{"product_id":"solaredge-430w-mono-half-cut-topcon-solar-panel-with-built-in-optimiser","title":"SolarEdge 430W Mono Half Cut TOPCon Solar Panel with Built in Optimiser","description":"\u003cdiv style=\"font-family: Helvetica, Arial, sans-serif; color: #333; line-height: 1.6; max-width: 1000px; margin: 0 auto; font-size: 18px;\"\u003e\n\u003c!-- SEO title: SolarEdge 430W TOPCon Solar Panel with Built-in Optimiser | Energian --\u003e \u003c!-- Meta description: SolarEdge 430W TOPCon solar panel with built-in S440 optimiser, bifacial double glass and module-level monitoring. UK expert support from Energian. --\u003e \u003c!-- Product image alt text: SolarEdge 430W mono half-cut TOPCon solar panel with built-in S440 optimiser SPV430-R54PDTL --\u003e\n\u003ch1 style=\"font-size: 32px; line-height: 1.3; text-align: center;\"\u003e\u003cstrong\u003eSolarEdge 430W Mono Half-Cut TOPCon Solar Panel with Built-in Optimiser\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cul style=\"font-size: 18px;\"\u003e\n\u003cli\u003e430 W solar panel with an integrated S440 optimiser that tracks each module’s maximum power point individually.\u003c\/li\u003e\n\u003cli\u003eBifacial double-glass construction with a black anodised aluminium frame for commercial, industrial and residential solar PV arrays.\u003c\/li\u003e\n\u003cli\u003eModule-level monitoring, SafeDC voltage shutdown, a 25-year product warranty and a 30-year linear performance warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 26px; line-height: 1.3;\"\u003eSolarEdge 430W TOPCon solar panel with built-in optimiser\u003c\/h2\u003e\n\u003cp\u003eThe SolarEdge 430W Mono Half-Cut TOPCon Solar Panel with Built-in Optimiser combines a bifacial N-type module with a pre-assembled S440 power optimiser. The SPV430-R54PDTL provides 22.02% module efficiency under standard test conditions, individual module optimisation and performance monitoring as part of a compatible SolarEdge system.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 26px; line-height: 1.3;\"\u003eKey features\u003c\/h2\u003e\n\u003cul style=\"font-size: 18px;\"\u003e\n\u003cli\u003eIndividual module optimisation: the integrated S440 optimiser tracks each panel’s maximum power point rather than relying solely on string-level tracking.\u003c\/li\u003e\n\u003cli\u003ePre-assembled optimiser: simplifies installation and cable management, with MC4 input and output connections.\u003c\/li\u003e\n\u003cli\u003eBifacial double-glass module: 108 monocrystalline half-cut cells with 1.6 mm tempered glass on both sides; rear-side generation depends on the installation layout and reflected light.\u003c\/li\u003e\n\u003cli\u003eMonitoring and safety functions: SolarEdge module-level monitoring and SafeDC voltage shutdown. Sense Connect is designed to detect and help prevent potential connector-level electrical arcs, subject to inverter model and firmware version.\u003c\/li\u003e\n\u003cli\u003eManufacturer warranties: 25 years for the module and optimiser, plus a 30-year linear performance warranty specifying 99% output in year one and 89.4% at year 30, subject to warranty terms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 26px; line-height: 1.3;\"\u003eWhere to use\u003c\/h2\u003e\n\u003cp\u003eSuitable applications include warehouses, logistics facilities, commercial and industrial rooftops, agricultural buildings and residential solar PV systems designed around compatible SolarEdge inverters.\u003c\/p\u003e\n\u003cp\u003eThis panel is a system component, not a stand-alone power supply. The inverter model, optimiser string length, connected power, DC protection and monitoring configuration must be checked as part of the complete system design.\u003c\/p\u003e\n\u003cp\u003eUse mounting hardware suitable for the 30 mm frame and the approved attachment zones. Mechanical load limits vary with the mounting arrangement, and bifacial output depends on mounting height, shading, spacing and the reflectivity of the surface below the panels.\u003c\/p\u003e\n\u003cp\u003eEnergian can help with module quantities, SolarEdge compatibility, mounting selection and inverter string design. Where the complete system cannot be used out of the box, installation can be arranged through trusted partners.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 26px; line-height: 1.3;\"\u003eTechnical specifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 16px; text-align: left;\" border=\"1\" cellpadding=\"8\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f3f3f3; text-align: left;\"\u003eModule identification and electrical properties\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 55%;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSolarEdge Technologies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule model\u003c\/td\u003e\n\u003ctd\u003eSPV430-R54PDTL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDatasheet series\u003c\/td\u003e\n\u003ctd\u003eSPV425-R54PDTL \/ SPV430-R54PDTL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell technology\u003c\/td\u003e\n\u003ctd\u003eN-type TOPCon, monocrystalline half-cut cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule construction\u003c\/td\u003e\n\u003ctd\u003eBifacial, dual glass, integrated power