{"title":"Sungrow","description":"","products":[{"product_id":"sungrow-3-phase-25kw-commercial-3-phase-hybrid-inverter","title":"Sungrow SH25T 25kW Commercial 3-Phase Hybrid Inverter","description":"\u003cdiv style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003c!-- A. Product Title \/ Heading --\u003e\n\u003ch1 style=\"text-align: center;\"\u003eSungrow SH25T 25 kW Commercial Hybrid 3‑Phase Inverter\u003c\/h1\u003e\n\u003c!-- B. Key value proposition --\u003e\n\u003cul\u003e\n\u003cli\u003e25 kW three‑phase hybrid inverter for small commercial, light industrial and logistics sites needing reliable backup and self‑consumption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eThe \u003c\/span\u003eSungrow SH25T inverter\u003cspan\u003e requires a \u003c\/span\u003eminimum of 3 and a maximum of 8 \u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/www.energian.co.uk\/collections\/solar-batteries\/products\/sungrow-sbh-5kwh-lifepo4-battery-system-up-to-40kwh-in-parallel\" target=\"_blank\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\"\u003eSBH050 (5.0 kWh) battery modules\u003c\/a\u003e\u003c\/span\u003e per SBH battery tower\u003cspan\u003e for stable operation with this inverter family.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOne or two 15-40kWh battery towers each can be connected to a single SH25T via a Y‑connector (parallel cable\u003cstrong\u003e)\u003c\/strong\u003e, with both towers required to be identical in model, module count, and size. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eSupports PV and lithium battery storage with fast 50 A charge \/ discharge for peak‑shaving and backup.\u003c\/li\u003e\n\u003cli\u003eBuilt‑in 63 A bypass and seamless switchover for whole‑load or critical‑load backup with compatible switchgear.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- C. Brief description --\u003e\n\u003cp\u003eThe Sungrow SH25T is a 25 kW three‑phase hybrid inverter designed for commercial and industrial applications where uptime matters. It combines high‑voltage PV input with a lithium battery connection, providing grid‑tied operation, backup supply and flexible energy management in one compact unit. Typical uses include warehouses, retail units, offices and small industrial sites looking to reduce grid consumption and maintain power to critical loads during outages.\u003c\/p\u003e\n\u003c!-- D. Key features --\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e25 kW three‑phase hybrid operation with recommended max. PV array size up to 50 kWp and lithium battery support.\u003c\/li\u003e\n\u003cli\u003eBuilt‑in 63 A bypass and backup function with rated backup power 25 kW \/ 25 kVA and peak output 36.5 kW \/ 36.5 kVA for 10 s (with sufficient PV \/ battery power).\u003c\/li\u003e\n\u003cli\u003eThree independent MPPTs, up to 1000 V DC input, and up to 16 A per PV string for modern high‑current modules.\u003c\/li\u003e\n\u003cli\u003eIndoor or outdoor wall‑mounted installation with IP65 enclosure and quiet operation suitable for commercial plant rooms and service areas.\u003c\/li\u003e\n\u003cli\u003eIntegrated protections including DC\/AC surge protection (Type II), anti‑islanding and leakage current protection, plus RS485, WLAN, Ethernet and CAN communications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- Practical applications --\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\n\u003cp\u003eThe SH25T is well suited to rooftop PV and battery systems on small warehouses, last‑mile logistics depots, chilled storage, trade counters and office buildings where three‑phase loads and backup are required. It can be used with compatible lithium battery banks for night‑time operation, peak‑shaving and short‑duration backup of lighting, IT, refrigeration and other critical services.\u003c\/p\u003e\n\u003c!-- Installation \/ support --\u003e\n\u003ch2\u003eInstallation and UK support\u003c\/h2\u003e\n\u003cp\u003eThis inverter must be installed and commissioned by a suitably qualified electrician or solar installer, as part of a correctly designed three‑phase PV and battery system with appropriate protection, switchgear and grid approvals where required. Energian can connect you with trusted installation partners for full system design, installation and commissioning across the UK.\u003c\/p\u003e\n\u003cp\u003eUK expert support is available – contact Energian by phone, email or live chat for help with system sizing, compatibility checks and project support, or visit our office for an in‑person consultation.\u003c\/p\u003e\n\u003c!-- E. Technical specifications --\u003e\n\u003ch2\u003eTechnical specifications – Sungrow SH25T\u003c\/h2\u003e\n\u003ch3\u003eInput (DC)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRecommended max. PV input power: 50000 Wp\u003c\/li\u003e\n\u003cli\u003eMax. PV input voltage*: 1000 V\u003c\/li\u003e\n\u003cli\u003eMin. PV input voltage \/ Startup input voltage: 150 V \/ 180 V\u003c\/li\u003e\n\u003cli\u003eRated PV input voltage: 600 V\u003c\/li\u003e\n\u003cli\u003eMPPT operating voltage range**: 150 V – 950 V\u003c\/li\u003e\n\u003cli\u003eNo. of independent MPP trackers: 3\u003c\/li\u003e\n\u003cli\u003eNo. of PV strings per MPPT: 2 \/ 2 \/ 1\u003c\/li\u003e\n\u003cli\u003eMax. PV input current: 80 A (32 A \/ 32 A \/ 16 A)\u003c\/li\u003e\n\u003cli\u003eMax. DC short‑circuit current: 100 A (40 A \/ 40 A \/ 20 A)\u003c\/li\u003e\n\u003cli\u003eMax. current for input connector: 30 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBattery data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBattery type: Li‑ion battery\u003c\/li\u003e\n\u003cli\u003eBattery voltage range: 100 V – 700 V\u003c\/li\u003e\n\u003cli\u003eMax. charge \/ discharge current***: 50 A \/ 50 A\u003c\/li\u003e\n\u003cli\u003eMax. charge \/ discharge power: 30000 W \/ 25000 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInput and Output (AC)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMax. AC power from grid****: 43000 VA\u003c\/li\u003e\n\u003cli\u003eRated AC output power: 25000 W\u003c\/li\u003e\n\u003cli\u003eMax. AC output apparent power: 25000 VA\u003c\/li\u003e\n\u003cli\u003eMax. AC output current: 37.9 A\u003c\/li\u003e\n\u003cli\u003eRated AC voltage: 3 \/ N \/ PE, 220 V \/ 380 V; 230 V \/ 400 V; 240 V \/ 415 V\u003c\/li\u003e\n\u003cli\u003eAC voltage range: 270 V – 480 V\u003c\/li\u003e\n\u003cli\u003eRated grid frequency: 50 Hz \/ 60 Hz\u003c\/li\u003e\n\u003cli\u003eGrid frequency range: 45 Hz – 55 Hz \/ 55 Hz – 65 Hz\u003c\/li\u003e\n\u003cli\u003eHarmonic (THD): \u0026lt; 3 % (of rated power)\u003c\/li\u003e\n\u003cli\u003ePower factor at rated power \/ Adjustable power factor: \u0026gt; 0.99 \/ 0.8 leading to 0.8 lagging\u003c\/li\u003e\n\u003cli\u003eFeed‑in phases \/ connection phases: 3 \/ 3‑N‑PE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBackup data (on‑grid mode)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMax. output power for backup load****: 43000 W\u003c\/li\u003e\n\u003cli\u003eMax. output current for backup load: 3 × 63 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBackup data (off‑grid mode)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated voltage: 3 \/ N \/ PE, 220 \/ 380 V; 230 \/ 400 V; 240 \/ 415 V (± 2 %)\u003c\/li\u003e\n\u003cli\u003eRated frequency: 50 Hz \/ 60 Hz (± 0.2 %)\u003c\/li\u003e\n\u003cli\u003eTHDV (at linear load): 2 %\u003c\/li\u003e\n\u003cli\u003eBackup switch time: \u0026lt; 10 ms\u003c\/li\u003e\n\u003cli\u003eRated output power: 25000 W \/ 25000 VA\u003c\/li\u003e\n\u003cli\u003ePeak output power*****: 36500 W \/ 36500 VA, 10 s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEfficiency\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMax. efficiency \/ European efficiency: 98.2 % \/ 97.8 %\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProtection \u0026amp; functions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGrid monitoring: Yes\u003c\/li\u003e\n\u003cli\u003eDC reverse polarity protection: Yes\u003c\/li\u003e\n\u003cli\u003eAC short‑circuit protection: Yes\u003c\/li\u003e\n\u003cli\u003eLeakage current protection: Yes\u003c\/li\u003e\n\u003cli\u003eDC switch (solar): Yes\u003c\/li\u003e\n\u003cli\u003eSurge protection: DC Type II \/ AC Type II\u003c\/li\u003e\n\u003cli\u003ePID zero: Yes\u003c\/li\u003e\n\u003cli\u003eBattery input reverse polarity protection: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGeneral data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTopology (solar \/ battery): Transformerless \/ Transformerless\u003c\/li\u003e\n\u003cli\u003eDegree of protection: IP65\u003c\/li\u003e\n\u003cli\u003eDimensions (W × H × D): 620 mm × 480 mm × 245 mm\u003c\/li\u003e\n\u003cli\u003eWeight: 40 kg\u003c\/li\u003e\n\u003cli\u003eMounting method: Wall‑mounting bracket\u003c\/li\u003e\n\u003cli\u003eOperating ambient temperature range: −25 ℃ – 60 ℃\u003c\/li\u003e\n\u003cli\u003eAllowable relative humidity range (non‑condensing): 0 % – 100 %\u003c\/li\u003e\n\u003cli\u003eCooling method: Fan cooling\u003c\/li\u003e\n\u003cli\u003eMax. operating altitude: 2000 m\u003c\/li\u003e\n\u003cli\u003eNoise (typical): 50 dB(A)\u003c\/li\u003e\n\u003cli\u003eDisplay: LED\u003c\/li\u003e\n\u003cli\u003eCommunication: RS485, WLAN, Ethernet, CAN\u003c\/li\u003e\n\u003cli\u003eDI \/ DO: DI × 4 \/ DO × 2 \/ DRM0\u003c\/li\u003e\n\u003cli\u003eDC connection type: MC4 compatible connector (PV, max. 6 mm²) \/ Plug‑and‑play connector (battery, max. 10 mm²)\u003c\/li\u003e\n\u003cli\u003eAC connection type: Plug‑and‑play connector (max. 16 mm²)\u003c\/li\u003e\n\u003cli\u003eCompliance: IEC \/ EN 62109, IEC 61000‑6, EN 62477‑1, IEC 61727, IEC 62116, IEC 62920, EN 55011, CISPR 11, VDE‑AR‑N‑4105, EN 50549‑1, NRS 097, AS\/NZS 4777.2:2020, TOR Type A, R25, CEI 0‑21\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e* Input voltage exceeding the MPPT operating voltage range triggers inverter protection. ** See user manual for full‑load MPPT voltage range. *** Depending on the connected battery. **** See user manual and configure based on actual load power. ***** Peak output can be reached only if PV and battery power are sufficient.\u003c\/p\u003e\n\u003c!-- F. Shipping --\u003e\n\u003ch2\u003eShipping \u0026amp; availability\u003c\/h2\u003e\n\u003cp\u003eShipping is available to the UK, Ireland, Africa, the Caribbean and worldwide. If a shipping rate is not shown at checkout, please contact us on +44 2080640335 or \u003ca href=\"mailto:info@energian.co.uk\"\u003einfo@energian.co.uk\u003c\/a\u003e for a tailored quote.\u003c\/p\u003e\n\u003c!-- Documents --\u003e\n\u003ch2\u003eDocuments available for download\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Sungrow_SH15_20_25T_Datasheet_-_01_12_2023.pdf?v=1777918009\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eSungrow SH15\/20\/25T datasheet (includes SH25T)\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"\/files\/Sungrow-SH15_20_25T-Datasheet-01-12-2023.pdf\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Sungrow_SH5_6_8_10_12_15_20_25T_User_Manual.pdf?v=1777452582\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" target=\"_blank\"\u003eSungrow SH25T installation and user manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Sungrow_Inverters_Batteries_Compatibility_List_-11_09_2024.pdf?v=1777918007\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eSungrow Inverters Battery Compatibility List\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Sungrow_SH15T_SH20T_SH25T_Multi_Hybrid_System_-_16_04_25.pdf?v=1777918008\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eSungrow Multi Hybrid System Schematic\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Sungrow","offers":[{"title":"Default Title","offer_id":57332851966334,"sku":"SH25T","price":3399.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Sungrow-SH25T-1_870c7051-2166-4fe6-beb1-c9f559dbe4d9.png?v=1777454693"},{"product_id":"sungrow-sh20t-20kw-commercial-3-phase-hybrid-inverter","title":"Sungrow SH20T 20kW Commercial 3-Phase Hybrid Inverter","description":"\u003cdiv style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003c!-- A. Product Title \/ Heading --\u003e\n\u003ch1 style=\"text-align: center;\"\u003eSungrow SH20T 20 kW 3‑Phase Commercial\u003c\/h1\u003e\n\u003ch1 style=\"text-align: center;\"\u003eHybrid Inverter\u003c\/h1\u003e\n\u003c!