere to use\u003c\/h2\u003e\n\u003cp\u003eConsider this SolarEdge C\u0026amp;I energy storage system for warehouses, logistics facilities, factories, retail premises, agricultural businesses and other grid-connected sites with compatible SolarEdge PV. Suitable applications include storing daytime surplus generation for later use and managing demand peaks within the available inverter and battery limits.\u003c\/p\u003e\n\u003cp\u003eThe supplied datasheet requires an AC-coupled SolarEdge PV system at the site. Do not assume compatibility with a third-party-only PV installation, stand-alone operation or generator-only charging without written manufacturer approval.\u003c\/p\u003e\n\u003cp\u003eThis listing does not include a verified islanding or backup-power configuration and must not be treated as a zero-transfer-time UPS. The battery inverter must not be used to connect life-support or medical equipment directly.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eSystem contents and project requirements\u003c\/h2\u003e\n\u003cul style=\"padding-left: 24px;\"\u003e\n\u003cli\u003e1 × SolarEdge CSS-OU-197 battery cabinet with 11 battery modules.\u003c\/li\u003e\n\u003cli\u003e1 × SolarEdge PCS050 50kW AC-coupled battery inverter.\u003c\/li\u003e\n\u003cli\u003eSolarEdge ONE controller, metering, communication equipment, interconnection cables, switchgear, protection, foundations and installation are subject to the agreed project BOM; inclusion is not assumed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis is an engineered commercial installation, not an out-of-the-box appliance. The cabinet weighs 2,360kg and requires a suitable foundation, access for lifting equipment, manufacturer-specified clearances and a separate single-phase auxiliary supply for HVAC operation.\u003c\/p\u003e\n\u003cp\u003eEnergian can assist with site-load assessment, system sizing, SolarEdge compatibility, grid-connection requirements and installation through trusted partners. Confirm the applicable UK grid-connection evidence and obtain the required DNO approvals before installation.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eTechnical specifications\u003c\/h2\u003e\n\u003cp\u003eSpecifications follow the supplied SolarEdge CSS-OD 197 datasheet, DS-000233-ENG, dated 18 October 2026. Battery-cabinet and inverter ratings are kept separate. Larger-system figures describe expansion capability, not equipment included in this package.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 17px; text-align: left;\" border=\"1\" cellpadding=\"10\"\u003e\n\u003cthead style=\"background: #f2f3f5;\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width: 55%;\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f2f3f5; text-align: left;\"\u003ePackage identification and configuration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSolarEdge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem family\u003c\/td\u003e\n\u003ctd\u003eCSS-OD 197\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery cabinet\u003c\/td\u003e\n\u003ctd\u003eCSS-OU-197\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery inverter\u003c\/td\u003e\n\u003ctd\u003ePCS050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet quantity in this package\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter quantity in this package\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated AC active output\u003c\/td\u003e\n\u003ctd\u003e50kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery total capacity\u003c\/td\u003e\n\u003ctd\u003e197.12kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery usable capacity\u003c\/td\u003e\n\u003ctd\u003e187.15kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eOn-grid commercial and industrial energy storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoupling\u003c\/td\u003e\n\u003ctd\u003eAC-coupled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV prerequisite\u003c\/td\u003e\n\u003ctd\u003eAn AC-coupled SolarEdge PV system is required at the site.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy management\u003c\/td\u003e\n\u003ctd\u003eSolarEdge ONE for C\u0026amp;I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommissioning platform\u003c\/td\u003e\n\u003ctd\u003eSolarEdge Go\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f2f3f5; text-align: left;\"\u003eBattery cabinet: electrical specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell chemistry\u003c\/td\u003e\n\u003ctd\u003eLFP \/ lithium iron phosphate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal cabinet capacity\u003c\/td\u003e\n\u003ctd\u003e197.12kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsable cabinet capacity\u003c\/td\u003e\n\u003ctd\u003e187.15kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery-module total capacity\u003c\/td\u003e\n\u003ctd\u003e17.92kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of battery modules\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum charge\/discharge C-rate\u003c\/td\u003e\n\u003ctd\u003e0.5C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery DC voltage range\u003c\/td\u003e\n\u003ctd\u003e627–792V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary AC input at 50Hz\u003c\/td\u003e\n\u003ctd\u003e220V AC ±15%, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary AC input at 60Hz\u003c\/td\u003e\n\u003ctd\u003e220V AC ±10%, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary-supply requirement\u003c\/td\u003e\n\u003ctd\u003eSingle-phase power required for battery-cabinet HVAC operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f2f3f5; text-align: left;\"\u003eBattery cabinet: mechanical and environmental specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet dimensions, W × D × H\u003c\/td\u003e\n\u003ctd\u003e1,300 × 1,200 × 2,360mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet weight\u003c\/td\u003e\n\u003ctd\u003e2,360kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress protection\u003c\/td\u003e\n\u003ctd\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion protection\u003c\/td\u003e\n\u003ctd\u003eC4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling method\u003c\/td\u003e\n\u003ctd\u003eBuilt-in HVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation location\u003c\/td\u003e\n\u003ctd\u003eIndoor or outdoor, subject to manufacturer siting and installation requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePublished noise level\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;70dBA, measured 1m from a CSS-OD cabinet with one battery inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−30°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-temperature derating\u003c\/td\u003e\n\u003ctd\u003eAbove 45°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow-temperature derating\u003c\/td\u003e\n\u003ctd\u003eMay also apply between −30°C and −10°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e5–95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating altitude\u003c\/td\u003e\n\u003ctd\u003e3,000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f2f3f5; text-align: left;\"\u003eBattery cabinet: safety systems\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection architecture\u003c\/td\u003e\n\u003ctd\u003eLayered protection at cell, module, cluster and cabinet levels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat and humidity detection\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmoke detection\u003c\/td\u003e\n\u003ctd\u003ePhotoelectric smoke detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet-level fire-suppression provision\u003c\/td\u003e\n\u003ctd\u003e2 × aerosol units; support for an external water pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule-level fire-suppression provision\u003c\/td\u003e\n\u003ctd\u003eEnergy modules integrated with NOVEC 1230, as stated in the supplied datasheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire-safety qualification\u003c\/td\u003e\n\u003ctd\u003eIntegrated detection and suppression do not replace the site fire-risk assessment, emergency plan or manufacturer installation requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReverse-polarity protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth-fault and leakage-fault detection\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge protection\u003c\/td\u003e\n\u003ctd\u003eAC and DC protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperator-safety sensor\u003c\/td\u003e\n\u003ctd\u003eCO toxic-gas detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency power-off pushbutton\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlood detector\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDoor contact switch\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-relief valves and deflagration panels\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f2f3f5; text-align: left;\"\u003eBattery cabinet: standards and handling\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety references listed\u003c\/td\u003e\n\u003ctd\u003eIEC 62619; UL 9540A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL 9540A qualification\u003c\/td\u003e\n\u003ctd\u003eA thermal-runaway fire-propagation test-method reference; it must not be presented as a guarantee that fire cannot occur.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress-protection standard\u003c\/td\u003e\n\u003ctd\u003eIEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransportation reference\u003c\/td\u003e\n\u003ctd\u003eUN 38.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC references\u003c\/td\u003e\n\u003ctd\u003eEN \/ IEC 61000-6-2; EN \/ IEC 61000-6-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForklift handling\u003c\/td\u003e\n\u003ctd\u003eIntegrated fork supports; datasheet specifies forklift capacity greater than 5,000kg. Follow the manufacturer’s lifting procedure and load-centre requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrane handling\u003c\/td\u003e\n\u003ctd\u003eFour lifting eye bolts supplied; approved lifting equipment and procedure required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f2f3f5; text-align: left;\"\u003ePCS050 inverter: AC specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated AC active output power\u003c\/td\u003e\n\u003ctd\u003e50kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum AC