optimiser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated optimiser model\u003c\/td\u003e\n\u003ctd\u003eS440\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated module power at STC\u003c\/td\u003e\n\u003ctd\u003e430 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule efficiency at STC\u003c\/td\u003e\n\u003ctd\u003e22.02%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum power voltage (Vmp)\u003c\/td\u003e\n\u003ctd\u003e32.34 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum power current (Imp)\u003c\/td\u003e\n\u003ctd\u003e13.30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-circuit voltage (Voc)\u003c\/td\u003e\n\u003ctd\u003e39.03 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current (Isc)\u003c\/td\u003e\n\u003ctd\u003e13.95 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum system voltage\u003c\/td\u003e\n\u003ctd\u003e1000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum series fuse rating\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard test conditions (STC)\u003c\/td\u003e\n\u003ctd\u003eIrradiance 1000 W\/m²; cell temperature 25°C; air mass AM1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower bifaciality\u003c\/td\u003e\n\u003ctd\u003e80 ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f3f3f3; text-align: left;\"\u003eModule mechanical properties\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of cells\u003c\/td\u003e\n\u003ctd\u003e108 (6 × 18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell type\u003c\/td\u003e\n\u003ctd\u003eMonocrystalline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell dimensions\u003c\/td\u003e\n\u003ctd\u003e182 × 91 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule dimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e1722 × 1134 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule weight, including power optimiser\u003c\/td\u003e\n\u003ctd\u003e21.74 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront \/ rear glass\u003c\/td\u003e\n\u003ctd\u003e1.6 mm \/ 1.6 mm, dual-layer tempered glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame\u003c\/td\u003e\n\u003ctd\u003eBlack anodised aluminium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction box\u003c\/td\u003e\n\u003ctd\u003eIP68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector type\u003c\/td\u003e\n\u003ctd\u003eMC4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront-side maximum load (snow)\u003c\/td\u003e\n\u003ctd\u003e5400 Pa, subject to the approved mounting arrangement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear-side maximum load (wind)\u003c\/td\u003e\n\u003ctd\u003e2400 Pa, subject to the approved mounting arrangement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f3f3f3; text-align: left;\"\u003eModule temperature coefficients\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower temperature coefficient (Pm)\u003c\/td\u003e\n\u003ctd\u003e−0.30%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage temperature coefficient (Voc)\u003c\/td\u003e\n\u003ctd\u003e−0.25%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent temperature coefficient (Isc)\u003c\/td\u003e\n\u003ctd\u003e+0.045%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f3f3f3; text-align: left;\"\u003eModule certifications and warranties\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61215:2016; IEC 61730:2016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia test\u003c\/td\u003e\n\u003ctd\u003eIEC 62716:2013\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalt mist test\u003c\/td\u003e\n\u003ctd\u003eIEC 61701:2016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePID testing method\u003c\/td\u003e\n\u003ctd\u003eIEC TS 62804-1:2015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHail test\u003c\/td\u003e\n\u003ctd\u003e35 mm hail test according to IEC 61215-2:2016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule product warranty\u003c\/td\u003e\n\u003ctd\u003e25 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower optimiser product warranty\u003c\/td\u003e\n\u003ctd\u003e25 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule linear performance warranty\u003c\/td\u003e\n\u003ctd\u003e30 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranted power output\u003c\/td\u003e\n\u003ctd\u003e99% in year one; 89.4% at year 30, subject to manufacturer warranty terms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f3f3f3; text-align: left;\"\u003eS440 optimiser input specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input DC power\u003c\/td\u003e\n\u003ctd\u003e440 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute maximum input voltage (Voc)\u003c\/td\u003e\n\u003ctd\u003e60 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT operating range\u003c\/td\u003e\n\u003ctd\u003e8–60 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum short-circuit current of connected PV module\u003c\/td\u003e\n\u003ctd\u003e14.5 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum efficiency\u003c\/td\u003e\n\u003ctd\u003e99.