{"product_id":"bimson-power-ats-automatic-transfer-switch-for-diesel-generators","title":"Bimson Power ATS - Automatic Transfer Switch for Diesel Generators","description":"\u003cdiv style=\"font-size: 18px; line-height: 1.6; color: #222;\"\u003e\n\u003ch1 style=\"font-size: 32px; line-height: 1.25; margin: 0px 0px 16px; text-align: center;\"\u003e\u003cstrong\u003eBIMSON POWER ATS – Automatic Transfer Switch for Diesel Generators\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatically starts a compatible diesel generator during a mains failure and transfers essential loads to backup power.\u003c\/li\u003e\n\u003cli\u003eReturns loads to mains supply when power is restored, then stops the generator automatically.\u003c\/li\u003e\n\u003cli\u003eSupports 230 V single-phase and 415 V three-phase installations, with a built-in 2 A battery charger.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eAutomatic backup power for compatible diesel generators\u003c\/h2\u003e\n\u003cp\u003eThe BIMSON POWER ATS Automatic Transfer Switch for Diesel Generators provides automatic mains-to-generator changeover for compatible generators with an ATS connection. It monitors the incoming mains supply, starts the generator when supply is lost or low, and transfers the connected load once generator power is available.\u003c\/p\u003e\n\u003cp\u003eWhen the mains supply returns, the ATS transfers the load back to mains power and stops the generator after approximately 15 seconds. Use it for backup supplies where selected circuits need to remain operational during a power cut, such as workshops, farms, small commercial sites and essential building services. \u003c\/p\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eATS multi phase panel\u003c\/strong\u003e suits all Warrior diesel models from 4kW to 15kW in both single \u0026amp; three phase (MUST have ATS Input socket on generator panel)\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic start and changeover:\u003c\/strong\u003e starts a compatible generator within six seconds of a mains failure or low incoming supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic mains restoration:\u003c\/strong\u003e transfers back to mains power on restoration and stops the generator approximately 15 seconds later.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle- and three-phase support:\u003c\/strong\u003e wiring diagrams are provided for 230 V single-phase and 415 V three-phase systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in battery charger:\u003c\/strong\u003e 2 A battery charging current helps maintain the generator starter battery while the generator is not running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault indication and manual override:\u003c\/strong\u003e red fault light, three automatic start attempts, Auto\/Manual control and an internal manual lever override.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eWhere to use\u003c\/h2\u003e\n\u003cp\u003eSuitable for compatible BIMSON POWER and Warrior diesel generators with the required ATS port. It is intended for emergency standby applications where automatic generator start and controlled changeover are needed for a dedicated consumer unit, essential circuits or selected equipment. \u003c\/p\u003e\n\u003cp\u003eThis product must be installed and commissioned by a qualified electrician or trusted generator-installation partner. They must confirm generator compatibility, phase configuration, cable and protective-device sizing, earthing, neutral arrangement and anti-backfeed protection before use. \u003c\/p\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eTechnical specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 17px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e190102000010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eAutomatic Transfer Switch (ATS) panel for diesel generators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eSupported supply configurations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e230 V single-phase; 415 V three-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eATS current rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eGenerator start timing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWithin 6 seconds of mains supply loss or low supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eGenerator load application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eAfter approximately 5–6 seconds of generator running in automatic mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eStart attempts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e3 attempts; red fault indicator illuminates if unsuccessful\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eMains restoration \/ generator stop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eLoad transfers to mains; generator stops approximately 15 seconds later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eBattery charger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBuilt-in; 2 A charging current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eControls\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eAuto\/Manual button, key switch, manual handle and padlock isolation provision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMains supply, generator supply, automatic mode and red fault indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eATS port configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e12 V power; start relay; fuel oil; flywheel-frequency sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eGenerator control cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eATS input cable supplied for connection to the generator control panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eDiesel-generator ignition position for automatic operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eDocuments available for download\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Bimson_Power_ATS-Diesel-Manual.pdf?v=1785331945\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" target=\"_blank\"\u003eBIMSON POWER ATS Installation and Operator Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eShipping\u003c\/h2\u003e\n\u003cp\u003eAvailable for shipping to the UK, Ireland, Africa, the Caribbean and worldwide. If the shipping rate is not shown at checkout, contact us on \u003ca href=\"tel:+442080640335\"\u003e+44 2080 640335\u003c\/a\u003e or \u003ca href=\"mailto:info@energian.co.uk\"\u003einfo@energian.co.uk\u003c\/a\u003e for a quote.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 26px;\"\u003eUK expert support\u003c\/h2\u003e\n\u003cp\u003eUK expert support is available for generator compatibility, ATS selection and standby-power system design. Contact Energian by phone, email or live chat, or visit our office for an in-person consultation.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Bimson Power","offers":[{"title":"Default Title","offer_id":57763618783614,"sku":null,"price":419.28,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/BimsonPower_190102000010_Diesel-ATS.webp?v=1785332258","url":"https:\/\/www.energian.co.uk\/products\/bimson-power-ats-automatic-transfer-switch-for-diesel-generators","provider":"Energian","version":"1.0","type":"link"}