apparent output power\u003c\/td\u003e\n\u003ctd\u003e55kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum continuous output current\u003c\/td\u003e\n\u003ctd\u003e80A per phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum inverter efficiency\u003c\/td\u003e\n\u003ctd\u003e97.5%; this is not the complete system’s round-trip efficiency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC output voltage\u003c\/td\u003e\n\u003ctd\u003e400V line-to-line \/ 230V line-to-neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC voltage range stated in datasheet\u003c\/td\u003e\n\u003ctd\u003e340–440V AC; confirm the applicable wiring and voltage limits in the installation documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60Hz ±5Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC wiring\u003c\/td\u003e\n\u003ctd\u003e3W + PE \/ 4W + PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid configurations\u003c\/td\u003e\n\u003ctd\u003eDelta or Wye\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall response time\u003c\/td\u003e\n\u003ctd\u003e≤ approximately 1.2–1.5 seconds, as stated in the datasheet; this is not a UPS transfer-time specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal harmonic distortion\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower-factor range\u003c\/td\u003e\n\u003ctd\u003e−1 to +1; leading or lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermitted inverter quantity per cabinet\u003c\/td\u003e\n\u003ctd\u003e1 or 2 PCS050 inverters; this package includes 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f2f3f5; text-align: left;\"\u003ePCS050 inverter: DC specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum DC input power\u003c\/td\u003e\n\u003ctd\u003e55kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum DC current\u003c\/td\u003e\n\u003ctd\u003e55A × 2 interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of DC input interfaces\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f2f3f5; text-align: left;\"\u003ePCS050 inverter: protection and communication\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReverse-polarity protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth-fault protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth-leakage protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC surge protection\u003c\/td\u003e\n\u003ctd\u003eType II integrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC surge protection\u003c\/td\u003e\n\u003ctd\u003eType III integrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication ports\u003c\/td\u003e\n\u003ctd\u003eRS485 \/ CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f2f3f5; text-align: left;\"\u003ePCS050 inverter: mechanical and environmental specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions, W × D × H\u003c\/td\u003e\n\u003ctd\u003e650 × 324 × 715mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e68kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress protection\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eAir cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC cable cross-section\u003c\/td\u003e\n\u003ctd\u003e25–35mm²; final selection subject to installation design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC cable lug size\u003c\/td\u003e\n\u003ctd\u003eM6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor material\u003c\/td\u003e\n\u003ctd\u003eCopper only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended conductor construction\u003c\/td\u003e\n\u003ctd\u003eFlexible, multi-stranded class 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20°C to +60°C; derating above 45°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e5–95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating altitude\u003c\/td\u003e\n\u003ctd\u003e3,000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f2f3f5; text-align: left;\"\u003ePCS050 inverter: standards and grid connection\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety references\u003c\/td\u003e\n\u003ctd\u003eIEC 62109-1; IEC 62109-2; IEC 62477-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmissions references reproduced from datasheet\u003c\/td\u003e\n\u003ctd\u003eIEC 61000-6-4; IEC 61000-3-11; EN\/IEC 61000-3; CISPR 11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid-connection references listed\u003c\/td\u003e\n\u003ctd\u003eNRS 097-2-1:2017 Edition 2.1; NRS 097-2-1:2024 Edition 3; CEI-016; CEI 0-21; VDE AR-N-4105; VDE AR-N 4110; EN 50549-1\/10; RfG; NC RfG; PTPiREE; UNE 217002; NTS V2.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid-strength qualification\u003c\/td\u003e\n\u003ctd\u003eThe datasheet’s VDE AR-N 4110 note specifies a minimum short-circuit ratio of 10 at the point of common coupling.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUK grid-connection approval\u003c\/td\u003e\n\u003ctd\u003eConfirm model-specific UK connection evidence, protection requirements and DNO approval for the proposed installation. The supplied standards list does not itself establish G99 approval.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedical\/life-support restriction\u003c\/td\u003e\n\u003ctd\u003eThe battery inverter must not be used to connect life-support or medical equipment directly.