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeighted efficiency\u003c\/td\u003e\n\u003ctd\u003e98.6%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule input power condition\u003c\/td\u003e\n\u003ctd\u003eModule rated power at STC must not exceed the optimiser’s rated input DC power; modules with up to +5% power tolerance are allowed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f3f3f3; text-align: left;\"\u003eS440 optimiser output specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum output current during operation\u003c\/td\u003e\n\u003ctd\u003e15 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum output voltage during operation\u003c\/td\u003e\n\u003ctd\u003e60 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety output voltage per optimiser\u003c\/td\u003e\n\u003ctd\u003e1 ±0.1 V DC when disconnected from the inverter or when the inverter is off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f3f3f3; text-align: left;\"\u003eS440 optimiser compliance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eFCC Part 15 Class B; IEC 61000-6-2; IEC 61000-6-3; CISPR 11; EN 55011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eIEC 62109-1, Class II safety; UL 1741\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eUL 94 V-0; UV resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire safety standard\u003c\/td\u003e\n\u003ctd\u003eVDE-AR-E 2100-712:2018-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE compliance documentation\u003c\/td\u003e\n\u003ctd\u003eRefer to the manufacturer’s Declaration of Conformity — CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f3f3f3; text-align: left;\"\u003eS440 optimiser installation specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum allowed system voltage\u003c\/td\u003e\n\u003ctd\u003e1000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimiser dimensions (W × L × H)\u003c\/td\u003e\n\u003ctd\u003e129 × 155 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimiser weight, including cables\u003c\/td\u003e\n\u003ctd\u003e740 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput connector\u003c\/td\u003e\n\u003ctd\u003eMC4; contact SolarEdge for other connector types\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput wire length\u003c\/td\u003e\n\u003ctd\u003e0.1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput connector\u003c\/td\u003e\n\u003ctd\u003eMC4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput wire length\u003c\/td\u003e\n\u003ctd\u003ePositive: 2.3 m; negative: 0.10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature range\u003c\/td\u003e\n\u003ctd\u003e−40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature derating note\u003c\/td\u003e\n\u003ctd\u003eThe datasheet states that power derating applies above +85°C ambient; refer to the Power Optimisers Temperature Derating technical note\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e0–100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"background: #f3f3f3; text-align: left;\"\u003eMounting and installation requirements — R54PDTL series\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation personnel\u003c\/td\u003e\n\u003ctd\u003eAuthorised and qualified personnel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum installation altitude\u003c\/td\u003e\n\u003ctd\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum distance from shoreline or saline environment\u003c\/td\u003e\n\u003ctd\u003e50 m, with no direct saltwater contact, splashes or spray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-side clamping zone\u003c\/td\u003e\n\u003ctd\u003e380–480 mm from the short edge; follow the manual’s mounting diagrams and permitted positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-side clamping load thresholds\u003c\/td\u003e\n\u003ctd\u003eFront: 5400 Pa; rear: 2400 Pa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-side clamping zone\u003c\/td\u003e\n\u003ctd\u003e0–100 mm, as defined in the installation manual’s diagrams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-side clamping load thresholds\u003c\/td\u003e\n\u003ctd\u003eFront: 2000 Pa; rear: 1600 Pa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum clamps per module\u003c\/td\u003e\n\u003ctd\u003e4, positioned symmetrically\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum recommended clamp length\u003c\/td\u003e\n\u003ctd\u003e60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClamp material\u003c\/td\u003e\n\u003ctd\u003eAnodised aluminium alloy or stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClamp fixing screw torque\u003c\/td\u003e\n\u003ctd\u003e16–20 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScrew mounting method\u003c\/td\u003e\n\u003ctd\u003eUse all 8 existing mounting holes with corrosion-resistant M8 screws, spring washers and flat washers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting screw torque\u003c\/td\u003e\n\u003ctd\u003e16–20 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame modification\u003c\/td\u003e\n\u003ctd\u003eDo not modify the frame or drill additional holes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField cable cross-section specified in manual\u003c\/td\u003e\n\u003ctd\u003e4 mm² (12 AWG), suitable for the maximum possible system open-circuit voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum cable bending radius\u003c\/td\u003e\n\u003ctd\u003e43 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame grounding hole