{"product_id":"pylontech-bms-for-powercube-h2-battery-system","title":"PYLONTECH BMS for PowerCube H2 Battery System","description":"\u003cdiv style=\"font-family: Helvetica,Arial,sans-serif; color: #333; line-height: 1.6; max-width: 900px; margin: 0 auto; font-size: 18px;\"\u003e\n\u003ch1 style=\"font-size: 32px; line-height: 1.25; margin-bottom: 18px; text-align: center;\"\u003e\u003cstrong\u003ePylontech BMS for PowerCube H2 Battery System\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eManage and monitor a compatible PowerCube H2 high-voltage battery string through a dedicated Pylontech BMS controller.\u003c\/li\u003e\n\u003cli\u003eRS485 and CAN communication for integration with an approved inverter or power conversion system.\u003c\/li\u003e\n\u003cli\u003eRack-mounted controller with a 200–1000V DC operating range and 100A maximum charge\/discharge rating, subject to the battery system’s lower limits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 26px; line-height: 1.3;\"\u003ePylontech PowerCube H2 battery management\u003c\/h2\u003e\n\u003cp\u003eThe Pylontech BMS for PowerCube H2 Battery System provides the controller required to manage a compatible high-voltage battery string. It forms part of the PowerCube battery-management architecture, coordinating battery operation and communication with the connected inverter. This listing is for the BMS controller, not a complete battery rack; battery modules, rack, cables and other system equipment must be specified separately.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 26px; line-height: 1.3;\"\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for the Pylontech PowerCube H1\/H2 battery family, with the correct controller revision and system configuration.\u003c\/li\u003e\n\u003cli\u003e200–1000V DC controller working and system operating voltage range.\u003c\/li\u003e\n\u003cli\u003e100A maximum controller charge and discharge ratings; actual permitted current is governed by the battery modules, BMS commands and inverter.\u003c\/li\u003e\n\u003cli\u003eRS485\/CAN communication and 8W specified self-consumption.\u003c\/li\u003e\n\u003cli\u003e442 × 390 × 132mm rack-mounted format with IP20 protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 26px; line-height: 1.3;\"\u003eWhere to use\u003c\/h2\u003e\n\u003cp\u003eUse as part of an approved PowerCube H2 installation serving commercial premises, warehouses, workshops or other sites requiring high-voltage battery storage. It can also be specified as a replacement controller where Pylontech confirms compatibility with the existing battery modules, firmware and inverter.\u003c\/p\u003e\n\u003cp\u003eThis controller is not a universal BMS for generic 48V batteries and is not a standalone charger or inverter. Check the exact part number, controller revision, inverter compatibility, communication cables and permitted module count before ordering. Newer controller versions must not be assumed interchangeable with older systems.\u003c\/p\u003e\n\u003cp\u003eInstallation and commissioning require a qualified installer experienced in high-voltage battery systems. The IP20 equipment requires a suitable dry, protected installation location. Contact our UK expert support team for system checks or assistance through trusted installation partners.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 26px; line-height: 1.3;\"\u003eTechnical specifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 17px; line-height: 1.5;\" border=\"1\" cellpadding=\"10\"\u003e\n\u003cthead style=\"background: #f2f2f2;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eController specification\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003ePylontech\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eBattery management system \/ battery-string controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController model in controller specification document\u003c\/td\u003e\n\u003ctd\u003eSC1000-100S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController name in attached PowerCube H2 system datasheet\u003c\/td\u003e\n\u003ctd\u003eSC1000-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelated battery systems\u003c\/td\u003e\n\u003ctd\u003ePowerCube H1 \/ H2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController working voltage\u003c\/td\u003e\n\u003ctd\u003e200–1000V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem operation voltage\u003c\/td\u003e\n\u003ctd\u003e200–1000V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum controller charge current\u003c\/td\u003e\n\u003ctd\u003e100A; battery-string limits apply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge voltage\u003c\/td\u003e\n\u003ctd\u003e200–1000V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum controller discharge current\u003c\/td\u003e\n\u003ctd\u003e100A; battery-string limits apply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelf-consumption power\u003c\/td\u003e\n\u003ctd\u003e8W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions, width × depth × height\u003c\/td\u003e\n\u003ctd\u003e442 × 390 × 132mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS485 \/ CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController weight\u003c\/td\u003e\n\u003ctd\u003e8.2kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating life stated in controller document\u003c\/td\u003e\n\u003ctd\u003e15 years; not a warranty term\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController operating temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +65°C; battery-system temperature limits still apply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController storage temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct certification entries in controller document\u003c\/td\u003e\n\u003ctd\u003eTÜV, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"font-size: 22px; line-height: 1.3;\"\u003ePowerCube H2 system reference specifications\u003c\/h3\u003e\n\u003cp\u003eThe following figures describe the battery system in the attached datasheet, not the BMS sold alone. The full reference rack contains 12 H48074 modules. The symbol “n” means the number of modules in the series string, from 5 to 12 for this documented configuration.