-- B. Key value proposition --\u003e\n\u003cul\u003e\n\u003cli\u003e20 kW three‑phase hybrid inverter for small commercial, logistics and light industrial sites needing reliable backup and self‑consumption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eThe \u003c\/span\u003eSungrow SH20T inverter\u003cspan\u003e requires a \u003c\/span\u003eminimum of 3 and a maximum of 8 \u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/www.energian.co.uk\/collections\/solar-batteries\/products\/sungrow-sbh-5kwh-lifepo4-battery-system-up-to-40kwh-in-parallel\" style=\"color: rgb(43, 0, 255);\"\u003eSBH050 (5.0 kWh) battery modules\u003c\/a\u003e\u003c\/span\u003e per SBH battery tower\u003cspan\u003e for stable operation with this inverter family.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOne or two 15-40kWh battery towers each can be connected to a single SH20T via a Y‑connector (parallel cable\u003cstrong\u003e)\u003c\/strong\u003e, with both towers required to be identical in model, module count, and size. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eSupports PV and lithium battery storage with 50 A fast charge \/ discharge for peak‑shaving and backup.\u003c\/li\u003e\n\u003cli\u003eBuilt‑in 63 A bypass and 10 ms seamless transfer for whole‑load or critical‑load backup with suitable switchgear.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- C. Brief description --\u003e\n\u003cp\u003eThe Sungrow SH20T is a 20 kW three‑phase hybrid inverter designed for commercial and industrial premises with three‑phase supplies. It combines high‑voltage PV input with a lithium battery connection to provide grid‑tied operation, backup supply and flexible energy management in one compact unit. Typical applications include smaller warehouses, logistics depots, retail units and offices aiming to cut grid consumption and maintain key services during grid outages.\u003c\/p\u003e\n\u003c!-- D. Key features --\u003e\n\u003ch2\u003eSungrow SH20T key features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e20 kW three‑phase hybrid operation with recommended max. PV input power of 40 kWp and lithium battery support.\u003c\/li\u003e\n\u003cli\u003eSupport 100 % unbalance output in backup and on‑grid modes for mixed three‑phase and single‑phase loads.\u003c\/li\u003e\n\u003cli\u003eBuilt‑in 63 A bypass for whole‑home or whole‑site backup and 10 ms seamless switching to protect sensitive equipment.\u003c\/li\u003e\n\u003cli\u003eThree independent MPPTs, up to 1000 V DC input, max. 16 A per string and 80 A total PV input current.\u003c\/li\u003e\n\u003cli\u003eOutdoor‑ready IP65\/C5 enclosure with quiet operation suitable for plant rooms or external walls.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- Practical applications --\u003e\n\u003ch2\u003eTypical commercial applications\u003c\/h2\u003e\n\u003cp\u003eThe SH20T suits rooftop PV and battery systems on small warehouses, last‑mile logistics depots, trade counters and office buildings where three‑phase loads and backup are required. Paired with compatible lithium battery banks, it can support night‑time operation, peak‑shaving and short‑duration backup of lighting, IT, refrigeration and other critical services.\u003c\/p\u003e\n\u003c!-- Installation \/ support --\u003e\n\u003ch2\u003eInstallation and UK support\u003c\/h2\u003e\n\u003cp\u003eThis inverter must be installed and commissioned by a suitably qualified electrician or solar installer as part of a correctly designed three‑phase PV and battery system with appropriate protection, switchgear and grid approvals where required. Energian can introduce trusted installation partners for full system design, installation and commissioning across the UK.\u003c\/p\u003e\n\u003cp\u003eUK expert support is available – contact Energian by phone, email or live chat for help with system sizing, compatibility checks and project support, or visit our office for an in‑person consultation.\u003c\/p\u003e\n\u003c!-- E. Technical specifications --\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003ch3\u003eHeadline functions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupport 100 % unbalance output in backup and on grid mode\u003c\/li\u003e\n\u003cli\u003eMax. 16 A DC input current per string\u003c\/li\u003e\n\u003cli\u003e50 A fast charge \/ discharge current\u003c\/li\u003e\n\u003cli\u003eBuilt‑in 63 A bypass for whole home backup\u003c\/li\u003e\n\u003cli\u003e10 ms seamless switch\u003c\/li\u003e\n\u003cli\u003ePeak output up to 36500 VA (10 s) in backup mode (SH25T)\u003c\/li\u003e\n\u003cli\u003ePlug \u0026amp; Play installation\u003c\/li\u003e\n\u003cli\u003eQuiet operation for indoor or outdoor installation\u003c\/li\u003e\n\u003cli\u003eSupport precise AFCI\u003c\/li\u003e\n\u003cli\u003eIP65\/C5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInput (DC)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInput (DC)\u003c\/li\u003e\n\u003cli\u003eRecommended max. PV input power 30000 Wp 40000 Wp 50000 Wp\u003c\/li\u003e\n\u003cli\u003eMax. PV input voltage * 1000 V\u003c\/li\u003e\n\u003cli\u003eMin. PV input voltage \/ Startup input voltage 150 V \/ 180 V\u003c\/li\u003e\n\u003cli\u003eRated PV input voltage 600 V\u003c\/li\u003e\n\u003cli\u003eMPPT operating voltage range ** 150 V - 950 V\u003c\/li\u003e\n\u003cli\u003eNo. of independent MPP trackers 3\u003c\/li\u003e\n\u003cli\u003eNo. of PV strings per MPPT 2 \/ 2 \/ 1\u003c\/li\u003e\n\u003cli\u003eMax. PV input current 80 A ( 32 A \/ 32 A \/ 16 A )\u003c\/li\u003e\n\u003cli\u003eMax. DC short-circuit current 100 A ( 40 A \/ 40 A \/ 20 A )\u003c\/li\u003e\n\u003cli\u003eMax. current for input connector 30 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBattery data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBattery data\u003c\/li\u003e\n\u003cli\u003eBattery type Li-ion battery\u003c\/li\u003e\n\u003cli\u003eBattery voltage range 100 V - 700 V\u003c\/li\u003e\n\u003cli\u003eMax. charge \/ discharge current *** 50 A \/ 50 A\u003c\/li\u003e\n\u003cli\u003eMax. charge \/ discharge power 30000 W \/ 15000 W 30000 W \/ 20000 W 30000 W \/ 25000 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInput and Output (AC)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInput and Output (AC)\u003c\/li\u003e\n\u003cli\u003eMax. AC power from grid **** 43000 VA\u003c\/li\u003e\n\u003cli\u003eRated AC output power 15000 W 20000 W 25000 W\u003c\/li\u003e\n\u003cli\u003eMax. AC output apparent power 15000 VA 20000 VA 25000 VA\u003c\/li\u003e\n\u003cli\u003eMax. AC output current 22.8 A 30.4 A 37.9 A\u003c\/li\u003e\n\u003cli\u003eRated AC voltage 3 \/ N \/ PE, 220 V \/ 380 V ; 230 V \/ 400 V; 240 V \/ 415 V\u003c\/li\u003e\n\u003cli\u003eAC voltage range 270 V - 480 V\u003c\/li\u003e\n\u003cli\u003eRated grid frequency 50 Hz \/ 60 Hz\u003c\/li\u003e\n\u003cli\u003eGrid frequency range 45 Hz - 55 Hz \/ 55 Hz - 65 Hz\u003c\/li\u003e\n\u003cli\u003eHarmonic (THD) \u0026lt; 3 % ( of rated power )\u003c\/li\u003e\n\u003cli\u003ePower factor at rated power \/ Adjustable power factor \u0026gt; 0.99 \/ 0.8 leading to 0.8 lagging\u003c\/li\u003e\n\u003cli\u003eFeed-in phases \/ connection phases 3 \/ 3-N-PE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBackup data (on‑grid mode)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBackup data(on grid mode)\u003c\/li\u003e\n\u003cli\u003eMax. output power for backup load **** 43000 W\u003c\/li\u003e\n\u003cli\u003eMax. output current for backup load 3 * 63 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBackup data (off‑grid mode)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBackup data(off-grid mode)\u003c\/li\u003e\n\u003cli\u003eRated voltage 3 \/ N \/ PE, 220 \/ 380 V; 230 \/ 400 V; 240 \/ 415 V ( ± 2 % )\u003c\/li\u003e\n\u003cli\u003eRated frequency 50 Hz \/ 60 Hz ( ± 0.2 % )\u003c\/li\u003e\n\u003cli\u003eTHDV ( @Linear load ) 2 %\u003c\/li\u003e\n\u003cli\u003eBackup switch time \u0026lt; 10 ms\u003c\/li\u003e\n\u003cli\u003eRated output power 15000 W \/ 15000 VA 20000 W \/ 20000 VA 25000 W \/ 25000 VA\u003c\/li\u003e\n\u003cli\u003ePeak output power ***** 25500 W \/ 25500 VA ,10 s 32000 W \/ 32000 VA ,10 s 36500 W \/ 36500 VA ,10 s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEfficiency\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEfficiency\u003c\/li\u003e\n\u003cli\u003eMax. efficiency \/ European efficiency 98.1 % \/ 97.6 % 98.2 % \/ 97.8 %\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProtection \u0026amp; Function\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProtection \u0026amp; Function\u003c\/li\u003e\n\u003cli\u003eGrid monitoring Yes\u003c\/li\u003e\n\u003cli\u003eDC reverse polarity protection Yes\u003c\/li\u003e\n\u003cli\u003eAC short-circuit protection Yes\u003c\/li\u003e\n\u003cli\u003eLeakage current protection Yes\u003c\/li\u003e\n\u003cli\u003eDC switch (solar) Yes\u003c\/li\u003e\n\u003cli\u003eSurge protection DC Type II \/ AC Type II\u003c\/li\u003e\n\u003cli\u003ePID zero Yes\u003c\/li\u003e\n\u003cli\u003eBattery input reverse polarity protection Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGeneral data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGeneral data\u003c\/li\u003e\n\u003cli\u003eTopology (solar \/ battery) Transformerless \/ Transformerless\u003c\/li\u003e\n\u003cli\u003eDegree of protection IP65\u003c\/li\u003e\n\u003cli\u003eDimensions (W * H * D) 620 mm * 480 mm * 245 mm\u003c\/li\u003e\n\u003cli\u003eWeight 38 kg 40 kg\u003c\/li\u003e\n\u003cli\u003eMounting method Wall-mounting bracket\u003c\/li\u003e\n\u003cli\u003eOperating ambient temperature range -25 ℃ - 60 ℃\u003c\/li\u003e\n\u003cli\u003eAllowable relative humidity range(Non-condensing) 0 % - 100 %\u003c\/li\u003e\n\u003cli\u003eCooling method Natural convection Fan cooling\u003c\/li\u003e\n\u003cli\u003eMax. operating altitude 2000 m\u003c\/li\u003e\n\u003cli\u003eNoise(Typical) 35 dB ( A ) 35 dB ( A ) 50 dB ( A )\u003c\/li\u003e\n\u003cli\u003eDisplay LED\u003c\/li\u003e\n\u003cli\u003eCommunication RS485, WLAN, Ethernet, CAN\u003c\/li\u003e\n\u003cli\u003eDI \/ DO DI * 4 \/ DO * 2 \/ DRM0\u003c\/li\u003e\n\u003cli\u003eDC connection type MC4 compatible connector ( PV,Max.6 mm² ) \/Plug and play connector ( battery, Max.10 mm² )\u003c\/li\u003e\n\u003cli\u003eAC connection type Plug and play connector ( Max.16 mm² )\u003c\/li\u003e\n\u003cli\u003eCompliance IEC \/ EN 62109, IEC 61000-6, EN 62477-1, IEC 61727, IEC 62116, IEC 62920, EN 55011, CISPR 11, VDE-AR-N-4105, EN 50549-1, NRS 097, AS\/NZS 4777.2:2020, TOR Type A, R25, CEI 0-21\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e* Input voltage exceeding the MPPT operating voltage range triggers inverter protection ** Please refer to the user manual for the full load MPPT voltage range *** Depending on the connected battery **** Please refer to the user manual and modify the settings based on actual load power ***** Can be reached only if PV and battery power is sufficient\u003c\/p\u003e\n\u003c!-- F. Shipping --\u003e\n\u003ch2\u003eShipping \u0026amp; availability\u003c\/h2\u003e\n\u003cp\u003eShipping is available to the UK, Ireland, Africa, the Caribbean and worldwide. If a shipping rate is not shown at checkout, please contact us on +44 2080640335 or \u003ca href=\"mailto:info@energian.co.uk\"\u003einfo@energian.co.uk\u003c\/a\u003e for a quote.\u003c\/p\u003e\n\u003c!-- Documents --\u003e\n\u003ch2\u003eDocuments available for download\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Sungrow_SH15_20_25T_Datasheet.pdf?v=1777452455\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eSungrow SH15\/20\/25T datasheet (includes SH20T)\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca rel=\"noopener\" style=\"color: rgb(43, 0, 255);\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Sungrow_SH5_6_8_10_12_15_20_25T_User_Manual.pdf?v=1777452582\" target=\"_blank\"\u003eSungrow SH20T installation and user manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Sungrow","offers":[{"title":"Default Title","offer_id":57333284307326,"sku":"SH20T","price":3155.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Sungrow-SH20T-1.png?v=1777456387"},{"product_id":"sungrow-sh15t-15kw-commercial-3-phase-hybrid-inverter","title":"Sungrow SH15T 15kW Commercial 3-Phase Hybrid Inverter","description":"\u003cdiv style=\"font-size: 16px; line-height: 1.5;\"\u003e\n\u003c!-- A. Product Title \/ Heading --\u003e\n\u003ch1 style=\"text-align: center;\"\u003eSungrow SH15T 15 kW Commercial 3‑Phase\u003c\/h1\u003e\n\u003ch1 style=\"text-align: center;\"\u003eHybrid Inverter\u003c\/h1\u003e\n\u003c!