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f2f3f5; text-align: left;\"\u003eExpansion and energy management\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional second inverter\u003c\/td\u003e\n\u003ctd\u003eA second PCS050 may be specified separately, subject to approved design and commissioning.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTwo-inverter cabinet power limitation\u003c\/td\u003e\n\u003ctd\u003eThe datasheet limits maximum power to 98.5kW when paired with this battery cabinet; do not assume unrestricted 100kW operation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePublished larger-site configuration\u003c\/td\u003e\n\u003ctd\u003eUp to 1MW \/ 2MWh at 0.5C, or up to 1MW \/ 4MWh at 0.25C; project-specific design required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListed optimisation modes\u003c\/td\u003e\n\u003ctd\u003eMaximised self-consumption; peak shaving; tariff optimisation; export and import limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimisation qualification\u003c\/td\u003e\n\u003ctd\u003eSome features may not be available in every region. Savings depend on tariffs, site operation and installation conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f2f3f5; text-align: left;\"\u003eWarranty\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery system warranty\u003c\/td\u003e\n\u003ctd\u003e10 years, subject to the SolarEdge CSS-OD limited warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery performance statement\u003c\/td\u003e\n\u003ctd\u003e8,000 cycles or 10 years, up to 70% state of health, as stated in the datasheet; applicable definitions, limits and exclusions are governed by the warranty document\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCS050 inverter warranty\u003c\/td\u003e\n\u003ctd\u003e10 years, subject to the SolarEdge CSS-OD limited warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty qualification\u003c\/td\u003e\n\u003ctd\u003eInstallation, commissioning, operation, maintenance, transport and storage must comply with SolarEdge’s requirements and applicable regulations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eDocuments available for download\u003c\/h2\u003e\n\u003cul style=\"padding-left: 24px;\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/knowledge-center.solaredge.com\/sites\/kc\/files\/se-css-od_197kwh-battery-cabinet-and-battery-inverter-datasheet-eng.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSolarEdge CSS-OD 197 battery cabinet and PCS050 inverter datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/knowledge-center.solaredge.com\/sites\/kc\/files\/se-solaredge-css-on-grid_197kwh-quick-installation-guide-eu.pdf\" rel=\"noopener\" target=\"_blank\"\u003eSolarEdge CSS-OD 197 quick installation guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- Before publication: confirm the exact regional ordering codes, included controller\/meter\/cable scope, UK grid-connection evidence, product availability and applicable warranty revision. Use the supplied 18 October 2026 datasheet where online revisions differ. --\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eShipping\u003c\/h2\u003e\n\u003cp\u003eShipping is available to the UK, Ireland, Africa, the Caribbean and worldwide, subject to destination and transport requirements. If a shipping rate is not shown at checkout, contact us on \u003ca href=\"tel:+442080640335\"\u003e+44 20 8064 0335\u003c\/a\u003e or \u003ca href=\"mailto:info@energian.co.uk\"\u003einfo@energian.co.uk\u003c\/a\u003e for a quote.\u003c\/p\u003e\n\u003cp\u003eDelivery access, unloading and lifting arrangements must be agreed before dispatch. The battery cabinet requires specialist handling; standard parcel delivery is not applicable.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eUK expert support\u003c\/h2\u003e\n\u003cp\u003eEnergian’s UK team can help assess site demand, PV compatibility, storage sizing, grid-connection requirements and installation options. Contact us by phone, email or live chat with questions or support requests, or arrange an in-person consultation at our office. Installation can be arranged through trusted partners.\u003c\/p\u003e\n\u003c!-- Shopify SEO title: SolarEdge 50kW 197kWh C\u0026I Energy Storage | Energian --\u003e \u003c!-- Shopify meta description: SolarEdge C\u0026I energy storage with a 50kW AC-coupled inverter and 197.12kWh LFP battery, 187.15kWh usable. For compatible on-grid SolarEdge PV sites. --\u003e \u003c!-- Suggested alt text for an actual package image: SolarEdge CSS-OD 197 commercial energy storage system with CSS-OU-197 battery cabinet and one PCS050 50kW AC-coupled inverter. --\u003e\n\u003c\/div\u003e","brand":"SolarEdge","offers":[{"title":"Default Title","offer_id":58340489724286,"sku":"SE-CSS-OU-O1-11-CA-197-01","price":46592.59,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/SE-CSS-OU-O1-11-CA-197-01.jpg?v=1793191995","url":"https:\/\/www.energian.co.uk\/products\/solaredge-c-i-energy-storage-system-with-50-kw-ac-coupled-inverter-and-197-kwh-battery-copy","provider":"Energian","version":"1.0","type":"link"}