diameter\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding hardware\u003c\/td\u003e\n\u003ctd\u003eM5 stainless-steel bolt, nut and gasket, with ground wire and fastening bolt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding fastener torque\u003c\/td\u003e\n\u003ctd\u003e2.1 ±0.1 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding material restriction\u003c\/td\u003e\n\u003ctd\u003eDo not attach copper wire directly to aluminium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical monitoring layout\u003c\/td\u003e\n\u003ctd\u003eMap installed module or optimiser locations to display their physical positions in the monitoring platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDatasheet reference\u003c\/td\u003e\n\u003ctd\u003eDS-000226-ROW; 14 May 2024; specifications subject to change\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"font-size: 22px;\"\u003eSolarEdge inverter string-design limits\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 16px; text-align: left;\" border=\"1\" cellpadding=\"8\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f3f3f3;\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eHome Wave single phase\u003c\/th\u003e\n\u003cth\u003eHome Short String three phase\u003c\/th\u003e\n\u003cth\u003eThree phase, 230\/400 V grid\u003c\/th\u003e\n\u003cth\u003eThree phase, 277\/480 V grid\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum optimisers per string\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum optimisers per string\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum continuous power per string\u003c\/td\u003e\n\u003ctd\u003e5700 W\u003c\/td\u003e\n\u003ctd\u003e5625 W\u003c\/td\u003e\n\u003ctd\u003e11,250 W\u003c\/td\u003e\n\u003ctd\u003e12,750 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum allowed connected power per string\u003c\/td\u003e\n\u003ctd\u003e6800 W, subject to the conditions below\u003c\/td\u003e\n\u003ctd\u003eSee inverter-dependent condition below\u003c\/td\u003e\n\u003ctd\u003e13,500 W, subject to the conditions below\u003c\/td\u003e\n\u003ctd\u003e15,000 W, subject to the conditions below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel strings of different lengths or orientations\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cul style=\"font-size: 16px;\"\u003e\n\u003cli\u003eDo not mix S-series and P-series optimisers in the same string in new installations.\u003c\/li\u003e\n\u003cli\u003eFor multiple-string designs, the stated maximum connected power is permitted only when the connected-power difference between strings is 2000 W or less.\u003c\/li\u003e\n\u003cli\u003eIf inverter rated AC power is no greater than maximum continuous power per string, connected power per string may reach the inverter’s maximum DC input power, subject to SolarEdge’s Single String Design Guidelines.\u003c\/li\u003e\n\u003cli\u003eThe 6800 W Home Wave figure applies to inverters rated at least 8000 W AC and connected to at least two strings.\u003c\/li\u003e\n\u003cli\u003eValidate the final design against the exact inverter model, current manufacturer guidance and the installation manual.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eDocuments available for download\u003c\/h2\u003e\n\u003cul style=\"font-size: 18px;\"\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/SPV425-430-R54PDTL_datasheet.pdf?v=1791877466\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eSolarEdge SPV425 \/ SPV430-R54PDTL Smart Module Datasheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/se-smart-modules-installation-guide.pdf?v=1791877571\" target=\"_blank\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003eSolarEdge Smart Modules Installation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- Before publication, replace the third-party datasheet link with the Energian-hosted copy of the supplied 14 May 2024 datasheet and verify both download links. --\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eShipping\u003c\/h2\u003e\n\u003cp\u003eAvailable for delivery to the UK, Ireland, Africa, the Caribbean and worldwide. If a shipping rate is not shown at checkout, please contact us on \u003ca href=\"tel:+442080640335\"\u003e+44 2080640335\u003c\/a\u003e or \u003ca href=\"mailto:info@energian.co.uk\"\u003einfo@energian.co.uk\u003c\/a\u003e for a quote.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eUK expert support\u003c\/h2\u003e\n\u003cp\u003eUK expert support is available for module selection, SolarEdge inverter compatibility, string design, mounting and complete solar PV system planning. Contact Energian with any questions or support requests by phone, email or live chat, or visit our office for an in-person consultation.\u003c\/p\u003e\n\u003cp\u003eWhere your system requires professional installation, Energian can arrange installation through trusted partners.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"SolarEdge","offers":[{"title":"Default Title","offer_id":58202243924350,"sku":"SPV430-R54PDTL","price":93.2,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Solaredge-430w.png?v=1791877654","url":"https:\/\/www.energian.co.uk\/products\/solaredge-430w-mono-half-cut-topcon-solar-panel-with-built-in-optimiser","provider":"Energian","version":"1.0","type":"link"}