-- B. Key value proposition --\u003e\n\u003cul\u003e\n\u003cli\u003e15 kW three‑phase hybrid inverter for small commercial and logistics sites needing reliable backup and self‑consumption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eThe \u003c\/span\u003eSungrow SH15T inverter\u003cspan\u003e requires a \u003c\/span\u003eminimum of 3 and a maximum of 8 \u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/www.energian.co.uk\/collections\/solar-batteries\/products\/sungrow-sbh-5kwh-lifepo4-battery-system-up-to-40kwh-in-parallel\" target=\"_blank\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\"\u003eSBH050 (5.0 kWh) battery modules\u003c\/a\u003e\u003c\/span\u003e per SBH battery tower\u003cspan\u003e for stable operation with this inverter family.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOne or two 15-40kWh battery towers each can be connected to a single SH15T via a Y‑connector (parallel cable\u003cstrong\u003e)\u003c\/strong\u003e, with both towers required to be identical in model, module count, and size. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eSupports PV and lithium battery storage with 50 A fast charge \/ discharge for peak‑shaving and backup.\u003c\/li\u003e\n\u003cli\u003eBuilt‑in 63 A bypass and 10 ms seamless switch for whole‑load or critical‑load backup when installed with suitable switchgear.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- C. Brief description --\u003e\n\u003cp\u003eThe Sungrow SH15T is a 15 kW three‑phase hybrid inverter designed for small commercial premises with three‑phase supplies. It combines high‑voltage PV input with a lithium battery connection to provide grid‑tied operation, backup supply and flexible energy management in one compact unit. Typical applications include small warehouses, workshops, retail units and offices looking to cut grid consumption and keep key services running during power cuts.\u003c\/p\u003e\n\u003c!-- D. Key features --\u003e\n\u003ch2\u003eSungrow SH15T key features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e15 kW three‑phase hybrid operation with recommended max. PV input power of 30 kWp and lithium battery support.\u003c\/li\u003e\n\u003cli\u003eSupport 100 % unbalance output in backup and on‑grid mode, suitable for mixed three‑phase and single‑phase loads.\u003c\/li\u003e\n\u003cli\u003eThree independent MPPTs, up to 1000 V DC input, max. 16 A per string and 80 A total PV input current.\u003c\/li\u003e\n\u003cli\u003eOutdoor‑ready IP65\/C5 enclosure and quiet operation with natural convection cooling.\u003c\/li\u003e\n\u003cli\u003eIntegrated protections including DC\/AC surge protection (Type II), AFCI, anti‑islanding, leakage current and reverse polarity protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- Typical applications --\u003e\n\u003ch2\u003eTypical commercial applications\u003c\/h2\u003e\n\u003cp\u003eThe SH15T suits rooftop PV and battery systems on small warehouses, light industrial units, trade counters and office buildings where a three‑phase supply and resilient power are important. Paired with compatible lithium batteries, it can support night‑time operation, peak‑shaving and short‑duration backup of lighting, IT, refrigeration and other critical services.\u003c\/p\u003e\n\u003c!-- Installation \/ support --\u003e\n\u003ch2\u003eInstallation and UK support\u003c\/h2\u003e\n\u003cp\u003eThis inverter must be installed and commissioned by a suitably qualified electrician or solar installer, as part of a correctly designed three‑phase PV and battery system with appropriate protection, switchgear and grid approvals where required. Energian can introduce trusted installation partners for full system design, installation and commissioning across the UK.\u003c\/p\u003e\n\u003cp\u003eUK expert support is available – contact Energian by phone, email or live chat for help with system sizing, compatibility checks and project support, or visit our office for an in‑person consultation.\u003c\/p\u003e\n\u003c!-- E. Technical specifications – all strings from datasheet (mapped to SH15T where values differ by model) --\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003ch3\u003eProduct overview\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSH15\/20\/25T\u003c\/li\u003e\n\u003cli\u003eHybrid Three Phase Inverter\u003c\/li\u003e\n\u003cli\u003eSupport 100 % unbalance output in backup and on grid mode\u003c\/li\u003e\n\u003cli\u003eMax. 16 A DC input current per string\u003c\/li\u003e\n\u003cli\u003e50 A fast charge \/ discharge current\u003c\/li\u003e\n\u003cli\u003eBuilt‑in 63 A bypass for whole home backup\u003c\/li\u003e\n\u003cli\u003e10 ms seamless switch\u003c\/li\u003e\n\u003cli\u003ePeak output up to 36500 VA ( 10 s ) in backup mode ( SH25T )\u003c\/li\u003e\n\u003cli\u003ePlug \u0026amp; Play installation\u003c\/li\u003e\n\u003cli\u003eQuiet operation for indoor or outdoor installation\u003c\/li\u003e\n\u003cli\u003eSupport precise AFCI\u003c\/li\u003e\n\u003cli\u003eIP65\/C5\u003c\/li\u003e\n\u003cli\u003e© 2023 Sungrow Power Supply Co., Ltd. All rights reserved. Subject to change without notice. Version 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eType designation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eType designation SH15T SH20T SH25T\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInput (DC)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInput (DC)\u003c\/li\u003e\n\u003cli\u003eRecommended max. PV input power 30000 Wp 40000 Wp 50000 Wp\u003c\/li\u003e\n\u003cli\u003eMax. PV input voltage * 1000 V\u003c\/li\u003e\n\u003cli\u003eMin. PV input voltage \/ Startup input voltage 150 V \/ 180 V\u003c\/li\u003e\n\u003cli\u003eRated PV input voltage 600 V\u003c\/li\u003e\n\u003cli\u003eMPPT operating voltage range ** 150 V - 950 V\u003c\/li\u003e\n\u003cli\u003eNo. of independent MPP trackers 3\u003c\/li\u003e\n\u003cli\u003eNo. of PV strings per MPPT 2 \/ 2 \/ 1\u003c\/li\u003e\n\u003cli\u003eMax. PV input current 80 A ( 32 A \/ 32 A \/ 16 A )\u003c\/li\u003e\n\u003cli\u003eMax. DC short-circuit current 100 A ( 40 A \/ 40 A \/ 20 A )\u003c\/li\u003e\n\u003cli\u003eMax. current for input connector 30 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBattery data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBattery data\u003c\/li\u003e\n\u003cli\u003eBattery type Li-ion battery\u003c\/li\u003e\n\u003cli\u003eBattery voltage range 100 V - 700 V\u003c\/li\u003e\n\u003cli\u003eMax. charge \/ discharge current *** 50 A \/ 50 A\u003c\/li\u003e\n\u003cli\u003eMax. charge \/ discharge power 30000 W \/ 15000 W 30000 W \/ 20000 W 30000 W \/ 25000 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInput and Output (AC)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInput and Output (AC)\u003c\/li\u003e\n\u003cli\u003eMax. AC power from grid **** 43000 VA\u003c\/li\u003e\n\u003cli\u003eRated AC output power 15000 W 20000 W 25000 W\u003c\/li\u003e\n\u003cli\u003eMax. AC output apparent power 15000 VA 20000 VA 25000 VA\u003c\/li\u003e\n\u003cli\u003eMax. AC output current 22.8 A 30.4 A 37.9 A\u003c\/li\u003e\n\u003cli\u003eRated AC voltage 3 \/ N \/ PE, 220 V \/ 380 V ; 230 V \/ 400 V; 240 V \/ 415 V\u003c\/li\u003e\n\u003cli\u003eAC voltage range 270 V - 480 V\u003c\/li\u003e\n\u003cli\u003eRated grid frequency 50 Hz \/ 60 Hz\u003c\/li\u003e\n\u003cli\u003eGrid frequency range 45 Hz - 55 Hz \/ 55 Hz - 65 Hz\u003c\/li\u003e\n\u003cli\u003eHarmonic (THD) \u0026lt; 3 % ( of rated power )\u003c\/li\u003e\n\u003cli\u003ePower factor at rated power \/ Adjustable power factor \u0026gt; 0.99 \/ 0.8 leading to 0.8 lagging\u003c\/li\u003e\n\u003cli\u003eFeed-in phases \/ connection phases 3 \/ 3-N-PE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBackup data (on‑grid mode)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBackup data(on grid mode)\u003c\/li\u003e\n\u003cli\u003eMax. output power for backup load **** 43000 W\u003c\/li\u003e\n\u003cli\u003eMax. output current for backup load 3 * 63 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBackup data (off‑grid mode)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBackup data(off-grid mode)\u003c\/li\u003e\n\u003cli\u003eRated voltage 3 \/ N \/ PE, 220 \/ 380 V; 230 \/ 400 V; 240 \/ 415 V ( ± 2 % )\u003c\/li\u003e\n\u003cli\u003eRated frequency 50 Hz \/ 60 Hz ( ± 0.2 % )\u003c\/li\u003e\n\u003cli\u003eTHDV ( @Linear load ) 2 %\u003c\/li\u003e\n\u003cli\u003eBackup switch time \u0026lt; 10 ms\u003c\/li\u003e\n\u003cli\u003eRated output power 15000 W \/ 15000 VA 20000 W \/ 20000 VA 25000 W \/ 25000 VA\u003c\/li\u003e\n\u003cli\u003ePeak output power ***** 25500 W \/ 25500 VA ,10 s 32000 W \/ 32000 VA ,10 s 36500 W \/ 36500 VA ,10 s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEfficiency\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEfficiency\u003c\/li\u003e\n\u003cli\u003eMax. efficiency \/ European efficiency 98.1 % \/ 97.6 % 98.2 % \/ 97.8 %\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProtection \u0026amp; Function\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProtection \u0026amp; Function\u003c\/li\u003e\n\u003cli\u003eGrid monitoring Yes\u003c\/li\u003e\n\u003cli\u003eDC reverse polarity protection Yes\u003c\/li\u003e\n\u003cli\u003eAC short-circuit protection Yes\u003c\/li\u003e\n\u003cli\u003eLeakage current protection Yes\u003c\/li\u003e\n\u003cli\u003eDC switch (solar) Yes\u003c\/li\u003e\n\u003cli\u003eSurge protection DC Type II \/ AC Type II\u003c\/li\u003e\n\u003cli\u003ePID zero Yes\u003c\/li\u003e\n\u003cli\u003eBattery input reverse polarity protection Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGeneral data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGeneral data\u003c\/li\u003e\n\u003cli\u003eTopology (solar \/ battery) Transformerless \/ Transformerless\u003c\/li\u003e\n\u003cli\u003eDegree of protection IP65\u003c\/li\u003e\n\u003cli\u003eDimensions (W * H * D) 620 mm * 480 mm * 245 mm\u003c\/li\u003e\n\u003cli\u003eWeight 38 kg 40 kg\u003c\/li\u003e\n\u003cli\u003eMounting method Wall-mounting bracket\u003c\/li\u003e\n\u003cli\u003eOperating ambient temperature range -25 ℃ - 60 ℃\u003c\/li\u003e\n\u003cli\u003eAllowable relative humidity range(Non-condensing) 0 % - 100 %\u003c\/li\u003e\n\u003cli\u003eCooling method Natural convection Fan cooling\u003c\/li\u003e\n\u003cli\u003eMax. operating altitude 2000 m\u003c\/li\u003e\n\u003cli\u003eNoise(Typical) 35 dB ( A ) 35 dB ( A ) 50 dB ( A )\u003c\/li\u003e\n\u003cli\u003eDisplay LED\u003c\/li\u003e\n\u003cli\u003eCommunication RS485, WLAN, Ethernet, CAN\u003c\/li\u003e\n\u003cli\u003eDI \/ DO DI * 4 \/ DO * 2 \/ DRM0\u003c\/li\u003e\n\u003cli\u003eDC connection type MC4 compatible connector ( PV,Max.6 mm² ) \/Plug and play connector ( battery, Max.10 mm² )\u003c\/li\u003e\n\u003cli\u003eAC connection type Plug and play connector ( Max.16 mm² )\u003c\/li\u003e\n\u003cli\u003eCompliance IEC \/ EN 62109, IEC 61000-6, EN 62477-1, IEC 61727, IEC 62116, IEC 62920, EN 55011, CISPR 11, VDE-AR-N-4105, EN 50549-1, NRS 097, AS\/NZS 4777.2:2020, TOR Type A, R25, CEI 0-21\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e* Input voltage exceeding the MPPT operating voltage range triggers inverter protection ** Please refer to the user manual for the full load MPPT voltage range *** Depending on the connected battery **** Please refer to the user manual and modify the settings based on actual load power ***** Can be reached only if PV and battery power is sufficient\u003c\/p\u003e\n\u003c!-- F. Shipping --\u003e\n\u003ch2\u003eShipping \u0026amp; availability\u003c\/h2\u003e\n\u003cp\u003eShipping is available to the UK, Ireland, Africa, the Caribbean and worldwide. If a shipping rate is not shown at checkout, please contact us on +44 2080640335 or \u003ca href=\"mailto:info@energian.co.uk\"\u003einfo@energian.co.uk\u003c\/a\u003e for a quote.\u003c\/p\u003e\n\u003c!