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 17px; line-height: 1.5;\" border=\"1\" cellpadding=\"10\"\u003e\n\u003cthead style=\"background: #f2f2f2;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003eBattery-system specification\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003ePowerCube-H2, 576V \/ 74Ah reference configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell technology\u003c\/td\u003e\n\u003ctd\u003eLithium-ion LFP, lithium iron phosphate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery-system capacity\u003c\/td\u003e\n\u003ctd\u003e42.624kWh with 12 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery-system voltage\u003c\/td\u003e\n\u003ctd\u003e576V DC with 12 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery-system amp-hour capacity\u003c\/td\u003e\n\u003ctd\u003e74Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery module\u003c\/td\u003e\n\u003ctd\u003eH48074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule quantity in reference configuration\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule capacity\u003c\/td\u003e\n\u003ctd\u003e3.552kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule voltage\u003c\/td\u003e\n\u003ctd\u003e48V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule amp-hour capacity\u003c\/td\u003e\n\u003ctd\u003e74Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocumented module quantity per rack\u003c\/td\u003e\n\u003ctd\u003e5–12; actual permitted quantity must also match the controller revision and inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharge upper-voltage limit\u003c\/td\u003e\n\u003ctd\u003en × 54V DC; 648V DC for 12 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard operating current\u003c\/td\u003e\n\u003ctd\u003e14.8A; specified for capacity measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal operating current\u003c\/td\u003e\n\u003ctd\u003e37A; operating current communicated by the BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating current\u003c\/td\u003e\n\u003ctd\u003e74A peak for 15 seconds; not a continuous rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge lower-voltage limit\u003c\/td\u003e\n\u003ctd\u003en × 43.5V DC; 522V DC for 12 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e95%, as stated in the system datasheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth of discharge\u003c\/td\u003e\n\u003ctd\u003e90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem dimensions, width × depth × height\u003c\/td\u003e\n\u003ctd\u003e600 × 505 × 2130mm for the reference rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem communication\u003c\/td\u003e\n\u003ctd\u003eRS485 \/ CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem protection class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem weight\u003c\/td\u003e\n\u003ctd\u003e(n × 32) + 77kg; 461kg for 12 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating life stated in system datasheet\u003c\/td\u003e\n\u003ctd\u003e15+ years; not a warranty term\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating cycle life\u003c\/td\u003e\n\u003ctd\u003e5,000 cycles; test conditions are not stated in the supplied sheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem operating temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem storage temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct certification entries\u003c\/td\u003e\n\u003ctd\u003eIEC 62619, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport certification entry\u003c\/td\u003e\n\u003ctd\u003eUN38.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery-controller dimensions, width × depth × height\u003c\/td\u003e\n\u003ctd\u003e442 × 390 × 132mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery-module dimensions, width × depth × height\u003c\/td\u003e\n\u003ctd\u003e442 × 390 × 132mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"font-size: 26px; line-height: 1.3;\"\u003eShipping and UK expert support\u003c\/h2\u003e\n\u003cp\u003eShipping is available to the UK, Ireland, Africa, the Caribbean and worldwide. If a shipping rate is not shown at checkout, contact us on \u003ca href=\"tel:+442080640335\"\u003e+44 2080640335\u003c\/a\u003e or \u003ca href=\"mailto:info@energian.co.uk\"\u003einfo@energian.co.uk\u003c\/a\u003e for a quote.\u003c\/p\u003e\n\u003cp\u003eUK expert support is available for compatibility checks, product questions and support requests. Contact us by phone, email or live chat, or visit our office for an in-person consultation. Where system design or installation is required, we can suggest trusted installation partners.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 26px; line-height: 1.3;\"\u003eDocuments available for download\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/BMS_Unit_Datasheet.pdf?v=1791624667\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" target=\"_blank\"\u003ePylontech PowerCube \u003c\/a\u003e\u003ca href=\"https:\/\/solarsell.co.uk\/media\/catalog\/product\/attachments\/pyl-pc-sc1000-100-bms\/InstallationManual-SolarSell.pdf\" rel=\"noopener\" target=\"_blank\"\u003eH1\/H2-V2\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/BMS_Unit_Datasheet.pdf?v=1791624667\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" target=\"_blank\"\u003e BMS datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Pylontech-PowerCube-H1H2_Operation_Manual_V2.4.pdf?v=1791624792\" target=\"_blank\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\"\u003ePylontech PowerCube H1\/H2-V2 operation manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- Suggested image alt text: Pylontech BMS controller for PowerCube H2 high-voltage battery system --\u003e \u003c!-- Suggested SEO meta description: Pylontech BMS for PowerCube H2 battery systems. Rack-mounted high-voltage controller with CAN\/RS485 communication and UK expert support. --\u003e\n\u003c\/div\u003e","brand":"Pylontech","offers":[{"title":"Default Title","offer_id":58185920708990,"sku":"PYL-PC-SC1000-100-BMS","price":333.18,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/pyl-pc-sc1000-100-bms.jpg?v=1791624882","url":"https:\/\/www.energian.co.uk\/products\/pylontech-bms-for-powercube-h2-battery-system","provider":"Energian","version":"1.0","type":"link"}