-- Documents --\u003e\n\u003ch2\u003eDocuments available for download\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca rel=\"noopener\" style=\"color: rgb(43, 0, 255);\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Sungrow_SH15_20_25T_Datasheet.pdf?v=1777452455\" target=\"_blank\"\u003eSungrow SH15\/20\/25T datasheet (includes SH15T)\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca rel=\"noopener\" style=\"color: rgb(43, 0, 255);\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Sungrow_SH5_6_8_10_12_15_20_25T_User_Manual.pdf?v=1777452582\" target=\"_blank\"\u003eSungrow SH15T installation and user manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Sungrow","offers":[{"title":"Default Title","offer_id":57334372729214,"sku":"SH15T","price":2137.66,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Sungrow-15kW-1.jpg?v=1777465283"},{"product_id":"sungrow-sbh-5kwh-lifepo4-battery-system-up-to-40kwh-in-parallel","title":"Sungrow SBH 5kWh LiFePO4 Battery System up to 40kWh in Parallel","description":"\u003cdiv style=\"font-family: Arial, sans-serif; font-size: 16px; line-height: 1.6; color: #333;\"\u003e\n\u003ch1 style=\"font-size: 32px; font-weight: bold; margin-bottom: 20px; text-align: center;\"\u003eSungrow SBH HV Battery System – 10kWh to 40kWh Modular Storage\u003c\/h1\u003e\n\u003cdiv style=\"background-color: #f4f4f4; padding: 20px; margin-bottom: 20px; border-left: 4px solid #ff6600;\"\u003e\n\u003cul style=\"font-size: 18px; margin: 0; padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eScalable from 10kWh to 40kWh\u003c\/strong\u003e – start small and expand during the system's lifetime as your energy needs grow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e100% depth of discharge\u003c\/strong\u003e – use every watt‑hour of stored energy, with 50A continuous power and up to 28kW from an 8‑module tower\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlug‑and‑play installation\u003c\/strong\u003e – no inter‑module cabling; floor‑stand design for indoor or outdoor use (IP55)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"font-size: 24px; font-weight: bold; margin-top: 30px; margin-bottom: 10px;\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe Sungrow SBH series is a high‑voltage lithium iron phosphate (LiFePO₄) battery system designed for commercial and industrial solar‑plus‑storage projects. Each 5kWh module stacks vertically—from 2 modules (10kWh, SBH100) to 8 modules (40kWh, SBH400)—so you match capacity to load without over‑specifying. The natural‑convection cooling and multi‑stage protection (over\/under voltage, over‑current, temperature, integrated DC breaker) meet CE, IEC 62619, IEC 62040, VDE 2510‑50 and UN 38.3 standards, giving you robust safety credentials for UK logistics, warehouses and off‑grid sites.\u003c\/p\u003e\n\u003cp\u003eUp to 4 SBH battery stacks can be connected in parallel\u003cspan\u003e to a single compatible Sungrow hybrid inverter using up to 4x \u003c\/span\u003e\u003cspan\u003eSungrow Battery Generic Branch \/ Y Connector Set For SBH Parallel Connection (price on request).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 style=\"font-size: 24px; font-weight: bold; margin-top: 30px; margin-bottom: 10px;\"\u003eKey Features\u003c\/h2\u003e\n\u003cul style=\"padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular expansion:\u003c\/strong\u003e add modules during the system's lifetime; each 5kWh module weighs 45kg and slots into the same footprint (675mm wide × 350mm deep)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide operating range:\u003c\/strong\u003e charge 0°C to 50°C, discharge –20°C to 50°C; suitable for unheated buildings and outdoor enclosures\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAN‑bus communication:\u003c\/strong\u003e integrates with compatible Sungrow hybrid inverters for real‑time SOC display and automatic charge\/discharge control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10‑year warranty:\u003c\/strong\u003e subject to conditional application (see warranty letter); prismatic LiFePO₄ cells offer long cycle life at 100% DOD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 24px; font-weight: bold; margin-top: 30px; margin-bottom: 10px;\"\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eIdeal for warehouses with forklift‑charging peaks, remote telecoms sites, agricultural operations requiring overnight backup, and hybrid diesel‑solar microgrids where battery paralleling (via optional Y‑connectors) lets you reach 80kWh+ capacity.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 24px; font-weight: bold; margin-top: 30px; margin-bottom: 10px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 10px; font-size: 15px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #ff6600; color: white;\"\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px; text-align: left;\"\u003eSBH100\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px; text-align: left;\"\u003eSBH150\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px; text-align: left;\"\u003eSBH200\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px; text-align: left;\"\u003eSBH250\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px; text-align: left;\"\u003eSBH300\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px; text-align: left;\"\u003eSBH350\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px; text-align: left;\"\u003eSBH400\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eNumber of modules\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e5\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e6\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e7\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eBattery type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"7\" style=\"border: 1px solid #ddd; padding: 8px;\"\u003eLiFePO₄ Prismatic Cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eBattery module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"7\" style=\"border: 1px solid #ddd; padding: 8px;\"\u003e5.0 kWh, 45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eUsable energy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e10.0 kWh\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e15.0 kWh\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e20.0 kWh\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e25.0 kWh\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e30.0 kWh\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e35.0 kWh\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e40.0 kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e140.8 V\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e211.2 V\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e281.6 V\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e352.0 V\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e422.4 V\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e492.8 V\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e563.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eRated DC power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e7.04 kW\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e10.56 kW\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e14.08 kW\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e17.60 kW\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e21.12 kW\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e24.64 kW\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e28.16 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eOperating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e118.8–160.6 V\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e178.2–240.9 V\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e237.6–321.2 V\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e297–401.5 V\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e356.4–481.8 V\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e415.8–562.1 V\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e475.2–642.4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eMax. continuous charge\/discharge current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"7\" style=\"border: 1px solid #ddd; padding: 8px;\"\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eDepth of discharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"7\" style=\"border: 1px solid #ddd; padding: 8px;\"\u003eMax. 100% DOD (settable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eShort‑circuit current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"7\" style=\"border: 1px solid #ddd; padding: 8px;\"\u003e3500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"7\" style=\"border: 1px solid #ddd; padding: 8px;\"\u003eSOC indicator, Status indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eCommunication interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"7\" style=\"border: 1px solid #ddd; padding: 8px;\"\u003eCAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"7\" style=\"border: 1px solid #ddd; padding: 8px;\"\u003eOver\/under voltage, over‑current, over\/under temperature, DC breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e675×580×350 mm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e675×740×350 mm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e675×900×350 mm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e675×1060×350 mm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e675×1220×350 mm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e675×1380×350 mm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e675×1540×350 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e106 kg\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e151 kg\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e196 kg\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e241 kg\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e286 kg\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e331 kg\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e376 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eInstallation location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"7\" style=\"border: 1px solid #ddd; padding: 8px;\"\u003eIndoor \/ Outdoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eMounting method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"7\" style=\"border: 1px solid #ddd; padding: 8px;\"\u003eFloor stand - \u003ca class=\"tp-link-dark text-truncate d-block\" itemprop=\"name\" title=\"Sungrow SBH Battery Accessory Kit  (AST04844)\" href=\"https:\/\/www.alternergy.co.uk\/shop\/pv-brand-sungrow-217\/sbh-bat-acc-sungrow-sbh-battery-accessory-kit-ast04844-2779\"\u003eSungrow SBH Battery Accessory Kit\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eOperating ambient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"7\" style=\"border: 1px solid #ddd; padding: 8px;\"\u003eCharge: 0°C–50°C; Discharge: –20°C–50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eDegree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"7\" style=\"border: 1px solid #ddd; padding: 8px;\"\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eAllowable relative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"7\" style=\"border: 1px solid #ddd; padding: 8px;\"\u003e0%–95% (no condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eMax. operating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"7\" style=\"border: 1px solid #ddd; padding: 8px;\"\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eCooling method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"7\" style=\"border: 1px solid #ddd; padding: 8px;\"\u003eNatural convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eCertificates\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"7\" style=\"border: 1px solid #ddd; padding: 8px;\"\u003eCE, CEC, IEC 62619, IEC 62040, UN 38.3, VDE 2510‑50, IEC 62477, IEC 63056\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"7\" style=\"border: 1px solid #ddd; padding: 8px;\"\u003e10 years (conditional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top: 10px; font-size: 14px; font-style: italic;\"\u003eTest conditions: 25°C, 100% depth of discharge, 0.2C charge \u0026amp; discharge. Refer to battery warranty letter for conditional application.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 24px; font-weight: bold; margin-top: 30px; margin-bottom: 10px;\"\u003eDocuments Available for Download\u003c\/h2\u003e\n\u003cul style=\"padding-left: 20px;\"\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca style=\"color: rgb(43, 0, 255);\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Sungrow_HV_Battery_SBH100-400_Datasheet_-_26_02_2024_1.pdf?v=1777550430\"\u003e\u003cspan style=\"color: #ff6600;\"\u003e\u003cspan\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eSungrow SBH100–400 Datasheet (PDF)\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Sungrow_HV_SBH100-400_User_Manual_-_13_05_2025.pdf?v=1777550711\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #ff6600;\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Sungrow_HV_SBH100-400_User_Manual_-_13_05_2025.pdf?v=1777550711\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: #ff6600;\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eSungrow SBH Installation \u0026amp; User Manual (PDF\u003c\/span\u003e)\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 24px; font-weight: bold; margin-top: 30px; margin-bottom: 10px;\"\u003eShipping\u003c\/h2\u003e\n\u003cp\u003eAvailable to the UK, Ireland, Africa, the Caribbean and worldwide. If the shipping rate is not shown at checkout, contact us on \u003cstrong\u003e+44 2080640335\u003c\/strong\u003e or \u003ca href=\"mailto:info@energian.co.uk\" style=\"color: #ff6600; text-decoration: none;\"\u003einfo@energian.co.uk\u003c\/a\u003e for a quote.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 24px; font-weight: bold; margin-top: 30px; margin-bottom: 10px;\"\u003eUK Expert Support\u003c\/h2\u003e\n\u003cp\u003eOur team can help you size the SBH system, recommend compatible Sungrow inverters and arrange installation via trusted partners. Contact us with any questions or support requests via phone (\u003cstrong\u003e+44 2080640335\u003c\/strong\u003e), email (\u003ca href=\"mailto:info@energian.co.uk\" style=\"color: #ff6600; text-decoration: none;\"\u003einfo@energian.co.uk\u003c\/a\u003e) or live chat, or visit our office for an in‑person consultation.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Sungrow","offers":[{"title":"3x SBH 5.0kWh + SBH Accessories Kit","offer_id":57343657378174,"sku":"SBH-15.0","price":5873.29,"currency_code":"GBP","in_stock":true},{"title":"4x SBH 5.0kWh + SBH Accessories Kit","offer_id":57343657410942,"sku":"SBH-20.0","price":7613.63,"currency_code":"GBP","in_stock":true},{"title":"5x SBH 5.0kWh + SBH Accessories Kit","offer_id":57343657443710,"sku":"SBH-25.0","price":9353.97,"currency_code":"GBP","in_stock":true},{"title":"6x SBH 5.0kWh + SBH Accessories Kit","offer_id":57343657476478,"sku":"SBH-30.0","price":11094.31,"currency_code":"GBP","in_stock":true},{"title":"7x SBH 5.0kWh + SBH Accessories Kit","offer_id":57343657509246,"sku":"SBH-35.0","price":12834.65,"currency_code":"GBP","in_stock":true},{"title":"8x SBH 5.0kWh + SBH Accessories Kit","offer_id":57343657542014,"sku":"SBH-40.0","price":14574.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/SungrowSBH5.0kWhBatteryModule_ASA00637_-Image3.jpg?v=1777551613"},{"product_id":"sungrow-sg33cx-p2-33kw-commercial-3-phase-inverter","title":"Sungrow SG33CX-P2 33kW Commercial 3-Phase PV Inverter","description":"\u003cdiv style=\"font-size: 16px; line-height: 1.6;\"\u003e\n\u003ch1 style=\"text-align: center;\"\u003eSungrow SG33CX-P2 33 kW Commercial 3‑Phase PV Inverter\u003c\/h1\u003e\n\u003c!-- B. Key value proposition --\u003e\n\u003cul\u003e\n\u003cli\u003e33 kW three‑phase string inverter for medium and large commercial PV systems, with up to 46.2 kWp DC input.\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 98.5% to maximise energy yield from rooftop or ground‑mount arrays.\u003c\/li\u003e\n\u003cli\u003eRobust IP66, C5‑rated enclosure and integrated surge protection for demanding UK industrial and coastal sites.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- C. Brief Description --\u003e\n\u003cp\u003eThe Sungrow SG33CX‑P2 is a 33 kW three‑phase string inverter designed for commercial and industrial solar installations that need reliable, efficient power conversion with straightforward operation and maintenance. It supports up to 46.2 kWp of PV, with three independent MPPTs and built‑in protection features suitable for commercial installations and smaller solar farms. Energian supplies this inverter with UK‑based technical support and can connect you with trusted installation partners where needed.\u003c\/p\u003e\n\u003c!-- D. Key features --\u003e\n\u003ch2\u003eMain features and benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHigh yield with max. 98.5% efficiency and wide 160–1000 V MPPT range for flexible string design.\u003c\/li\u003e\n\u003cli\u003eThree independent MPPT inputs, two strings per MPPT, to handle different roof orientations and partial shading.\u003c\/li\u003e\n\u003cli\u003eIntegrated DC Type I+II and AC Type II surge protection, AFCI and built‑in DC switch for safer operation on commercial sites.\u003c\/li\u003e\n\u003cli\u003eSmart O\u0026amp;M functions including IV curve diagnosis, grid fault record and PV string current monitoring to support remote diagnostics.\u003c\/li\u003e\n\u003cli\u003eIP66, C5 corrosion‑resistant, transformerless design with smart forced‑air cooling, suitable for outdoor mounting up to 4000 m altitude.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTypical applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRooftop PV on warehouses, logistics hubs and distribution centres.\u003c\/li\u003e\n\u003cli\u003eCommercial rooftops for retail parks, offices and light industrial buildings.\u003c\/li\u003e\n\u003cli\u003eGround‑mount arrays for small solar farms, business parks and agricultural sites.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor larger projects, multiple SG33CX‑P2 inverters can be combined within a three‑phase distribution system, subject to appropriate electrical design and local DNO requirements. We recommend using experienced commercial solar installers; Energian can introduce trusted partners on request.\u003c\/p\u003e\n\u003c!-- E. Technical specifications --\u003e\n\u003ch2\u003eTechnical specifications \u003c\/h2\u003e\n\u003ch3\u003eInput (DC)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRecommended max. PV input power: 46.2 kWp.\u003c\/li\u003e\n\u003cli\u003eMax. PV input voltage: 1100 V.\u003c\/li\u003e\n\u003cli\u003eMin. PV input voltage \/ start‑up input voltage: 160 V \/ 200 V.\u003c\/li\u003e\n\u003cli\u003eRated PV input voltage: 600 V.\u003c\/li\u003e\n\u003cli\u003eMPP voltage range: 160 V – 1000 V.\u003c\/li\u003e\n\u003cli\u003eNumber of independent MPPT inputs: 3.\u003c\/li\u003e\n\u003cli\u003eNumber of PV strings per MPPT: 2.\u003c\/li\u003e\n\u003cli\u003eMax. PV input current: 90 A (30 A × 3).\u003c\/li\u003e\n\u003cli\u003eMax. DC short‑circuit current: 120 A (40 A × 3).\u003c\/li\u003e\n\u003cli\u003eMax. current for DC connector: 20 A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOutput (AC)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated AC output power: 33 kW.\u003c\/li\u003e\n\u003cli\u003eMax. AC output apparent power: 36.3 kVA.\u003c\/li\u003e\n\u003cli\u003eMax. AC output current: 55.2 A.\u003c\/li\u003e\n\u003cli\u003eRated AC output current (at 230 V): 47.8 A.\u003c\/li\u003e\n\u003cli\u003eRated AC voltage: 3 \/ N \/ PE, 220 \/ 380 V, 230 \/ 400 V.\u003c\/li\u003e\n\u003cli\u003eAC voltage range: 312 – 480 V.\u003c\/li\u003e\n\u003cli\u003eRated grid frequency: 50 Hz \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003eGrid frequency range: 45 – 55 Hz \/ 55 – 65 Hz.\u003c\/li\u003e\n\u003cli\u003eTotal harmonic distortion (THD): \u0026lt; 3 % at rated power.\u003c\/li\u003e\n\u003cli\u003ePower factor at rated power \/ adjustable power factor: \u0026gt; 0.99 \/ 0.8 leading to 0.8 lagging.\u003c\/li\u003e\n\u003cli\u003eFeed‑in phases \/ connection phases: 3 \/ 3‑N‑PE.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEfficiency\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMax. efficiency: 98.5 %. European efficiency: 98.3 %.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProtection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGrid monitoring: Yes.\u003c\/li\u003e\n\u003cli\u003eDC reverse connection protection: Yes.\u003c\/li\u003e\n\u003cli\u003eAC short‑circuit protection: Yes.\u003c\/li\u003e\n\u003cli\u003eLeakage current protection: Yes.\u003c\/li\u003e\n\u003cli\u003eSurge protection: DC Type I+II \/ AC Type II.\u003c\/li\u003e\n\u003cli\u003eGround fault monitoring: Yes.\u003c\/li\u003e\n\u003cli\u003eIntegrated DC switch: Yes.\u003c\/li\u003e\n\u003cli\u003ePV string current monitoring: Yes.\u003c\/li\u003e\n\u003cli\u003eArc fault circuit interrupter (AFCI): Yes.\u003c\/li\u003e\n\u003cli\u003ePID recovery function: Yes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGeneral data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions (W × H × D): 645 × 575 × 245 mm.\u003c\/li\u003e\n\u003cli\u003eMounting method: Wall‑mounting bracket.\u003c\/li\u003e\n\u003cli\u003eWeight: 38 kg.\u003c\/li\u003e\n\u003cli\u003eTopology: Transformerless.\u003c\/li\u003e\n\u003cli\u003eDegree of protection: IP66.\u003c\/li\u003e\n\u003cli\u003eCorrosion classification: C5.\u003c\/li\u003e\n\u003cli\u003eNight power consumption: \u0026lt; 5 W.\u003c\/li\u003e\n\u003cli\u003eOperating ambient temperature range: −30 to 60 °C.\u003c\/li\u003e\n\u003cli\u003eAllowable relative humidity range (non‑condensing): 0 – 100 %.\u003c\/li\u003e\n\u003cli\u003eCooling method: Smart forced‑air cooling.\u003c\/li\u003e\n\u003cli\u003eMax. operating altitude: 4000 m.\u003c\/li\u003e\n\u003cli\u003eDisplay: LED, Bluetooth + App.\u003c\/li\u003e\n\u003cli\u003eCompatible optimiser: SP600S (optional).\u003c\/li\u003e\n\u003cli\u003eCommunication: RS485; optional WLAN, Ethernet.\u003c\/li\u003e\n\u003cli\u003eDC connection type: EVO2 (max. 6 mm²).\u003c\/li\u003e\n\u003cli\u003eAC connection type: OT terminal (16 – 35 mm²).\u003c\/li\u003e\n\u003cli\u003eAC cable specification: Outside diameter 18 – 38 mm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGrid compliance and support\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGrid compliance: IEC 62109, IEC 61727, IEC 62116, VDE‑AR‑N 4105:2018, IEC 61000‑6‑3, EN 50549‑1, CEI 0‑21 2019, CEI 0‑16 2019, VDE 0126‑1‑1\/A1 VFR 2019, UTE C15‑712‑1:2013, UNE 206007‑1\/RD 1699, UNE 217002, G99.\u003c\/li\u003e\n\u003cli\u003eGrid support functions: Q at night, LVRT, HVRT, active and reactive power control, power ramp rate control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- F. Shipping and support --\u003e\n\u003ch2\u003eShipping information\u003c\/h2\u003e\n\u003cp\u003eShipping is available to the UK, Ireland, Africa, the Caribbean and worldwide. If a shipping rate is not shown at checkout, please contact us on +44 2080640335 or \u003ca href=\"mailto:info@energian.co.uk\"\u003einfo@energian.co.uk\u003c\/a\u003e for a tailored quote.\u003c\/p\u003e\n\u003ch2\u003eUK expert support\u003c\/h2\u003e\n\u003cp\u003eEnergian provides UK‑based technical support for the Sungrow SG33CX‑P2, including help with system design, product selection and commissioning queries. For installations, we recommend working with qualified solar PV contractors; we can introduce trusted partners experienced with commercial three‑phase systems.\u003c\/p\u003e\n\u003cp\u003eIf you have any questions before or after purchase, contact us via phone, email or live chat, or visit our office for an in‑person consultation.\u003c\/p\u003e\n\u003c!-- Documents --\u003e\n\u003ch2\u003eDocuments available for download\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/sungrow_datasheet_sg25-33cx-p2.pdf?v=1777628616\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" target=\"_blank\"\u003eSungrow SG25\/30\/33CX‑P2 datasheet (PDF)\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\n\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/sungrow_installation_guide-sg30_33_40_50cx.pdf?v=1777628814\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" target=\"_blank\"\u003eSungrow SG25\/30\/33CX‑P2 installation manual (PDF)\u003c\/a\u003e\u003c\/span\u003e\u003c!-- A. Product Title\/Heading --\u003e\n\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/sungrow_user_manual-sg30_33_40_50cx_v14.pdf?v=1777629352\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" target=\"_blank\"\u003eSungrow SG25\/30\/33CX‑P2 user manual (PDF)\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Sungrow","offers":[{"title":"Default Title","offer_id":57353012183422,"sku":"SG33CX-P2","price":1727.43,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Sungrow33kW-1.webp?v=1777707889"},{"product_id":"sungrow-sg40cx-p2-40kw-commercial-3-phase-inverter","title":"Sungrow SG40CX-P2 40kW Commercial 3-Phase Inverter","description":"\u003cdiv style=\"font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Helvetica, Arial, sans-serif; font-size: 17px; line-height: 1.6; color: #222;\"\u003e\n\u003ch1 style=\"font-size: 30px; line-height: 1.25; margin: 0px 0px 12px; text-align: center;\"\u003eSungrow SG40CX-P2 40kW Commercial 3-Phase Solar Inverter\u003c\/h1\u003e\n\u003cp style=\"font-size: 17px; color: #555; margin: 0 0 22px 0;\"\u003eMulti-MPPT string inverter for 1000 Vdc commercial PV systems – 40 kW AC, 4 independent MPPTs, IP66, C5 anti-corrosion.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 22px; margin: 22px 0 10px 0;\"\u003eWhy specify the Sungrow SG40CX-P2\u003c\/h2\u003e\n\u003cul style=\"margin: 0 0 22px 20px; padding: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eMore yield from awkward roofs\u003c\/strong\u003e – 4 independent MPPTs with a dynamic shading optimisation mode help recover output on split orientations and partly shaded arrays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFaster, cheaper installs\u003c\/strong\u003e – at 40 kg with a plug-and-play buckle mounting design, two engineers can lift and hang it without a hoist.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt for UK commercial sites\u003c\/strong\u003e – IP66 enclosure, C5 anti-corrosion rating and a –30 °C to 60 °C operating range suit warehouses, farms, factories and coastal logistics depots.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 22px; margin: 22px 0 10px 0;\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 16px 0;\"\u003eThe Sungrow SG40CX-P2 is a transformerless three-phase string inverter rated at 40 kW AC for commercial and industrial rooftop and ground-mount PV systems up to 56 kWp. It accepts up to 8 strings across 4 MPPTs, supports modules above 500 W with a 15 A per-string input, and includes DC Type I+II and AC Type II surge protection plus AFCI 2.0 as standard.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 22px; margin: 22px 0 10px 0;\"\u003eKey features\u003c\/h2\u003e\n\u003cul style=\"margin: 0 0 22px 20px; padding: 0;\"\u003e\n\u003cli\u003e4 MPPTs, 2 strings per MPPT, 15 A per-string – compatible with high-current bifacial and 500 W+ modules.\u003c\/li\u003e\n\u003cli\u003e98.5% maximum efficiency, 98.3% European efficiency.\u003c\/li\u003e\n\u003cli\u003eSmart IV curve diagnosis, PID recovery and grid fault recording for remote operations and maintenance.\u003c\/li\u003e\n\u003cli\u003eG99 compliant for UK grid connection; supports LVRT, HVRT, active\/reactive power control and Q at night.\u003c\/li\u003e\n\u003cli\u003eWall-mounted, smart forced-air cooling, LED indicator with Bluetooth + app commissioning; RS485 standard, WLAN\/Ethernet optional.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 22px; margin: 28px 0 12px 0;\"\u003eTechnical specifications\u003c\/h2\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%; font-size: 16px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eRecommended max. PV input power\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003e56 kWp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eMax. PV input voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003e1100 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eMin. PV input voltage \/ Startup input voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003e160 V \/ 200 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eRated PV input voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eMPPT voltage range\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003e160 V – 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eNo. of independent MPP inputs\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eNo. of PV strings per MPPT\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eMax. PV input current\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003e120 A (30 A × 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eMax. DC short-circuit current\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003e160 A (40 A × 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eMax. current for DC connector\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; background: rgb(244, 246, 248); padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 99.8264%;\" colspan=\"2\"\u003eOutput (AC)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eRated AC output power\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003e40 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eMax. AC output apparent power\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003e44 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eMax. AC output current\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003e66.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eRated AC output current (at 230 V)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003e58 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eRated AC voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003e3 \/ N \/ PE, 220 \/ 380 V, 230 \/ 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eAC voltage range\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003e312 V – 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eRated grid frequency\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003e50 Hz \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eGrid frequency range\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003e45 Hz – 55 Hz \/ 55 Hz – 65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eHarmonic (THD)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003e\u0026lt; 3% (at rated power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003ePower factor \/ Adjustable power factor\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003e\u0026gt; 0.99 \/ 0.8 leading – 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eFeed-in phases \/ AC connection\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003e3 \/ 3-N-PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; background: rgb(244, 246, 248); padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 99.8264%;\" colspan=\"2\"\u003eEfficiency\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eMax. efficiency \/ European efficiency\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003e98.5% \/ 98.3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; background: rgb(244, 246, 248); padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 99.8264%;\" colspan=\"2\"\u003eGeneral data\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003e645 mm × 575 mm × 245 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003e40 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eMounting method\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003eWall-mounting bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eTopology\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003eTransformerless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eDegree of protection\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eNight power consumption\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003e\u0026lt; 7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eCorrosion\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003eC5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eOperating ambient temperature range\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003e–30 °C to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eAllowable relative humidity (non-condensing)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003e0% – 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eCooling method\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003eSmart forced air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eMax. operating altitude\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003e4000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003eLED, Bluetooth + APP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eCommunication\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003eRS485 \/ Optional: WLAN, Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eDC connection type\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003eEvo2 (max. 6 mm²)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eAC connection type\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003eOT terminal (16–35 mm²)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eAC cable specification\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003eOutside diameter 18 mm – 38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eGrid compliance\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003eIEC 62109, IEC 61727, IEC 62116, VDE-AR-N 4105:2018, IEC 61000-6-3, EN 50549-1, CEI 0-21 2019, CEI 0-16 2019, VDE 0126-1-1\/A1, VFR 2019, UTE C15-712-1:2013, UNE 206007-1\/RD 1699, UNE 217002, G99, IEC 63027\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 60.9651%;\"\u003eGrid support\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid rgb(226, 226, 226); width: 38.8613%;\"\u003eQ at night function, LVRT, HVRT, active \u0026amp; reactive power control, power ramp rate control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-size: 22px; margin: 28px 0 10px 0;\"\u003eDocuments available for download\u003c\/h2\u003e\n\u003cul style=\"margin: 0 0 22px 20px; padding: 0;\"\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca rel=\"noopener\" style=\"color: rgb(43, 0, 255);\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Sungrow_Datasheet_SG40CX-P12-V12_1.pdf?v=1777732644\" target=\"_blank\"\u003eSungrow SG36\/40\/50CX-P2 datasheet (PDF)\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca rel=\"noopener\" style=\"color: rgb(43, 0, 255);\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Sungrow_User_Manual-SG25_30_33_36_40_50CX-P2.pdf?v=1777733327\" target=\"_blank\"\u003eSungrow SG25\/30\/33\/36\/40\/50CX-P2 user manual (PDF)\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca rel=\"noopener\" style=\"color: rgb(43, 0, 255);\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Sungrow_Installation_Guide-SG25_30_33_36_40_50CX-P2.pdf?v=1777733154\" target=\"_blank\"\u003eQuick installation guide (PDF)\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size: 22px; margin: 22px 0 10px 0;\"\u003eInstallation\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 16px 0;\"\u003eThe SG40CX-P2 is a commercial three-phase grid-tied inverter and must be installed and commissioned by a qualified electrical contractor with G99 application sign-off. Energian works with trusted UK installation partners – contact us before ordering and we'll match you with an installer in your area or scope the job remotely from your single-line diagram.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 22px; margin: 22px 0 10px 0;\"\u003eShipping\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 16px 0;\"\u003eAvailable to the UK, Ireland, Africa, the Caribbean and worldwide. If a shipping rate is not shown at checkout, contact us on \u003ca href=\"tel:+442080640335\"\u003e+44 20 8064 0335\u003c\/a\u003e or \u003ca href=\"mailto:info@energian.co.uk\"\u003einfo@energian.co.uk\u003c\/a\u003e for a quote.\u003c\/p\u003e\n\u003ch2 style=\"font-size: 22px; margin: 22px 0 10px 0;\"\u003eUK expert support\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 16px 0;\"\u003eTalk to a UK-based renewables specialist before you buy. Reach us by phone on \u003ca href=\"tel:+442080640335\"\u003e+44 20 8064 0335\u003c\/a\u003e, by email at \u003ca href=\"mailto:info@energian.co.uk\"\u003einfo@energian.co.uk\u003c\/a\u003e, via live chat on \u003ca rel=\"noopener\" href=\"https:\/\/www.energian.co.uk\" target=\"_blank\"\u003eenergian.co.uk\u003c\/a\u003e, or visit our office for an in-person consultation.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Sungrow","offers":[{"title":"Default Title","offer_id":57355938791806,"sku":"SG40CX-P2","price":1869.55,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Sungrow40kW-1_27229674-436c-42ca-98db-7e9f68c73611.png?v=1777795075"},{"product_id":"sungrow-sg50cx-p2-50kw-commercial-3-phase-inverter","title":"Sungrow SG50CX-P2 50kW Commercial 3-Phase Inverter","description":"\u003cdiv style=\"font-size: 16px; line-height: 1.6;\"\u003e\n\u003c!-- A. Product Title \/ Heading --\u003e\n\u003ch1 style=\"text-align: center;\"\u003eSungrow SG50CX-P2 50 kW 3‑Phase Commercial Solar Inverter\u003c\/h1\u003e\n\u003c!-- B. Key value proposition --\u003e\n\u003cul\u003e\n\u003cli\u003e50 kW 3‑phase inverter for commercial and industrial PV systems up to 70 kWp, ideal for warehouses, logistics hubs and small solar farms\u003c\/li\u003e\n\u003cli\u003eFour independent MPPTs with two strings each for flexible string design and better yield on complex roofs\u003c\/li\u003e\n\u003cli\u003eIP66, C5‑rated enclosure, integrated DC and AC surge protection and AFCI for reliable operation in tough UK and coastal environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- C. Brief Description --\u003e\n\u003cp\u003eThe Sungrow SG50CX‑P2 is a 50 kW three‑phase string inverter designed for 1000 V DC commercial solar arrays up to 70 kWp. It suits rooftop and ground‑mount systems on logistics centres, factories, offices and agricultural sites where dependable output and straightforward operation matter more than bells and whistles. With high efficiency, strong grid support features and robust environmental protection, it is a practical choice for long‑term PV generation on 230\/400 V three‑phase supplies.\u003c\/p\u003e\n\u003c!-- D. Key features --\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRated AC power 50 kW with up to 55 kVA apparent power for strong export capability on three‑phase grids\u003c\/li\u003e\n\u003cli\u003eFour MPPT inputs, two strings per MPPT (total eight strings) for good performance on roofs with multiple orientations or partial shading\u003c\/li\u003e\n\u003cli\u003eHigh max efficiency of 98.5 % and European efficiency of 98.3 % to minimise conversion losses\u003c\/li\u003e\n\u003cli\u003eIntegrated DC Type I+II and AC Type II surge protection, AFCI and built‑in PID recovery to help protect modules and wiring\u003c\/li\u003e\n\u003cli\u003eIP66, C5 anti‑corrosion housing with smart forced‑air cooling for outdoor wall‑mounted installation up to 4000 m altitude\u003c\/li\u003e\n\u003cli\u003eSupports G99 grid compliance and advanced grid support functions including LVRT, HVRT, active and reactive power control and ramp‑rate control, suitable for UK commercial connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- E. Technical specifications --\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003ch3\u003eDC input\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRecommended max. PV input power: 70 kWp\u003c\/li\u003e\n\u003cli\u003eMax. PV input voltage: 1100 V DC*\u003c\/li\u003e\n\u003cli\u003eMin. PV input voltage \/ start‑up voltage: 160 V DC \/ 200 V DC\u003c\/li\u003e\n\u003cli\u003eRated PV input voltage: 600 V DC\u003c\/li\u003e\n\u003cli\u003eMPPT operating voltage range: 160 V to 1000 V DC**\u003c\/li\u003e\n\u003cli\u003eNumber of independent MPPT inputs: 4\u003c\/li\u003e\n\u003cli\u003eNumber of PV strings per MPPT: 2\u003c\/li\u003e\n\u003cli\u003eMax. PV input current: 120 A (30 A × 4)\u003c\/li\u003e\n\u003cli\u003eMax. DC short‑circuit current: 160 A (40 A × 4)\u003c\/li\u003e\n\u003cli\u003eMax. current for DC connector: 30 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAC output\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated AC output power: 50 kW\u003c\/li\u003e\n\u003cli\u003eMax. AC output apparent power: 55 kVA\u003c\/li\u003e\n\u003cli\u003eMax. AC output current: 83.6 A\u003c\/li\u003e\n\u003cli\u003eRated AC output current (at 230 V phase‑neutral): 72.5 A\u003c\/li\u003e\n\u003cli\u003eRated AC voltage: 3 \/ N \/ PE, 220 \/ 380 V, 230 \/ 400 V\u003c\/li\u003e\n\u003cli\u003eAC voltage range: 312 V to 480 V\u003c\/li\u003e\n\u003cli\u003eRated grid frequency: 50 Hz \/ 60 Hz\u003c\/li\u003e\n\u003cli\u003eGrid frequency range: 45 Hz – 55 Hz \/ 55 Hz – 65 Hz\u003c\/li\u003e\n\u003cli\u003eHarmonic distortion (THD): \u0026lt; 3 % at rated power\u003c\/li\u003e\n\u003cli\u003ePower factor at rated power \/ adjustable range: \u0026gt; 0.99 \/ 0.8 leading to 0.8 lagging\u003c\/li\u003e\n\u003cli\u003eFeed‑in phases \/ AC connection: 3 \/ 3‑N‑PE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEfficiency\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMax. efficiency: 98.5 %\u003c\/li\u003e\n\u003cli\u003eEuropean efficiency: 98.3 %\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProtection and monitoring\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGrid monitoring: yes\u003c\/li\u003e\n\u003cli\u003eDC reverse polarity protection: yes\u003c\/li\u003e\n\u003cli\u003eAC short‑circuit protection: yes\u003c\/li\u003e\n\u003cli\u003eLeakage current protection: yes\u003c\/li\u003e\n\u003cli\u003eSurge protection: DC Type I+II \/ AC Type II\u003c\/li\u003e\n\u003cli\u003eGround fault monitoring: yes\u003c\/li\u003e\n\u003cli\u003eIntegrated DC switch: yes\u003c\/li\u003e\n\u003cli\u003ePV string current monitoring: yes\u003c\/li\u003e\n\u003cli\u003eArc fault circuit interrupter (AFCI): yes\u003c\/li\u003e\n\u003cli\u003ePID recovery function: yes\u003c\/li\u003e\n\u003cli\u003eOptimizer compatibility: optional (consult Sungrow for details)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGeneral data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions (W × H × D): 645 mm × 575 mm × 245 mm\u003c\/li\u003e\n\u003cli\u003eWeight: 41 kg\u003c\/li\u003e\n\u003cli\u003eMounting method: wall‑mounting bracket\u003c\/li\u003e\n\u003cli\u003eTopology: transformerless\u003c\/li\u003e\n\u003cli\u003eDegree of protection: IP66\u003c\/li\u003e\n\u003cli\u003eNight power consumption: \u0026lt; 5 W\u003c\/li\u003e\n\u003cli\u003eCorrosion category: C5\u003c\/li\u003e\n\u003cli\u003eOperating ambient temperature range: −30 °C to 60 °C\u003c\/li\u003e\n\u003cli\u003eAllowable relative humidity (non‑condensing): 0 % to 100 %\u003c\/li\u003e\n\u003cli\u003eCooling method: smart forced‑air cooling\u003c\/li\u003e\n\u003cli\u003eMax. operating altitude: 4000 m\u003c\/li\u003e\n\u003cli\u003eDisplay: LED, Bluetooth + app\u003c\/li\u003e\n\u003cli\u003eCommunication: RS485 \/ optional WLAN, Ethernet\u003c\/li\u003e\n\u003cli\u003eDC connection type: Evo2 (max. 6 mm²)\u003c\/li\u003e\n\u003cli\u003eAC connection type: OT terminal (16–35 mm²) or OT\/DT terminal (35–50 mm²)\u003c\/li\u003e\n\u003cli\u003eAC cable specification: outside diameter 18 mm – 38 mm\u003c\/li\u003e\n\u003cli\u003eGrid compliance: IEC 62109, IEC 61727, IEC 62116, VDE‑AR‑N 4105:2018, IEC 61000‑6‑3, EN 50549‑1, CEI 0‑21 2019, CEI 0‑16 2019, VDE 0126‑1‑1\/A1 VFR 2019, UTE C15‑712‑1:2013, UNE 206007‑1\/RD 1699, UNE 217002, G99, IEC 63027\u003c\/li\u003e\n\u003cli\u003eGrid support functions: Q‑at‑night, LVRT, HVRT, active and reactive power control, power ramp‑rate control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- F. Shipping \u0026 Support --\u003e\n\u003ch2\u003eShipping and installation\u003c\/h2\u003e\n\u003cp\u003eShipping is available to the UK, Ireland, Africa, the Caribbean and worldwide. If a shipping rate is not shown at checkout, please contact us on +44 2080 640335 or \u003ca href=\"mailto:info@energian.co.uk\"\u003einfo@energian.co.uk\u003c\/a\u003e for a tailored quote.\u003c\/p\u003e\n\u003cp\u003eThis is a grid‑connected commercial inverter and is not a plug‑and‑play product. We recommend installation and commissioning by one of our trusted solar partners or a suitably qualified electrician familiar with G99 requirements.\u003c\/p\u003e\n\u003ch2\u003eUK expert support\u003c\/h2\u003e\n\u003cp\u003eEnergian provides UK‑based technical support for Sungrow inverters. If you have any questions about system design, grid connection, or compatibility with your PV modules and protection devices, contact us by phone, email or live chat, or visit our office for an in‑person consultation.\u003c\/p\u003e\n\u003c!-- Documents section --\u003e\n\u003ch2\u003eDocuments available for download\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca rel=\"noopener\" style=\"color: rgb(43, 0, 255);\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/sungrow_user_manual-sg30_33_40_50cx_v14.pdf?v=1777629352\" target=\"_blank\"\u003eSungrow SG36\/40\/50CX‑P2 datasheet (PDF)\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca rel=\"noopener\" style=\"color: rgb(43, 0, 255);\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Sungrow_User_Manual-SG25_30_33_36_40_50CX-P2.pdf?v=1777733327\" target=\"_blank\"\u003eSungrow SG25\/30\/33\/36\/40\/50CX‑P2 user manual (PDF)\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/sungrow_installation_guide-sg30_33_40_50cx.pdf?v=1777628814\" target=\"_blank\"\u003eSungrow \u003cspan style=\"color: rgb(43, 0, 255);\"\u003eSG36\/40\/50CX‑P2 \u003c\/span\u003eInstallation Guide (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Sungrow","offers":[{"title":"Default Title","offer_id":57360423616894,"sku":"SG50CX-P2","price":2254.28,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Sungrow-50kW-1.png?v=1777794797"},{"product_id":"sungrow-sg125cx-p2-125kw-commercial-3-phase-inverter","title":"Sungrow SG125CX-P2 125kW Commercial 3-Phase Inverter","description":"\u003cdiv style=\"font-size: 16px; line-height: 1.6;\"\u003e\n\u003c!-- A. Product Title \/ Heading --\u003e\n\u003ch1 style=\"text-align: center;\"\u003eSungrow SG125CX‑P2 125 kW 3‑Phase Commercial Solar Inverter\u003c\/h1\u003e\n\u003c!-- B. Key value proposition --\u003e\n\u003cul\u003e\n\u003cli\u003e125 kW three‑phase inverter for large commercial and industrial PV systems up to 175 kW DC, ideal for logistics centres, warehouses and ground‑mount arrays.\u003c\/li\u003e\n\u003cli\u003e12 independent MPPTs with two strings each for highly flexible string design and strong performance on complex or partially shaded sites.\u003c\/li\u003e\n\u003cli\u003eIP66, C5‑rated enclosure with integrated DC\/AC surge protection and AFCI 2.0 support for reliable outdoor operation in harsh and coastal environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- C. Brief Description --\u003e\n\u003cp\u003eThe Sungrow SG125CX‑P2 is a 125 kW three‑phase string inverter for 1000 V DC commercial and industrial solar systems up to 175 kW of PV modules. It suits large rooftops and mid‑scale ground‑mount projects on logistics hubs, factories, cold stores and depots where dependable output, grid support and straightforward servicing are key. With 12 MPPTs, high efficiency and robust protection, it provides a practical backbone for multi‑string PV systems connected to 230\/400 V three‑phase supplies.\u003c\/p\u003e\n\u003c!-- D. Key features --\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e12 MPPTs, each supporting two strings, for fine‑grained string layout and better yield across mixed orientations and shading conditions.\u003c\/li\u003e\n\u003cli\u003eMax. efficiency 98.5 % and European efficiency 98.3 %, helping to minimise conversion losses on high‑capacity arrays.\u003c\/li\u003e\n\u003cli\u003eDynamic shading optimisation mode plus smart IV‑curve diagnosis and grid fault recording for easier remote monitoring and O\u0026amp;M.\u003c\/li\u003e\n\u003cli\u003eCompatible with aluminium AC cables up to 240 mm² and drawer‑style cable sealing plate to support AC cable pre‑assembly.\u003c\/li\u003e\n\u003cli\u003eIntegrated DC Type I+II and AC Type II surge protection, AFCI 2.0 support, IP66 and C5 anti‑corrosion rating for long‑term outdoor use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- E. Technical specifications --\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003ch3\u003eDC input\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRecommended max. PV input power: 175 kW.\u003c\/li\u003e\n\u003cli\u003eMax. PV input voltage: 1100 V DC.\u003c\/li\u003e\n\u003cli\u003eMin. PV input voltage \/ start‑up input voltage: 180 V DC \/ 200 V DC.\u003c\/li\u003e\n\u003cli\u003eRated PV input voltage: 600 V DC.\u003c\/li\u003e\n\u003cli\u003eMPP voltage range: 180 V – 1000 V DC.\u003c\/li\u003e\n\u003cli\u003eNumber of independent MPP inputs: 12.\u003c\/li\u003e\n\u003cli\u003eNumber of PV strings per MPPT: 2.\u003c\/li\u003e\n\u003cli\u003eMax. PV input current: 360 A (30 A × 12).\u003c\/li\u003e\n\u003cli\u003eMax. DC short‑circuit current: 480 A (40 A × 12).\u003c\/li\u003e\n\u003cli\u003eMax. current for DC connector: 20 A.\u003c\/li\u003e\n\u003cli\u003eDC 15 A current input per string, compatible with over 500 W+ PV modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAC output\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMax. AC output power: 125 kVA.\u003c\/li\u003e\n\u003cli\u003eRated AC output apparent power: 125 kVA.\u003c\/li\u003e\n\u003cli\u003eMax. AC output current: 181.1 A.\u003c\/li\u003e\n\u003cli\u003eRated AC output current (at 230 V phase‑neutral): 181.1 A.\u003c\/li\u003e\n\u003cli\u003eRated AC voltage: 3 \/ N \/ PE, 230 \/ 400 V.\u003c\/li\u003e\n\u003cli\u003eAC voltage range: 320 V – 480 V.\u003c\/li\u003e\n\u003cli\u003eRated grid frequency: 50 Hz \/ 60 Hz.\u003c\/li\u003e\n\u003cli\u003eGrid frequency range: 45 – 55 Hz \/ 55 – 65 Hz.\u003c\/li\u003e\n\u003cli\u003eHarmonic (THD): \u0026lt; 3 % at rated power.\u003c\/li\u003e\n\u003cli\u003ePower factor at rated power \/ adjustable power factor: \u0026gt; 0.99 \/ 0.8 leading – 0.8 lagging.\u003c\/li\u003e\n\u003cli\u003eFeed‑in phases \/ connection phases: 3 \/ 3‑N‑PE.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEfficiency\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMax. efficiency: 98.5 %.\u003c\/li\u003e\n\u003cli\u003eEuropean efficiency: 98.3 %.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProtection and monitoring\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGrid monitoring: yes.\u003c\/li\u003e\n\u003cli\u003eDC reverse‑polarity protection: yes.\u003c\/li\u003e\n\u003cli\u003eAC short‑circuit protection: yes.\u003c\/li\u003e\n\u003cli\u003eLeakage current protection: yes.\u003c\/li\u003e\n\u003cli\u003eSurge protection: DC Type I+II \/ AC Type II.\u003c\/li\u003e\n\u003cli\u003eGround fault monitoring: yes.\u003c\/li\u003e\n\u003cli\u003eDC switch: yes.\u003c\/li\u003e\n\u003cli\u003ePV string monitoring: yes.\u003c\/li\u003e\n\u003cli\u003eQ‑at‑night function: yes.\u003c\/li\u003e\n\u003cli\u003eArc fault circuit interrupter (AFCI): yes.\u003c\/li\u003e\n\u003cli\u003ePID recovery function: yes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGeneral data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions (W × H × D): 1020 × 795 × 360 mm.\u003c\/li\u003e\n\u003cli\u003eMounting method: wall‑mounting bracket.\u003c\/li\u003e\n\u003cli\u003eWeight: 87 kg.\u003c\/li\u003e\n\u003cli\u003eTopology: transformerless.\u003c\/li\u003e\n\u003cli\u003eDegree of protection: IP66.\u003c\/li\u003e\n\u003cli\u003eCorrosion category: C5.\u003c\/li\u003e\n\u003cli\u003eNight power consumption: \u0026lt; 5 W.\u003c\/li\u003e\n\u003cli\u003eOperating ambient temperature range: −30 °C to 60 °C.\u003c\/li\u003e\n\u003cli\u003eAllowable relative humidity range (non‑condensing): 0 % – 100 %.\u003c\/li\u003e\n\u003cli\u003eCooling method: smart forced‑air cooling.\u003c\/li\u003e\n\u003cli\u003eMax. operating altitude: 4000 m (derating above 3000 m).\u003c\/li\u003e\n\u003cli\u003eDisplay: LED, Bluetooth + app.\u003c\/li\u003e\n\u003cli\u003eCommunication: RS485 \/ optional WLAN, Ethernet.\u003c\/li\u003e\n\u003cli\u003eDC connection type: Evo2 (max. 6 mm²).\u003c\/li\u003e\n\u003cli\u003eAC connection type: OT \/ DT terminal (max. 240 mm²).\u003c\/li\u003e\n\u003cli\u003eGrid compliance: IEC 62109‑1, EN\/IEC 61000‑6‑1\/2\/3\/4, IEC 61727, IEC 62116, EN 50549‑1\/2, UTE C15‑712‑1, VDE V 0126‑1‑1, VDE‑AR‑N 4105:2018, VFR 2019, NC RfG, G99, UNE 217002, NTS, CEI 0‑21 2019, CEI 0‑16 2019, NRS‑097‑2‑1.\u003c\/li\u003e\n\u003cli\u003eGrid support: Q‑at‑night function, LVRT, HVRT, active and reactive power control, power ramp‑rate control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- F. Shipping \u0026 Support --\u003e\n\u003ch2\u003eShipping and installation\u003c\/h2\u003e\n\u003cp\u003eShipping is available to the UK, Ireland, Africa, the Caribbean and worldwide. If a shipping rate is not shown at checkout, please contact us on +44 2080 640335 or \u003ca href=\"mailto:info@energian.co.uk\"\u003einfo@energian.co.uk\u003c\/a\u003e for a tailored quote.\u003c\/p\u003e\n\u003cp\u003eThis is a high‑power grid‑connected commercial inverter and is not a plug‑and‑play product. We recommend installation and commissioning by one of our trusted solar partners or a suitably qualified electrician experienced with G99 and commercial three‑phase systems.\u003c\/p\u003e\n\u003ch2\u003eUK expert support\u003c\/h2\u003e\n\u003cp\u003eEnergian provides UK‑based technical support for Sungrow commercial inverters. If you need help with system design, protection coordination, grid connection studies or compatibility with your PV modules and switchgear, contact us by phone, email or live chat, or visit our office for an in‑person consultation.\u003c\/p\u003e\n\u003c!-- Documents section --\u003e\n\u003ch2\u003eDocuments available for download\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/sungrow_datasheet_sg125cx-p2_v12.pdf?v=1777796170\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eSungrow SG125CX‑P2 datasheet (PDF)\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/instructions-for-installation-of-industrial-and-commercial-inverters-in-different-scenarios-v12-en.pdf?v=1777796859\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" target=\"_blank\"\u003eSungrow SG125CX‑P2 installation guide (PDF)\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/sg125-110-75cx-p2-uen-ver15.pdf?v=1777797267\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eSungrow SG125CX‑P2 user manual (PDF)\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- Suggested alt text \u0026 meta (for Shopify fields) --\u003e\n\u003c\/div\u003e","brand":"Sungrow","offers":[{"title":"Default Title","offer_id":57360430727550,"sku":"SG125CX-P2","price":4249.09,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Sungrow-125kW-1.png?v=1777797570"},{"product_id":"sungrow-sbh-5kwh-stackable-high-voltage-battery-module","title":"Sungrow SBH 5kWh Stackable High Voltage Battery","description":"\u003cdiv style=\"font-size: 16px; line-height: 1.6;\"\u003e\n\u003c!-- A. Product Title \/ Heading --\u003e\n\u003ch1 style=\"text-align: center;\"\u003e\u003cstrong\u003eSungrow SBH 5kWh Stackable High Voltage Battery Module\u003c\/strong\u003e\u003c\/h1\u003e\n\u003c!-- B. Key value proposition --\u003e\n\u003cul\u003e\n\u003cli\u003e5kWh high voltage LiFePO4 battery module for building 10–40kWh Sungrow SBH100–400 stacks to support commercial and industrial backup, peak shaving and self-consumption.\u003c\/li\u003e\n\u003cli\u003eStackable, plug-in design with no inter-module cabling for fast on-site installation and easy future expansion.\u003c\/li\u003e\n\u003cli\u003eHigh usable energy with up to 100% depth of discharge and multi-stage protection for long service life and safety.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- C. Brief Description --\u003e\n\u003cp\u003eThe Sungrow SBH 5kWh Stackable High Voltage Battery Module is the building block of the SBH100–400 series, allowing you to assemble 10–40kWh high voltage battery stacks for three-phase hybrid systems. Each 5kWh LiFePO4 module locks mechanically into the base and neighbouring modules, providing a neat, floor-standing solution for logistics hubs, light industrial sites and commercial buildings that need reliable battery storage alongside Sungrow hybrid inverters.\u003c\/p\u003e\n\u003c!-- D. Key features --\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e5kWh lithium iron phosphate (LiFePO4) prismatic cell module forming part of 10–40kWh high voltage stacks.\u003c\/li\u003e\n\u003cli\u003eUp to 50A continuous charge\/discharge current per stack, with 8 modules delivering system power up to 28kW.\u003c\/li\u003e\n\u003cli\u003eUp to 100% usable energy with settable depth of discharge for project-specific requirements.\u003c\/li\u003e\n\u003cli\u003ePlug-and-play stacking concept: no separate DC cables needed between battery modules.\u003c\/li\u003e\n\u003cli\u003eFloor-standing, IP55-rated system suitable for indoor and outdoor installations in commercial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- E. Technical specifications --\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003ch3\u003eSystem data (SBH100–400 stack)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBattery type: LiFePO4 Prismatic Cell.\u003c\/li\u003e\n\u003cli\u003eBattery module: 5.0kWh, 45kg.\u003c\/li\u003e\n\u003cli\u003eMax. charging\/discharging current (continuous): 50A.\u003c\/li\u003e\n\u003cli\u003eDepth of discharge: Max. 100% DOD (settable).\u003c\/li\u003e\n\u003cli\u003eShort circuit current: 3500A.\u003c\/li\u003e\n\u003cli\u003eDisplay: SOC indicator, Status indicator.\u003c\/li\u003e\n\u003cli\u003eCommunication interface: CAN.\u003c\/li\u003e\n\u003cli\u003eProtection – over\/under voltage protection: Yes.\u003c\/li\u003e\n\u003cli\u003eProtection – over current protection: Yes.\u003c\/li\u003e\n\u003cli\u003eProtection – over\/under temperature protection: Yes.\u003c\/li\u003e\n\u003cli\u003eProtection – DC breaker: Yes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStack configurations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBattery stack from 10kWh to 40kWh consists of 2-8 modules and \u003c\/li\u003e\n\u003cli\u003eSBH100 – 2 modules, 10.0kWh usable energy, 140.8V nominal voltage, 7.04kW rated DC power, operating voltage 118.8V–160.6V, dimensions 675 × 580 × 350mm, weight 106kg.\u003c\/li\u003e\n\u003cli\u003eSBH150 – 3 modules, 15.0kWh usable energy, 211.2V nominal voltage, 10.56kW rated DC power, operating voltage 178.2V–240.9V, dimensions 675 × 740 × 350mm, weight 151kg.\u003c\/li\u003e\n\u003cli\u003eSBH200 – 4 modules, 20.0kWh usable energy, 281.6V nominal voltage, 14.08kW rated DC power, operating voltage 237.6V–321.2V, dimensions 675 × 900 × 350mm, weight 196kg.\u003c\/li\u003e\n\u003cli\u003eSBH250 – 5 modules, 25.0kWh usable energy, 352.0V nominal voltage, 17.60kW rated DC power, operating voltage 297V–401.5V, dimensions 675 × 1060 × 350mm, weight 241kg.\u003c\/li\u003e\n\u003cli\u003eSBH300 – 6 modules, 30.0kWh usable energy, 422.4V nominal voltage, 21.12kW rated DC power, operating voltage 356.4V–481.8V, dimensions 675 × 1220 × 350mm, weight 286kg.\u003c\/li\u003e\n\u003cli\u003eSBH350 – 7 modules, 35.0kWh usable energy, 492.8V nominal voltage, 24.64kW rated DC power, operating voltage 415.8V–562.1V, dimensions 675 × 1380 × 350mm, weight 331kg.\u003c\/li\u003e\n\u003cli\u003eSBH400 – 8 modules, 40.0kWh usable energy, 563.2V nominal voltage, 28.16kW rated DC power, operating voltage 475.2V–642.4V, dimensions 675 × 1540 × 350mm, weight 376kg.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGeneral data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstallation location: Indoor \/ Outdoor.\u003c\/li\u003e\n\u003cli\u003eMounting method: Floor stand.\u003c\/li\u003e\n\u003cli\u003eOperating ambient temperature range: Charge: 0°C – 50°C; Discharge: −20°C – 50°C.\u003c\/li\u003e\n\u003cli\u003eDegree of protection: IP55.\u003c\/li\u003e\n\u003cli\u003eAllowable relative humidity range: 0% – 95% non-condensing.\u003c\/li\u003e\n\u003cli\u003eMax. operating altitude: Max. 2000m.\u003c\/li\u003e\n\u003cli\u003eCooling method: Natural convection.\u003c\/li\u003e\n\u003cli\u003eCertificates: CE, CEC, IEC 62619, IEC 62040, UN 38.3, VDE 2510-50, IEC 62477, IEC 63056.\u003c\/li\u003e\n\u003cli\u003eWarranty: 10 Years (refer to battery warranty letter for conditional application).\u003c\/li\u003e\n\u003cli\u003eTest conditions for ratings: 25°C, 100% depth of discharge (DOD), 0.2C charge and discharge.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- F. Shipping and UK support --\u003e\n\u003ch2\u003eShipping and UK expert support\u003c\/h2\u003e\n\u003cp\u003eShipping is available to the UK, Ireland, Africa, the Caribbean and worldwide. If the shipping rate is not shown at checkout, please contact us on +44 2080640335 or \u003ca href=\"mailto:info@energian.co.uk\"\u003einfo@energian.co.uk\u003c\/a\u003e for a quote.\u003c\/p\u003e\n\u003cp\u003eThe Sungrow SBH 5kWh stackable high voltage battery module is designed to be installed as part of a matched Sungrow SBH100–400 system and compatible hybrid inverter. Energian recommends installation and commissioning by a suitably qualified electrician or trusted installer partner to meet UK wiring regulations and manufacturer requirements.\u003c\/p\u003e\n\u003cp\u003eUK expert support is available – contact us by phone, email or live chat, or visit our office for in-person consultation on system design, battery sizing, Sungrow hybrid inverter pairing and project integration for logistics, commercial and industrial sites.\u003c\/p\u003e\n\u003ch2\u003eDocuments available for download\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca rel=\"noopener\" style=\"color: rgb(43, 0, 255);\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Sungrow_HV_Battery_SBH100-400_Datasheet_-_26_02_2024_1_48e79275-979b-4bd7-a544-a08ba23f227f.pdf?v=1778404350\" target=\"_blank\"\u003eSungrow SBH100–400 High Voltage LFP Battery – Datasheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca rel=\"noopener\" style=\"color: rgb(43, 0, 255);\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/Sungrow_HV_SBH100-400_User_Manual_-_13_05_2025_fd94ba69-6500-4c19-8313-d64844cfcb7d.pdf?v=1778404514\" target=\"_blank\"\u003eSungrow SBH100–400 High Voltage Battery – User Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Sungrow","offers":[{"title":"Default Title","offer_id":57388398444926,"sku":null,"price":4989.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/SungrowSBH5.0kWhBatteryModule.jpg?v=1778404737"}],"url":"https:\/\/www.energian.co.uk\/collections\/sungrow.oembed","provider":"Energian","version":"1.0","type":"link"}